Item
No.
Item
Input Data
Description
Default
Related
Program
25
Automatic Trans-
fer Setup for
Each Extension
Group
0~9,
*
, # Maximum of
4 digit (SL1000)
0~9,
*
, # Maximum of
8 digit (SL1100)
Terminal: MLT, SLT
702
20-11-17
24-05
26
Automatic Trans-
fer Cancellation
for Each Exten-
sion Group
0~9,
*
, # Maximum of
4 digit (SL1000)
0~9,
*
, # Maximum of
8 digit (SL1100)
Terminal: MLT, SLT
703
27
Destination of
Automatic Trans-
fer Each Exten-
sion Group
0~9,
*
, # Maximum of
4 digit (SL1000)
0~9,
*
, # Maximum of
8 digit (SL1100)
Terminal: MLT
704
20-11-17
24-05
28
Delayed Transfer
for Every Exten-
sion Group
0~9,
*
, # Maximum of
4 digit (SL1000)
0~9,
*
, # Maximum of
8 digit (SL1100)
Terminal: MLT, SLT
705
20-11-17
24-05
24-02-08
29
Delayed Transfer
Cancellation for
Each Extension
Group
0~9,
*
, # Maximum of
4 digit (SL1000)
0~9,
*
, # Maximum of
8 digit (SL1100)
Terminal: MLT, SLT
706
20-11-17
30
DND Setup for
Each Extension
Group
0~9,
*
, # Maximum of
4 digit (SL1000)
0~9,
*
, # Maximum of
8 digit (SL1100)
Terminal: MLT, SLT
707
31
DND Cancella-
tion for Each Ex-
tension Group
0~9,
*
, # Maximum of
4 digit (SL1000)
0~9,
*
, # Maximum of
8 digit (SL1100)
Terminal: MLT, SLT
708
33
Dial Block
0~9,
*
, # Maximum of
4 digit (SL1000)
0~9,
*
, # Maximum of
8 digit (SL1100)
Terminal: MLT, SLT
700
34
Temporary Toll
Restriction Over-
ride
0~9,
*
, # Maximum of
4 digit (SL1000)
0~9,
*
, # Maximum of
8 digit (SL1100)
Terminal: MLT, SLT
875
21-07
35
Pilot Group With-
drawing
0~9,
*
, # Maximum of
4 digit (SL1000)
0~9,
*
, # Maximum of
8 digit (SL1100)
Terminal: MLT, SLT
750
36
Toll Restriction
Override
0~9,
*
, # Maximum of
4 digit (SL1000)
0~9,
*
, # Maximum of
8 digit (SL1100)
Terminal: MLT, SLT
763
21-14
37
Ring Volume Set
0~9,
*
, # Maximum of
4 digit (SL1000)
0~9,
*
, # Maximum of
8 digit (SL1100)
Terminal: MLT
829
38
Programmable
Function Key
Programming (2-
Digit Service Co-
des)
0~9,
*
, # Maximum of
4 digit (SL1000)
0~9,
*
, # Maximum of
8 digit (SL1100)
Terminal: MLT
852
15-07
11-11-17
39
Station Speed Di-
al Number Entry
(V2.0 Added)
(SL1000)
0~9,
*
, # Maximum of
4 digit
Terminal: MLT, SLT
855
39
Station Speed Di-
al Number Entry
(SL1100)
0~9,
*
, # Maximum of
8 digit
Terminal: MLT, SLT
855
ISSUE 3.01
SL1000/SL1100
Programming Manual
2-77
Program
11
Содержание SL1100
Страница 1: ...Programming Manual A50 031167 002 EU ISSUE 3 01 Dec 2012 ...
Страница 32: ...Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 10 Program 10 System Configuration Setup Program 10 ...
Страница 57: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 35 Program 10 ...
Страница 77: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 55 Program 10 ...
Страница 96: ...Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 74 Program 11 System Numbering Program 11 ...
Страница 110: ...Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 88 Program 11 System Numbering Program 11 ...
Страница 138: ...Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 116 Program 14 Trunk Basic Setup Program 14 ...
Страница 178: ...Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 156 Program 15 Extension Basic Setup Program 15 ...
Страница 190: ...Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 168 Program 15 Extension Basic Setup Program 15 ...
Страница 197: ...Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 175 Program 20 ...
Страница 213: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 191 Program 20 ...
Страница 248: ...Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 226 Program 20 System Option Setup Program 20 ...
Страница 297: ...Feature Cross Reference Direct Inward Dialing DID ISSUE 3 01 SL1000 SL1100 Programming Manual 2 275 Program 22 ...
Страница 309: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 287 Program 22 ...
Страница 393: ...Feature Cross Reference Station Message Detail Recording ISSUE 3 01 SL1000 SL1100 Programming Manual 2 371 Program 35 ...
Страница 407: ...Feature Cross Reference Hotel Motel ISSUE 3 01 SL1000 SL1100 Programming Manual 2 385 Program 42 ...
Страница 413: ...Conditions None Feature Cross Reference Hotel Motel ISSUE 3 01 SL1000 SL1100 Programming Manual 2 391 Program 42 ...
Страница 453: ...Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 431 Program 47 ...
Страница 455: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 433 Program 47 ...
Страница 473: ...Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 451 Program 47 ...
Страница 475: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 453 Program 47 ...
Страница 477: ...Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 455 Program 47 ...
Страница 519: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 497 Program 82 ...
Страница 524: ...Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 502 Program 82 Basic Hardware Setup for Extension Program 82 ...
Страница 549: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 527 Program 84 ...
Страница 569: ...Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 547 Program 84 ...
Страница 586: ...Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 564 Program 90 Maintenance Program Program 90 ...
Страница 595: ...Feature Cross Reference Traffic Reports ISSUE 3 01 SL1000 SL1100 Programming Manual 2 573 Program 90 ...
Страница 623: ...Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 601 Program 90 ...
Страница 664: ...MEMO SL1000 SL1100 ISSUE 3 01 2 642 Program 93 System Information Program 93 ...
Страница 665: ...MEMO ISSUE 3 01 SL1000 SL1100 Programming Manual 2 643 ...
Страница 666: ...Programming Manual NEC Corporation ISSUE 3 01 ...