Configure Outgoing Calls
28
XN120 Voice Over IP Card Guide
To configure the XN120 routing table:
Program 10-23-01
There are 1000 DDI entries.
One entry is required for each
remote destination.
System Interconnection. This
switches on or off the specified
table entry.
The IP address is the address
of the remote destination. If
this is another XN120 system,
this IP address should be the
one assigned to its EXIFU-A1
Ethernet port.
The Call Control Port cannot
be changed.
The dialed digits should be
sufficient to correctly identify
the remote site.
For example, if you have
several XN120 systems with
numbering plans:
012xxx (London)
011xxx (Rome)
023xxx (Dublin)
you would need to specify at
least three digits, otherwise
the XN120 would not know
which destination to send calls
beginning with 01 to.
Ø
Select the correct table entry number 1-1000 with the Vol.
p
q
keys.
Ø
Press 1 to enable this table entry
Ø
Press HOLD to confirm the entry and step to the next option.
Ø
Enter the IP Address, you must enter three digits for each field.
Example 172 016 000 010 you do not need to enter the
decimal points.
Ø
Press HOLD to confirm the entry and step to the next option.
Ø
Press HOLD to step to the next option (it is not possible to
change this item)
Ø
Enter the dialed digits. This should be enough digits to identify
the destination.
Ø
Press HOLD to confirm the entry and step to the next table
entry. Repeat the above steps until all required entries are
complete.
Ø
Press DC several times when you are done to return to the
Program Mode.
(Press SPK to save changes and exit if you are finished).
10-03-01 No.1
SysInterconnect0
Press Vol
p
q
to select the
entry number
10-03-02 No.1
0. 0. 0. 0
10-03-03 No.1
CallCTRPort 1720
10-03-03 No.1
Dial