170 – Chapter 1
DRAFT 3
Automated Attendant No Answer Disconnect Time Selection, 1-4-03
December 2004
NEC Business Solutions Ltd
Doc.
No.: 8194 -
Release 2.0
Dece
mber 2004
1-4-03
System Mode
1
Submode
4
Data No.
03
PC Programming
+ AU
Automated Attendant No
Answer Disconnect Time
Selection
General Description
Use this Memory Block to establish how long the Automated Attendant rings a station before
automatically disconnecting the caller.
With IPK R2000 and above
, this memory block allows flexible entry.
For R2000 only.
For R2000 and above.
Display
Settings
LK 1
LK 2
LK 3
LK 4
The shaded area indicates
the default setting.
1 min.
2 min.
3 min.
4 min.
LK 5
LK 6
LK 7
LK 8
Programming Procedures
1
Go off-line.
2
Press LK1 + LK4 +
KC
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
4
Press
N
to write the data.
5
Press
P
to go back on-line.
Display
Programming Procedures
1
Go off-line.
2
Press LK1 + LK4 +
KC
to access the Memory Block.
0 3 : A A
D I S
2 m
T I M E
D I S P L A Y
Data
No.
Title
Setting
Data
0 3 : A A
D I S
1 2 0 S
T I M E
D I S P L A Y
Data
No.
Title
Setting
Data