E-27
TROUBLESHOOTING
This section helps you resolve problems you may encounter while setting up or using the projector.
Power Indicator
Indicator Condition
Projector Condition
Note
Off
Blinking light
Steady light
Green
Orange
0.5 sec On,
0.5 sec Off
0.5 sec On,
0.5 sec Off
The main power is off.
The projector is getting ready
to turn on.
The projector is cooling down.
The projector is turned on.
The projector is in Standby.
Green
Orange
–
Wait for a moment.
Wait for a moment.
–
–
Indicator Condition
Projector Condition
Note
Off
Blinking light
Steady light
Red
Green
Orange
1 cycle (0.5 sec On,
2.5 sec Off)
2 cycle (0.5 sec On,
0.5 sec Off)
4 cycle (0.5 sec On,
0.5 sec Off)
6 cycle (0.5 sec On,
0.5 sec Off)
Normal
Lamp cover error or lamp
housing error
Temperature error
Fan error
Lamp error
Re-firing the lamp
Control Panel key locked
–
Replace the lamp cover or
lamp housing correctly.
The projector is overheated.
Move the projector to a cooler
location.
Fans will not work correctly.
Lamp fails to light. Wait a full
minute and then turn on again.
The projector is re-firing.
You have pressed control
panel key when Control Panel
Key Lock is enabled.
Status Indicator
Indicator Condition
Projector Condition
Note
Off
Blinking light
Steady light
Normal
Lamp has reached its end of
life. Lamp replacement mes-
sage will be displayed.
Lamp has been used beyond
its limit. The projector will not
turn on until the lamp is re-
placed.
Red
Red
–
Replace the lamp.
Replace the lamp.
Lamp Indicator
Содержание VT46