background image

Test IP Connectivity 

 

12 

 

 

 

     XN120 Voice Over IP Card Guide 

 
10- Test IP Connectivity 

 
Once the VOIP card and EXIFU-A1 Ethernet ports have been configured and connected to the Data Network 
you should test connectivity. 
 

Test 1 – Layer 1 Lamp. 

Each Ethernet port has two lamps next to the RJ45 connector to indicate the status of the port. 

! This is a basic confirmation that the connection is made, it does not necessarily mean that the circuit is 
working fully. 

 
The orange link LED indicates that there is a Layer 1 link with the Ethernet hub/switch.  This should be on when 
a connection is present. 
 
The green activity LED indicates Ethernet activity.  Every frame that is transmitted or received by the Ethernet 
port will cause the activity LED to light temporarily.  When calls are in progress, or on a busy Ethernet network 
you will notice that this LED is lit almost constantly. 
 
 
 
 

 

 

Test 2 – PING. 

If there is a layer 1 connection and the IP details are correct, it should be possible to “ping” the VOIPU card and 
the EXIFU-A1 Ethernet port.  PING (Packet InterNet Groper) is a standard utility that is run from a PC that 
sends a small packet of data to a specified IP address.  When the “ping” is received, the receiving device 
returns the data to the sender.  The original sender can then determine if the device is available on the network 
and can indicate the network delay between the two endpoints. 
 
To ping from a Microsoft Windows PC (method may vary slightly dependant on Operating system): 
 

· 

Ensure the PC has a valid IP address and is connected to the data network 

· 

Click on the Start button 

· 

Click on Run… 

· 

Type cmd in the Open dialogue box and click OK.  A command prompt window will open. 

· 

Type ping 172.16.0.10 (replace 172.16.0.10 with the actual IP address that you want to test) and then 
press Enter. 

 

Activity LED        Link LED  

Содержание XN120 Vision

Страница 1: ...supplied for future reference Regulatory Notice Refer to the Getting Started Guide 991409 5 supplied with the XN120 Main Unit for the Declaration of Conformity related to the product Warning This is...

Страница 2: ...IP Addresses 10 10 Test IP Connectivity 12 11 Configure SIP Trunks 14 12 Configure Incoming Calls 17 Non DDI Operation 17 DDI Operation 19 Set the VOIPU lines as DDI Mode 20 Assign each VOIPU line to...

Страница 3: ...y recommended that you consult the NEC Infrontia Voice Over IP Reference Manual 991451 5 before attempting this XN120 VOIPU Cards Available Each XN120 VOIPU card has 4 Digital Signal Processors DSP on...

Страница 4: ...port only even if a VOIPUDB is installed This port is used to transmit receive the IP packets for all calls active on the card Each VOIPU card and the Ethernet port on the EXIFU A1 connects to an Ethe...

Страница 5: ...EXIFU A1 if not already installed 5 Fit the 2OPBOX if not already installed 6 Install the VOIPU card s into the 2OPBOX 7 Connect the VOIPU cards and EXIFU A to the data network 8 Power on the XN120 9...

Страница 6: ...rom its packaging and locate the black 40 pin connector on the PCB CN11 on the VOIPU and CN6 on the Daughterboard Gently place the daughterboard onto the VOIPU so that the 4 plastic legs locate into t...

Страница 7: ...the XN120 unit s A VOIPU will use 4 of the XN120 s trunk ports A VOIPU with a VOIPUDB installed will use 8 of the XN120 s trunk ports If there are not sufficient trunks ports available on the system...

Страница 8: ...Cable CAT5 or better Straight Cross Ethernet Cable The connections of the Ethernet cable depend on the device that you connect When connecting to an Ethernet hub you would normally use a straight cabl...

Страница 9: ...the MOH Page connector on the main unit refer to the Getting Started Guide supplied with the XN120 for further information 2 The VOIPU card s will be automatically configured Check the VOIPU card s ha...

Страница 10: ...bnet Mask for the XN120 this must be specified by the Network Administrator responsible for the customers LAN 1 Program 10 12 01 Enter the IP Address of the XN120 system Enter the Subnet Mask You must...

Страница 11: ...Press DC several times when you are done to return to the Program Mode Press SPK to save changes and exit if you are finished Configuration Sheet IP Addresses Program 10 12 01 IP Address Program 10 12...

Страница 12: ...net network you will notice that this LED is lit almost constantly Test 2 PING If there is a layer 1 connection and the IP details are correct it should be possible to ping the VOIPU card and the EXIF...

