12
© by N&W GLOBAL VENDING SpA
07 06 274 -00
INITIALISING
When the “Initialise” function is displayed the vending
machine can be initialised restoring all default data.
This function should be used the first time the machine is
switched on and in the event of a memory data error or
reprogramming of the board.
All statistic information will be reset.
Press the confirm button “ ” to display the message
“Confirm?”. Press the button “ ” again to display the first
variable parameter to define the machine configuration.
The available options (blinking) can be scrolled with the
“ ” and “ ” buttons, the selection is confirmed with button
“ ” and the next parameter is presented. When pressing
button “ ” after the last parameter the display will show the
message “Working” for a few seconds and the machine is
initialised.
The parameters are as follows:
“Country”
Type of doses to be
used for the selections
“Layout”
Layout of containers and
selection menu from the
available ones
“Tank”
Water supply from the mains
or from a tank
N.B.:
When the machine is switched on for the first time or
in any case after initialising, as well as the list of controls
to be performed, also the language used for the messages
on the display is proposed.
The available languages can be scrolled with the “ ” and
“ ” buttons, and the selection is confirmed with button “ ”.
Unless the machine is initialised, the language request is
not made again.
In any case it will be possible to change it through the
specific function in the “Technician” menu.
FILLING THE WATER SYSTEM
If the machine is connected to the water mains, when it is
switched on the conditions of air-break (full or empty),
pump and boiler priming (pressure) are checked.
If required by the conditions, the machine will automati-
cally start an installation cycle, and namely:
- the message “Installation” will be shown on the display
for the entire duration of the cycle;
- the water mains solenoid valve is opened or the pump
is started to fill the air-break;
- the milk solenoid valve is opened so that the air may
be bled from the boiler and from the hydraulic system,
and 400 cc. of water filled.
N.B.:
If there is no water flow from the mains during the installa-
tion cycle, the machine will stop until water is resumed or the
machine is switched off.
IMPORTANT NOTICE!!!
If a considerable amount of air bubbles is formed in the
water system, for example during maintenance, it is pos-
sible that an installation cycle is automatically started
when the machine is switched on.
Versions with internal tank
For models with an internal tank, when the machine is
first switched on, the installation procedure MUST BE
carried out manually (see relevant chapter).
Содержание Korinto UL
Страница 2: ......
Страница 4: ......
Страница 49: ...by N W GLOBAL VENDING SpA NOTE...
Страница 50: ...N W GLOBAL VENDING S P A Sx44100...
Страница 51: ...Korinto ES UL 120V...
Страница 52: ...by N W GLOBAL VENDING SpA NOTE...
Страница 53: ...by N W GLOBAL VENDING SpA NOTE...
Страница 54: ...by N W GLOBAL VENDING SpA NOTE...
Страница 56: ......