Страница 13: ...s TTL 30 Ping statistics for 172 16 0 10 Packets Sent 4 Received 4 Lost 0 0 loss Approximate round trip times in milli seconds Minimum 0ms Maximum 1ms Average 0ms b Unsuccessful No reply is received t...

Страница 14: ...P Parameters The XN120 has several system wide settings that have to be programmed to enable SIP to work These items are located in Program 10 28 Setting CODEC Options The XN120 uses a CODEC Coder Dec...

Страница 15: ...is field does not have to be a valid domain name but it is recommended that the same domain name is used for all XN120 systems within the SIP network example mysipnetwork co uk Host Name This identifi...

Страница 16: ...Priority This is the CODEC that will be used for SIP Trunk Calls 0 G711 1 G723 2 G729 Default Setting G 711 Enter the CODEC Type to use for SIP Trunk calls Press DC several times when you are done to...

Страница 17: ...digits then the BRI lines can be routed in exactly the same way that you would route an analogue trunk Refer to the XN120 Getting Started Guide for more detail In brief Route each VOIPU line to an In...

Страница 18: ...g Ring Group Target 22 05 01 default all trunks point to IRG 1 Line Number Line Mode 22 02 01 default 0 normal 1 2 3 4 5 6 7 8 Members of the IRG Default telephone 200 1 2 3 4 5 6 7 8 9 10 11 12 13 14...

Страница 19: ...fied In brief Set each VOIPU line as DDI mode in Program 22 02 01 ensure you do this for all night modes You then place the lines into Trunk Groups in Program 14 05 01 route each Trunk Group to an are...

Страница 20: ...and exit if you are finished Assign each VOIPU line to a Trunk Group At default all lines are in Trunk Group number 1 All VOIPU trunks should be assigned to the same Trunk Group number Program 14 05...

Страница 21: ...each night mode in use by the customer For example during day mode the main DDI number routes to reception but in night mode the same DDI number must route to voice mail Program 22 13 01 Point the tru...

Страница 22: ...u can specify the operation when the target number is busy or ring no answer If the target number is busy you can either return busy tone to the incoming caller or overflow to an alternative target If...

Страница 23: ...entry number 1 2000 with the Vol p q keys Enter the DDI receive digits Press HOLD to confirm the entry and step to the next option Enter the target number Press HOLD to confirm the entry and step to...

Страница 24: ...Mode 22 02 01 DDI mode 3 default 0 normal Trunk Group Number 14 05 01 default 1 Point to DDI table area for each night mode 22 13 01 default all trunk groups point to area 1 1 2 3 4 5 6 7 8 1 2 3 4 5...

Страница 25: ...more than 50 DDI entries are required DDI entry number Receive digits 22 11 01 default entries 1 99 have 00 99 Target 22 11 02 default entries 1 99 have 200 299 Name 22 11 03 default blank Transfer O...

Страница 26: ...mber 1 If you have changed the Trunk Group number of the VOIPU lines in Program 14 05 01 you will also need to include the new trunk group number within the route used when 9 is dialed You can assign...

Страница 27: ...network there needs to be a method of translating dialed numbers to IP addresses these cannot be automatically determined as in the previous example The XN120 has a dialing table that is referred to...

Страница 28: ...n to send calls beginning with 01 to Select the correct table entry number 1 1000 with the Vol p q keys Press 1 to enable this table entry Press HOLD to confirm the entry and step to the next option E...

Страница 29: ...re entries are required up to 1000 entries can be used System Number System Interconnection PRG10 23 01 Yes No Destination IP Address PRG10 23 02 Call Control PRG10 23 03 Dial Number PRG10 23 02 1 2 3...

Страница 30: ...insertion of the prefix digits 0 for national calls and 00 for international calls This is enabled by Program 20 19 03 set this option to 1 to enable the insertion of the 0 or 00 prefix digits If the...

Страница 31: ...001 010 IP Address of remote system 10 23 04 Sys 1 3 2 Digits to associate with remote system 10 28 01 xn120 co uk SIP Domain Name 10 28 02 systema systemb SIP Host Name 10 28 04 200 300 UserID for s...

Страница 32: ...the system phone to select the program item and change its value etc The LCD display will show the current program item the editing point is shown by a flashing curser SPK Save changes and exit config...

Страница 33: ...o step on to the next if you did not make any changes to the entry Exiting Configuration Mode When you exit configuration mode your changes will be saved into the battery backed memory Until you exit...

Страница 34: ...Integrated Services Digital Network IETF Internet Engineering Task Force The IETF is an international community of network designers operators vendors and researchers whose purpose is to coordinate th...

Отзывы: