background image

Item

No.

Item

Input Data

Description

Default

Related

Program

11

Entry Credit for
Toll Restriction

0~9, 

*

, # Maximum of

4 digit (SL1000)
0~9, 

*

, # Maximum of

8 digit (SL1100)

Terminal: MLT

774

 

12

Night Mode
Switching for
Other Group

0~9, 

*

, # Maximum of

4 digit (SL1000)
0~9, 

*

, # Maximum of

8 digit (SL1100)

Terminal: MLT

718

12-xx

20-07-01

16

Leaving Message
Waiting (Re-
quires CPU to be
licensed for Ho-
tel/Motel)

0~9, 

*

, # Maximum of

4 digit (SL1000)
0~9, 

*

, # Maximum of

8 digit (SL1100)

Terminal: MLT

726

11-11-09

17

Dial Block by Su-
pervisor

0~9, 

*

, # Maximum of

4 digit (SL1000)
0~9, 

*

, # Maximum of

8 digit (SL1100)

Terminal: MLT

701

90-19

18

Off-Premise Call
Forward by Door
Box

0~9, 

*

, # Maximum of

4 digit (SL1000)
0~9, 

*

, # Maximum of

8 digit (SL1100)

Terminal: MLT

822

13-05

20

VRS - Record/
Erase Message

0~9, 

*

, # Maximum of

4 digit (SL1000)
0~9, 

*

, # Maximum of

8 digit (SL1100)

Terminal: MLT, SLT

Define Service Code for VRS mes-

sage recording or erasing.

716

20-07-13

21

VRS - General
Message Play-
back

0~9, 

*

, # Maximum of

4 digit (SL1000)
0~9, 

*

, # Maximum of

8 digit (SL1100)

Terminal: MLT, SLT

711

20-07-14

22

VRS - Record or
Erase General
Message

0~9, 

*

, # Maximum of

4 digit (SL1000)
0~9, 

*

, # Maximum of

8 digit (SL1100)

Terminal: MLT, SLT

712

20-07-15

23

SMDR - Exten-
sion Accumula-
ted Printout
Code

0~9, 

*

, # Maximum of

4 digit (SL1000)
0~9, 

*

, # Maximum of

8 digit (SL1100)

Terminal: MLT

721

20-07-18

24

SMDR - Group
Accumulated
Printout Code

0~9, 

*

, # Maximum of

4 digit (SL1000)
0~9, 

*

, # Maximum of

8 digit (SL1100)

Terminal: MLT

722

20-07-19

25

Account Code
Accumulated
Printout Code

0~9, 

*

, # Maximum of

4 digit (SL1000)
0~9, 

*

, # Maximum of

8 digit (SL1100)

Terminal: MLT

723

20-07-20

26

Forced Trunk
Disconnect

0~9, 

*

, # Maximum of

4 digit (SL1000)
0~9, 

*

, # Maximum of

8 digit (SL1100)

Terminal: MLT, SLT

724

20-07-11

27

Trunk Port Disa-
ble for Outgoing
Calls

0~9, 

*

, # Maximum of

4 digit (SL1000)
0~9, 

*

, # Maximum of

8 digit (SL1100)

Terminal: MLT, SLT

745

20-07-12

32

Set Private Call
Refuse

0~9, 

*

, # Maximum of

4 digit (SL1000)
0~9, 

*

, # Maximum of

8 digit (SL1100)

Terminal: MLT, SLT

746

14-01-27
20-07-24

33

Entry Caller ID
Refuse

0~9, 

*

, # Maximum of

4 digit (SL1000)
0~9, 

*

, # Maximum of

8 digit (SL1100)

Terminal: MLT

747

20-07-25

SL1000/SL1100

ISSUE 3.01

2-72

Program 11 : System Numbering

Program

11

Содержание SL1100

Страница 1: ...Programming Manual A50 031167 002 EU ISSUE 3 01 Dec 2012 ...

Страница 2: ...poration has prepared this document for use by its employees and customers The information contained herein is the property of NEC Corporation and shall not be reproduced without prior written approval of NEC Corporation Windows is a registered trademark of Microsoft Corporation Copyright 2011 2012 NEC Corporation Printed in Japan ...

Страница 3: ...U Network Setup 2 17 10 13 In DHCP Server Setup 2 20 10 14 Managed Network Setup 2 21 10 15 Client Information Setup 2 22 10 16 Option Information Setup 2 23 10 17 H 323 Gatekeeper Setup 2 26 10 18 H 323 Alias Address Setup 2 27 10 19 VoIPDB DSP Resource Selection 2 28 10 20 LAN Setup for External Equipment 2 29 10 23 SIP System Interconnection Setup 2 30 10 24 Daylight Savings Setup 2 31 10 25 H ...

Страница 4: ...Service Switching 2 95 12 04 Holiday Night Service Switching 2 96 12 05 Night Mode Group Assignment for Extensions 2 97 12 06 Night Mode Group Assignment for Trunks 2 98 12 07 Text Data for Night Mode 2 99 12 08 Night Mode Service Range 2 101 Program 13 Abbreviated Dialing 2 102 13 01 Speed Dialing Option Setup 2 102 13 02 Group Speed Dialing Bins 2 103 13 03 Speed Dialing Group Assignment for Ext...

Страница 5: ...2 176 20 03 System Options for Single Line Telephones 2 179 20 04 System Options for Virtual Extensions 2 181 20 05 System Options for Charging Cost Service 2 182 20 06 Class of Service for Extensions 2 183 20 07 Class of Service Options Administrator Level 2 184 20 08 Class of Service Options Outgoing Call Service 2 186 20 09 Class of Service Options Incoming Call Service 2 188 20 10 Class of Ser...

Страница 6: ... ISDN Calling Party Number Setup for Extensions 2 254 21 14 Walking Toll Restriction Password Setup 2 255 21 15 Individual Trunk Group Routing for Extensions 2 256 21 17 IP Trunk H 323 SIP Calling Party Number Setup for Trunk 2 257 21 18 IP Trunk H 323 Calling Party Number Setup for Extension 2 258 21 19 IP Trunk SIP Calling Party Number Setup for Extension 2 259 21 20 SIP Trunk Call Discernment S...

Страница 7: ...sers 2 311 25 10 Trunk Group Routing for DISA 2 312 25 11 DISA Toll Restriction Class 2 313 25 12 Alternate Trunk Group Routing for DISA 2 314 25 13 System Option for DISA 2 315 25 15 DISA Transfer Target Setup 2 316 Program 26 ARS Service Least Cost Routing 2 317 26 01 Automatic Route Selection ARS F Route Service 2 317 26 02 Dial Analysis Table for ARS LCR 2 319 26 03 ARS Dial Treatments 2 321 2...

Страница 8: ...Verified Account Code Table 2 378 Program 40 Voice Recording System 2 379 40 07 Voice Prompt Language Assignment for VRS 2 379 40 10 Voice Announcement Service Option 2 380 40 11 Preamble Message Assignment 2 382 Program 42 Hotel Setup 2 383 42 01 System Options for Hotel Motel 2 383 42 02 Hotel Motel Telephone Setup 2 384 42 03 Class of Service Options Hotel Motel 2 386 42 04 Hotel Mode One Digit...

Страница 9: ... 80 03 DTMF Tone Receiver Setup 2 463 80 04 Call Progress Tone Detector Setup 2 465 80 05 Date Format for SMDR and System 2 467 80 06 Reference Impedance Setup 2 468 80 07 Call Progress Tone Detector Frequency Setup 2 469 80 08 MFC Tone Setup 2 470 80 09 Short Ring Setup 2 471 80 11 MFC Tone Receiver Setup 2 473 80 12 Caller ID Receiver Setup 2 475 Program 81 Basic Hardware Setup for Trunk 2 476 8...

Страница 10: ...Firmware Name Setup 2 541 84 29 SIP MLT CODEC Information Fixed Mode Setup 2 542 84 31 VoIPDB Echo Canceller Setup 2 543 Program 90 Maintenance Program 2 548 90 01 Installation Date 2 548 90 02 Programming Password Setup 2 549 90 03 Save Data 2 551 90 04 Load Data 2 552 90 05 Slot Control 2 553 90 06 Trunk Control 2 554 90 07 Station Control 2 555 90 08 System Reset 2 556 90 09 Automatic System Re...

Страница 11: ...17 90 58 Restore Recovery Data 2 618 90 59 Delete Recovery Data 2 619 90 60 T1 ISDN Layer Status Information 2 620 90 63 DR700 Control 2 621 90 65 1st Party CTI Authentication Password Setup 2 622 90 66 FTP Firmware Update setup 2 623 90 67 Backup Data Auto save Interval Time Set 2 624 90 68 Side Tone Auto Setup 2 625 Program 92 Copy Program 2 626 92 01 Copy Program 2 626 92 02 Delete All Extensio...

Страница 12: ...rogram 22 03 Incoming Signal Frequency Patterns SL1000 2 268 Table 2 7 Program 22 03 Incoming Signal Frequency Patterns SL1100 2 268 Table 2 8 Function Number List 2 332 Table 2 9 Function Number List 2 336 Table 2 10 47 02 16 Default Table 2 422 Table 2 11 47 06 14 Default Table 2 427 Table 2 12 47 07 03 Default Table 2 429 Table 2 13 47 10 03 Default Table 2 435 Table 2 14 Basic Tones 2 457 Tabl...

Страница 13: ...s for each program are also included When you first install the system it uses the Default Setting for all programs Along with the Description are the Conditions which describe any limits or special considerations that may apply to the program The program access level is just above the Description heading You can only use the program if your access level meets or exceeds the level the program requ...

Страница 14: ...ension The second row of the display KY01 01 indicates that Key 01 is being programmed with the entry of 01 The third row allows you to move the cursor to the left or right depending on which arrow is pressed To learn how to enter the programming mode refer to How to Enter Programming Mode on page 1 2 SECTION 3 HOW TO ENTER PROGRAMMING MODE To enter programming mode 1 Go to any working display tel...

Страница 15: ...04 12 08 15 01 15 07 15 09 15 10 15 11 20 16 20 34 21 07 21 14 22 04 22 11 22 17 25 08 30 03 30 04 32 02 45 02 84 22 90 03 90 04 90 06 90 07 90 19 90 57 90 58 90 59 90 65 9999 admin2 4 SB System Administrator Level 2 SB 13 04 13 05 13 06 13 11 15 14 SL1100 21 20 SECTION 4 HOW TO EXIT PROGRAMMING MODE To exit the programming mode When you are done programming you must be out of a program option to ...

Страница 16: ...o enter data edit data and move around in the menus Table 1 1 Keys for Entering Data SL1000 When you want to Telephone Programming Enter Data into program 0 9 Line Key 1 6 Next Index Cursor Key Up Prior Index Cursor Key Down Select Data Line Key 1 6 All Clear Flash Register Hold Enter Go Back to Prior Screen Mute Clear Back Move Cursor Jump Up Down DND IP Phone Only or DND CONF Delete single chara...

Страница 17: ... Number Change Program Number Soft Key3 Change Index Number Move Cursor to Right Cursor Key Right Soft Key4 SECTION 6 PROGRAMMING NAMES AND TEXT MESSAGES Several programs e g Program 20 16 Selectable Display Messages require you to enter text Use the following chart when entering and editing text When using the keypad digits press the key once for the first character twice for the second character...

Страница 18: ...s for intuitive feature access The options for these keys will automatically change depending on where you are in the system programming Simply press the Softkey located below the option you wish and the display will change accordingly _ Program Mode Base Service OP1 OP2 Pressing the Cursor key Up or Down will scroll between the menus _ Program Mode Hard Mtnance SECTION 8 WHAT THE SOFTKEY DISPLAY ...

Страница 19: ...es Related Pro gram System Analog Caller ID Detector detec ted by DSP 132 channels SL1000 96 channels SL1100 Classes of Service 15 20 06 Day Night Mode Numbers 8 12 07 Day Night Service Patterns 4 12 07 Dial Tone Detector DTMF Receiver 132 SL1000 96 SL1100 Toll Restriction Classes 15 Verifiable Account Code Table 800 35 06 Trunk Trunk Port Number 126 SL1000 96 SL1100 Trunk Ports Total 126 SL1000 A...

Страница 20: ...1000 72 SL1100 Single Line Phones Analog Devices 128 SL1000 60 SL1100 VoIPDB Extensions SIP MLT Std VoIPDB MEMDB is re quired Need license to be Max SIP Std 32 Hybrid Extension Ports Physical Ports 01 08 SL1000 Digital Extension Ports Physical Ports 01 08 SL1100 Telephone Extension Number Range 1 8999 SL1000 1 89999999 SL1100 Extension cannot start with 0 or 9 Virtual Extension Ports 50 11 04 Virt...

Страница 21: ...L1000 120 SL1100 Paging and Park Internal Page Group Numbers 0 01 32 31 02 External Page Group Numbers 1 3 31 04 External Speakers 1 3 31 04 Park Group Numbers 1 64 24 03 Park Orbits 1 64 24 03 SMDR SMDR Ports 1 2 35 03 VRS VM InMail VRS VM InMail 1 VRS VM Ports Need license and MEMDB 16 VRS Port Need MEMDB 16 VRS Attendant Messages 3 VRS Recordable Messages 100 40 10 02 VRS Ports 16 VoIPDB RTP Po...

Страница 22: ...Some of slot number are fixed to a unit that be installed Other slots are not fixed to unit but fixed to location where it is installed Below chart shows the slot and its number Expansion KSU 1 3 Slot 0 Base Unit Main KSU Slot 1 Base Unit Slot 2 2nd Unit Slot 3 3rd Unit Slot 4 4th Unit C P U E X I F E Slot 5 9 13 Base Unit Slot 6 10 14 2nd Unit Slot 7 11 15 3rd Unit Slot 8 12 16 4th Unit SL1000 Ex...

Страница 23: ...ogram 24 Hold Transfer Setup on page 2 293 Program 25 VRS DISA Setup on page 2 301 Program 26 ARS Service Least Cost Routing on page 2 317 Program 30 DSS DLS Console Setup on page 2 330 Program 31 Paging Setup on page 2 342 Program 32 Door Box and Sensor Setup on page 2 353 Program 34 Tie Line Setup on page 2 357 Program 35 SMDR Account Code Setup on page 2 370 Program 40 Voice Recording System on...

Страница 24: ...or year 07 96 No Setting 02 Month 01 12 Enter 2 digits 01 12 for the month No Setting 03 Day 01 31 Enter 2 digits 01 31 for the day No Setting 04 Week 1 7 Sun Sat Enter digit for the day of the week 1 Sunday 7 Saturday No Setting 05 Hour 00 23 Enter 2 digits for the hour 00 23 No Setting 06 Minute 00 59 Enter 2 digits for the minute 00 59 No Setting 07 Second 00 59 Enter 2 digits for the second 00...

Страница 25: ... 02 International Access Code Dial up to four digits 0 9 Enter the international access code 00 03 Other Area Access Code Dial up to two digits 0 9 Enter the other area access code 0 04 Area Code Dial up to six digits 0 9 Enter the local area code No Setting 05 Trunk Access Code Dial up to eight dig its 0 9 Enter the trunk access code digits required to place an outgoing call No Setting Conditions...

Страница 26: ... Input Data Slot No 00 16 SL1000 00 09 SL1100 For HBI PKG Setup SL1000 Physical Port Number 01 08 Item No Item Input Data Default 01 Terminal Type 0 No setting 1 Multi Line Telephone 2 SLT 8 Door Phone 10 DSS Console 3 7 9 11 12 Not Used 2 02 Logical Port Number 1 128 03 Transmit Gain level for SLT 1 63 15 5 15 5dB 32 04 Receive Gain level for SLT 1 63 15 5 15 5dB 32 05 Select port type 0 Hybrid P...

Страница 27: ...01 08 Item No Item Input Data Default 01 Logical Port Number 0 120 0 03 Transmit Gain Level S Level 1 63 15 5 15 5 dB 32 0 dB 04 Receive Gain Level R Level 1 63 15 5 15 5 dB 32 0 dB 05 Select port type 0 SLT 1 Door Phone 0 For COIU Unit Setup Physical Port Number 1 4 Item No Item Input Data Default 01 Logical Port Number 1 48 SL1000 1 36 SL1100 0 02 Select port type SL1000 0 Trunk 1 Audio Port 0 F...

Страница 28: ... Sending ISDN Protocol definition 1 09 Dial Information Element 0 Keypad Facility 1 Called Party Number ISDN Protocol definition Only when Dialing Send ing Mode 10 03 08 is set for 1 Overlap Send ing 1 14 Service Protocol for S point 0 Keypad facility 1 Specified Protocol for Aspire sys tem 0 15 Call Busy Mode for S point 0 Alerting 1 Disconnect 0 17 ISDN Line Ringback Tone 0 Disable 1 Enable Syst...

Страница 29: ...ed 1 06 Length of Cable 0 Level 1 1 Level 2 2 Level 3 3 Level 4 4 Level 5 2 07 S point DDI digits 0 4 0 08 Dial Sending Mode 0 Enbloc Sending 1 Overlap Sending ISDN Protocol definition 1 09 Dial Information Element 0 Keypad Facility 1 Called Party Number ISDN Protocol definition Only when Dial Sending Mode 10 03 08 is set for 1 Overlap Sending 1 13 Loss Of Signal Detection Limit 0 Level 0 lowest s...

Страница 30: ...tandard same as NI 2 1 reserved 2 reserved 3 DMS A211 4 5ESS 5 DMS A233 6 4ESS 7 NI 2 Select the ISDN protocol for the ISDN circuit 0 21 Number of Ports 0 Auto 1 4 Ports 2 8 Ports 3 12 Ports 4 16 Ports 5 20 Ports 6 24 Ports 7 28 Ports 0 For PRI T1 PKG Setup Physical Port Number 01 24 Item No Item Input Data Description Default 01 Logical Port Number 1 126 SL1000 1 96 SL1100 The start port number o...

Страница 31: ...me Structure CRC 4 0 07 Line Coding 0 AMI 1 HDB3 1 10 Receive Input Threshold 0 0 91 1 70 V 1 0 74 0 84 V 2 0 59 0 84 V 3 0 42 0 45 V 4 0 32 0 45 V 5 0 21 0 20 V 6 0 16 0 10 V 7 0 10 not defined 2 For VoIPDB PKG Setup Physical Port Number 01 16 Item No Item Input Data Default 01 Trunk Logical Port Number 1 126 SL1000 1 96 SL1100 0 02 Trunk Type 0 H 323 1 SIP 1 Conditions When changing a defined te...

Страница 32: ...Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 10 Program 10 System Configuration Setup Program 10 ...

Страница 33: ...VMDB Tone set by PRG 10 04 02 Internal Music Tune The tune is set by Program 10 04 02 External Source ACI input via analog trunk port COI3 Program10 03 02 COIU SL1000 audio connector J421 Program10 60 01 SL1100 Silence Callers on hold hear silence 0 02 Music on Hold Tone Selection In case Item 1 is 0 1 Download File1 2 Download File2 3 Download File3 In case Item 1 is 1 2 or 3 1 100 VRS Message Nu...

Страница 34: ...6 SL1000 01 09 SL1100 ISDN Line No 01 04 Item No Item Input Data Default 01 TEI selection 0 Select by SPID number 1 Select by Channel ID number 0 02 DID mode 0 Route by Called Party Number 1 Route by Redirecting Number 0 03 SPID1 Maximum 20 digits No Setting 04 SPID2 Maximum 20 digits No Setting Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 12 Program 10 System Configurat...

Страница 35: ...ne conversation recording function can be used In this case 32 16 x 2 circuits will be shared by conference recording and conversation recording The number of the conference circuits occupied by a conversation recording is two Input Data Item No Item Input Data Default 01 The number of Conversation Re cording 0 16 0 No Setting 1 16 2 32 Conference Re source 0 Conditions None Feature Cross Referenc...

Страница 36: ... call then continues ringing with the normal ring cadence cycle Without pre ringing the call starts ringing only when the normal ring cadence cycle occurs This may cause a ring delay depending on when call detection occurs in reference to the ring cycle Input Data Item No Item Input Data Default 01 Pre Ringing 0 No 1 Yes 0 Conditions Used with Analog Trunks only Feature Cross Reference Central Off...

Страница 37: ... 20 SL1000 16 SL1100 circuits initially and an additional 16 circuits are added when a VMDB is installed By Adding EXIFE system can have up to 132 SL1000 96 SL1100 These are used as follows Extension DTMF receiver for single line telephone Trunk DTMF receiver for analog trunks dial tone busy tone detection for analog trunks Input Data Circuit Resource Number 01 132 SL1000 01 96 SL1100 ISSUE 3 01 S...

Страница 38: ...EXIFE1 resource only use Expansion 1 SL1100 Resource 65 96 are EXIFE2 resource only use Expansion 2 SL1100 Conditions CPU has 20 SL1000 16 SL1100 Channel DSP resources receivers only for basic CPU Unit VMDB has additional 16 DSP resources which you can add to CPU Addition to that EXIFE also each has 32 DSP resource receivers only for expand unit In case of 0 Common is selected and if 14 02 10 Call...

Страница 39: ...254 0 0 0 255 0 0 0 255 128 0 0 255 192 0 0 255 224 0 0 255 240 0 0 255 248 0 0 255 252 0 0 255 254 0 0 255 255 0 0 255 255 128 0 255 255 192 0 255 255 224 0 255 255 240 0 255 255 248 0 255 255 252 0 255 255 254 0 255 255 255 0 255 255 255 128 255 255 255 192 255 255 255 224 255 255 255 240 255 255 255 248 255 255 255 252 255 255 255 254 255 255 255 255 The setting of Subnet Mask is invalid when a...

Страница 40: ...ter IP Ad dress Default Gate way WAN 0 0 0 0 126 255 255 254 128 0 0 1 191 255 255 254 192 0 0 1 223 255 255 254 Set the IP address on the WAN side of router 0 0 0 0 08 ICMP Redirect 0 NO Signaling pack ets will follow the ICMP redirect message 1 YES Signaling pack ets will NOT follow the ICMP redirect message When receiving ICMP redirect message this determines if the IP Routing Table up dates au...

Страница 41: ... 248 0 255 255 252 0 255 255 254 0 255 255 255 0 255 255 255 128 255 255 255 192 255 255 255 224 255 255 255 240 255 255 255 248 255 255 255 252 255 255 255 254 255 255 255 255 Assign the subnet mask for the VoIPDB card 255 255 0 0 11 NIC Setup 0 Auto Detect 1 100 Mbps Full Du plex 3 10 Mbps Full Duplex 5 1 Gbps Full Duplex Set for VoIPDB 0 Conditions The system must be reset for these changes to ...

Страница 42: ...ilt in DHCP Server This program cannot be enabled if PRG10 63 01 is enabled 0 02 Lease Time Days 0 255 Lease Time of the IP address to a cli ent Pressing the Hold Key increments to the next setting data 0 day Hour 0 23 0 hour Minutes 0 59 30 minutes 05 Last DHCP Data 0 Disable 1 Enable If 10 13 01 is enabled this setting de termines if DHCP resource is enabled or disabled 1 Conditions None Feature...

Страница 43: ...on Default Related Pro gram 01 The Range of the IP address to Lease Minimum 0 0 0 0 126 255 255 254 128 0 0 1 191 255 255 254 192 0 0 1 223 255 255 254 When Maximum has not been entered the maximum value equals the minimum value 172 16 0 100 10 13 04 Maximum 0 0 0 0 126 255 255 254 128 0 0 1 191 255 255 254 192 0 0 1 223 255 255 254 172 16 5 254 Conditions None Feature Cross Reference None ISSUE 3...

Страница 44: ... Data Client Number 1 16 Item No Item Input Data Description Default 01 MAC Address MAC 00 00 00 00 00 00 FF FF FF FF FF FF 00 00 00 00 00 00 IP Address 1 0 0 0 126 255 255 254 128 0 0 1 191 255255 254 192 0 0 1 223 255 255 254 The IP address should be assigned out of the scope range set up in Program 10 14 0 0 0 0 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 22 Program ...

Страница 45: ... Code number 0 255 Set the name for the TFTP Server 66 Fixed Maximum 64 character strings No setting 05 MGC Code number 0 255 129 Fixed IP address 0 0 0 0 126 255 255 254 128 0 0 1 191 255 255 254 192 0 0 1 223 255 255 254 172 16 0 10 06 Client Host Name Code number 0 255 Set the Client Host Name 12 Fixed Maximum 64 character strings No setting 07 DNS Domain Name Code number 0 255 Set the DNS Doma...

Страница 46: ...er 0 255 120 Fixed IP address 0 0 0 0 126 255 255 254 128 0 0 1 191 255 255 254 192 0 0 1 223 255 255 254 172 16 0 10 17 SIP Server Domain Name Code number 0 255 If there is setting in 10 16 16 this setting will be ignored 120 Fixed Maximum 20 character strings No setting 18 FTP Server Code number 0 255 141 Fixed IP address 0 0 0 0 126 255 255 254 128 0 0 1 191 255 255 254 192 0 0 1 223 255 255 25...

Страница 47: ... 255 254 192 0 0 1 223 255 255 254 0 0 0 0 24 Next Server IP Address IP address 0 0 0 0 126 255 255 254 128 0 0 1 191 255 255 254 192 0 0 1 223 255 255 254 0 0 0 0 27 SIP Server Receive Port Code number 0 255 168 Fixed Port 1 65535 5080 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 25 Program 10 ...

Страница 48: ...y or manually if using an external Gatekeeper 0 02 Gatekeeper IP Ad dress 0 0 0 0 126 255 255 254 128 0 0 1 191 255 255 254 192 0 0 1 223 255 255 254 When Program 10 17 01 is set to 2 use this to set the IP Address of the Gatekeep er 0 0 0 0 04 Preferred Gatekeeper Maximum 124 charac ters When Program 10 17 01 is set to 1 use this to set the preferred ID of multiple Gatekeepers No Setting Conditio...

Страница 49: ...323 Gatekeeper Input Data Number of Alias 1 6 Item No Item Input Data Description Default 01 Alias Address Dial up to 12 digits 0 9 Set the telephone number Alias Address to external gatekeeper No Setting 02 Alias Address Type 0 E164 Set the Alias Address Type to external gatekeeper 0 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 27 Program 10 ...

Страница 50: ...n Default 01 VoIPDB DSP Re source Selection 0 Common use for both IP extensions and trunks 1 Use for IP exten sions 2 Use for SIP trunks 5 Blocked 6 Common without unicast paging 7 Multicast paging 8 Unicast paging This program is used to assign the 16 re sources of the VoIPDB NEC recommends leaving the default set tings as system default Resource 1 16 0 Conditions None Feature Cross Reference Non...

Страница 51: ...tput for Hotel Service 14 IP DECT Directory Access V3 0 Added Item No Item Input Data Default 01 TCP Port 0 65535 External Device 1 CTI Server 0 External Device 5 SMDR Output 0 External Device 6 DIM Output 0 External Device 9 1st Party CTI 0 External Device 11 O M Server 8080 External Device 12 Traffic Report Output 0 External Device 13 Room Data Output for Hotel Service 0 External Device 14 IP DE...

Страница 52: ...ress for SL1000 SL1100 system interconnection Input Data System Number 001 1000 Item No Item Input Data Default 01 System Interconnection 0 No Disable 1 Yes Enable 0 02 IP Address 0 0 0 0 126 255 255 254 128 0 0 1 191 255 255 254 192 0 0 1 223 255 255 254 0 0 0 0 03 Call Control Port Read Only 1 65535 1720 04 Dial Number Up to 12 digits 0 9 No Setting Conditions None Feature Cross Reference None S...

Страница 53: ...e time for daylight savings time 01 12 4 04 Start of Week 0 Last Week of Month 0 5 Enter the week of the month when the sys tem should adjust the time for daylight sav ings time The week will start on the day listed in 10 24 05 1 05 Start of Week Day 1 7 Sun 1 Mon 2 etc Enter the day of the week when the sys tem should adjust the time for daylight sav ings time 01 Sunday 02 Monday etc 1 06 End of ...

Страница 54: ... outside gatekeeper Input Data Item No Item Input Data Description Default Related Program 01 Gateway Prefix Entry 0 Off 1 On 0 02 Gateway Prefix Value Up to 12 digits 0 9 When Program 10 25 01 is set as 0 Off this setting will be ignored No Setting 10 25 01 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 32 Program 10 System Configuration Setup Program 10 ...

Страница 55: ...f 1 On 1 04 DR700 Peer to Peer Mode 0 Off 1 On 1 05 SIP CTI Mode 0 Disable 1 Mode1 When SIP CTI Mode is set as 1 Mode1 it will ignore the setting at 10 26 03 0 Conditions Disabling 10 26 04 results in SIP MLT Station to SIP MLT Station calls using a DSP resource SIP to SIP MLT Station does not support Peer to Peer function and will result in using a DSP resource Disabling 10 26 03 results in SIP I...

Страница 56: ...he span if there is no outbound CID info The rea son for this is the from and display portion of the invite message would be blank and it would not know where the call originated from No Setting 05 Domain Assignment 0 IP Address 1 Domain Name If the information from Telco was a domain name siptrunk sip com then set to do main If the information for Telco was a IP address then set to IP Address 0 0...

Страница 57: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 35 Program 10 ...

Страница 58: ...and used if the provider gives you a proxy address that is different than the registration address If the provid er is using domain names instead of IP ad dresses leave this at default 0 0 0 0 04 Default Proxy Port Number 0 65535 The port number of the Default Proxy is set 5060 05 Registrar Mode 0 None 1 Manual The mode registered in the registration server is set 0 06 Registrar IP Address 0 0 0 0...

Страница 59: ...5535 seconds This sets the expiration time when the SIP trunk registers to the Sip server When half the time set here passes the registration update is automatically done 3600 16 Register Sub Mode 0 Off Allow invalid In vite message 1 On Deny invalid In vite message Prevents an invalid Invite message If the register information that system send to SIP server and the Invite information that system ...

Страница 60: ...ault 02 User Name Up to 64 Characters This sets the user name of the SIP trunk No Setting 03 Password Up to 32 Characters This sets the SIP trunk password Web pro indicates password with mark V3 0 Added No Setting 04 Authentication Trial 0 9 This is how many times it will try an au thenticate before timing out and not regis tering 1 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE ...

Страница 61: ...location of the en tire end UA s 3600 02 Authentication Mode 0 Disable 1 Enable Check here if a password is desired for the IP SIP phones to register When checked 15 05 16 must have a password entered and also the SIP phone must have the same password When using Authentica tion the station number is the authoriza tion name 0 03 Registrar Proxy Do main Name Up to 64 Characters Set the domain name o...

Страница 62: ...s setting determines if the SIP trunk in formation is registered 0 02 User ID Up to 32 Characters This sets the SIP trunk User ID No Setting 03 Authentication User ID Up to 64 Characters This sets the SIP trunk Authentication User ID No Setting 04 Authentication Pass word Up to 32 Characters This sets the SIP trunk authentication password Web pro indicates password with mark V3 0 Added No Setting ...

Страница 63: ... Input Data Item No Item Input Data Description Default 01 UPnP Mode 0 Disable 1 Enable Router must support UPnP 0 02 Retry Time 0 60 3600 1 59 cannot be input Set interval time to re check the Router for the WAN IP address When this set as 0 it will not retry 60 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 41 Program 10 ...

Страница 64: ...Default 01 Fractional 0 Disable when disa bled the system will as sign the PRI as a full PRI trunks 1 Enable when ena bled the system will not assign any trunks to the PRI the trunks must be manually configured This program is used to enable disable the system s ability to use a fractional PRI or T1 0 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 42 Program 10 System Conf...

Страница 65: ...bility to use SIP trunks and assign the number of ports if IP Trunk is enabled Input Data Slot Number 0 Item No Item Input Data Default 01 IP Trunk Availability 0 Disable 1 Enable 0 02 Number of Ports 0 16 Port 0 0 Port 4 4 Port 8 8 Port 16 16 Port 0 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 43 Program 10 ...

Страница 66: ...Back Ports 0 30 0 No Setting 0 02 Logical Trunk Port Number Read Only 1 126 SL1000 1 96 SL1100 0 03 Logical Station Port Number Read Only 1 128 SL1000 1 120 SL1100 0 04 Layer 3 Timer Type 1 5 1 05 Calling Party Number 0 No 1 Yes 1 06 S point DDI digits 0 4 0 07 Call Busy Mode for S point 0 Alerting Message 1 Disconnect Message 0 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01...

Страница 67: ...248 0 0 0 252 0 0 0 254 0 0 0 255 0 0 0 255 128 0 0 255 192 0 0 255 224 0 0 255 240 0 0 255 248 0 0 255 252 0 0 255 254 0 0 255 255 0 0 255 255 128 0 255 255 192 0 255 255 224 0 255 255 240 0 255 255 248 0 255 255 252 0 255 255 254 0 255 255 255 0 255 255 255 128 255 255 255 192 255 255 255 224 255 255 255 240 255 255 255 248 255 255 255 252 255 255 255 254 255 255 255 255 0 0 0 0 03 Default Gatew...

Страница 68: ...ainst 84 22 15 05 27 If there is no match the phone does not come online 0 04 Server Name Up to 32 characters Assign the Server name to be used in the SIP URL sipphd 06 Register Port 0 65535 Assign the port number in which the SIP messages are sent to on the VoIPDB This same port number must be as signed in the SIP Multiline terminals If this command is changed it re quires a CPU reset 5080 07 Enc...

Страница 69: ...ubscribe Ses sion Port 0 65535 5081 14 NAT Mode 0 Off 1 On When the system controls the SIP multiline terminal via the NAT router this system data is set to On 0 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 47 Program 10 ...

Страница 70: ...he information of Terminal License Server Input Data Item No Item Input Data Description Default 01 Register Port of TCP I F 0 65535 This set the register port number of TCP I F 6080 02 TCP Keep Alive Time 1 255 seconds This set the TCP keep alive time 5 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 48 Program 10 System Configuration Setup Program 10 ...

Страница 71: ...ns The Key Operation for input item 03 is as follows SL1000 Hold Key Edit next feature code Up to 10 features code is possible to input at once Register the license when 10th feature code is edited Line Key1 Edit previous feature code Line Key2 Register the license SL1100 Hold Key Edit next feature code Up to 10 feature code is possible to input at once Register the license when 10th feature code ...

Страница 72: ... to enable the command to save the license file via CF Card which is issued from the license server Input Data Item No Item Input Data Default 01 Save License File on CF Card Dial 1 Hold Press Hold to cancel Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 50 Program 10 System Configuration Setup Program 10 ...

Страница 73: ...ored in a system Input Data Feature Code Number 000 9999 Item No Item Input Data Default 01 License Name Read Only Character 02 License Quantity Read Only 0 32767 03 Campaign License Quantity Read Only 0 32767 04 Campaign License Remaining Days Read Only 0 9999 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 51 Program 10 ...

Страница 74: ...er the unit works as PRI T1 or E1 Input Data Slot Number 01 16 V1 5 Changed SL1000 01 09 SL1100 Item No Item Input Data Description Default 01 PRI T1 E1 Selection 0 PRI 1 T1 2 E1 Chose whether the unit works as PRI T1 or E1 0 PRI Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 52 Program 10 System Configuration Setup Program 10 ...

Страница 75: ...rogram 10 52 Free Demo License Information to display information on free of charge Demo license Input Data Item No Item Input Data Default 01 Remaining days of Free Demo Li cense Read Only 0 9999 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 53 Program 10 ...

Страница 76: ... 0 1 191 255 255 254 192 0 0 1 223 255 255 254 Sets local network address 0 0 0 0 10 46 14 02 Subnet Mask 248 0 0 0 252 0 0 0 254 0 0 0 255 0 0 0 255 128 0 0 255 192 0 0 255 224 0 0 255 240 0 0 255 248 0 0 255 252 0 0 255 254 0 0 255 255 0 0 255 255 128 0 255 255 192 0 255 255 224 0 255 255 240 0 255 255 248 0 255 255 252 0 255 255 254 0 255 255 255 0 255 255 255 128 255 255 255 192 255 255 255 22...

Страница 77: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 55 Program 10 ...

Страница 78: ...ut Data Audio Port Number 1 BGM 2 External MOH Item No Item Input Data Description Default 01 Slot No 0 No Used 1 1st KSU 4 2nd KSU 7 3rd KSU Select which audio port on the 084M pack ages are used for BGM External MOH Audio Port Number 1 BGM Audio Port Number 2 External MOH 1 SL1100 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 56 Program 10 System Configuration Setup Pro...

Страница 79: ...0 1 6 SL1100 Item No Item Input Data Default 01 Relay Type 0 No Setting 1 External MOH 2 BGM resource 3 External Speaker 4 Door Phone 0 02 Destination Selection 10 61 01 1 or 2 Not Use 10 61 01 3 1 3 External Speaker Message No 10 61 01 4 1 8 Door Phone No SL1000 10 61 01 4 1 6 Door Phone No SL1100 0 Not Used Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual ...

Страница 80: ... Input Data Description Default 01 NetBIOS Mode 0 Disabled 1 Enabled 1 02 NetBIOS Name Maximum 15 characters Please avoid using Space between the words Also when you create name please use all upper letters SL1000 SL1000 SL1100 SL1100 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 58 Program 10 System Configuration Setup Program 10 ...

Страница 81: ...If you are using IP phones trunks it is rec ommended to not use the DHCP client function a static IP address would be pre ferred If you are going to still use the DHCP client function then the DHCP serv er should be setup so that the same IP ad dress is always provided to the system When changing this program a system reset is required 0 Conditions None Feature Cross Reference None ISSUE 3 01 SL10...

Страница 82: ...ing 6 affects all number plan entries beginning with 6 The entries you make in step 2 and step 3 below affect the entire range of numbers beginning with 6 For example if you enter 3 in step 2 the entries affected are 600 699 If you enter 4 in step 2 below the entries affected are 6000 6999 Entering two digits lets you define codes based on the first two digits a user dials For example entering 60 ...

Страница 83: ...4 xx 9 Dial Extension Ana lyze 11 20 Dial Extension Analyze Table on page 2 91 Changing the Dial Type for a range of codes can have a dramatic affect on how your system operates Assume for example the site is a hotel that has room numbers from 100 399 To make extension numbers correspond to room numbers you should use Program 11 02 to reassign extension numbers on each floor from 100 to 399 Other ...

Страница 84: ...gits Required Dial Type Default New Default New 21 0 0 22 0 0 23 0 0 24 0 0 25 0 0 26 0 0 27 0 0 28 0 0 29 0 0 20 0 0 2 0 0 2 0 0 3X 3 2 31 0 0 32 0 0 33 0 0 34 0 0 35 0 0 36 0 0 37 0 0 38 0 0 39 0 0 30 0 0 3 0 0 3 0 0 4X 3 2 41 0 0 42 0 0 43 0 0 44 0 0 45 0 0 46 0 0 47 0 0 48 0 0 49 0 0 40 0 0 4 0 0 4 0 0 SL1000 SL1100 ISSUE 3 01 2 62 Program 11 System Numbering Program 11 ...

Страница 85: ...igits Required Dial Type Default New Default New 5X 4 2 51 0 0 52 0 0 53 0 0 54 0 0 55 0 0 56 0 0 57 0 0 58 0 0 59 0 0 50 0 0 5 0 0 5 0 0 6X 3 2 61 0 0 62 0 0 63 0 0 64 0 0 65 0 0 66 0 0 67 0 0 68 0 0 69 0 0 60 0 0 6 0 0 6 0 0 7X 3 1 71 0 0 72 0 0 73 0 0 74 0 0 75 0 0 76 0 0 77 0 0 78 0 0 79 0 0 70 0 0 7 0 0 7 0 0 ISSUE 3 01 SL1000 SL1100 Programming Manual 2 63 Program 11 ...

Страница 86: ...gits Required Dial Type Default New Default New 8X 3 1 81 0 0 82 0 0 83 0 0 84 0 0 85 0 0 86 0 0 87 0 0 88 0 0 89 0 0 80 0 0 8 0 0 8 0 0 9X 1 5 91 0 0 92 0 0 93 0 0 94 0 0 95 0 0 96 0 0 97 0 0 98 0 0 99 0 0 90 0 0 9 0 0 9 0 0 0X 1 3 01 0 0 02 0 0 03 0 0 04 0 0 05 0 0 06 0 0 07 0 0 08 0 0 09 0 0 00 0 0 0 0 0 SL1000 SL1100 ISSUE 3 01 2 64 Program 11 System Numbering Program 11 ...

Страница 87: ... Used Dialed Number of Digits Required Dial Type Default New Default New 0 0 0 X 4 4 1 0 0 2 0 0 3 0 0 4 0 0 5 0 0 6 0 0 7 0 0 8 0 0 9 0 0 0 0 0 0 0 0 0 X 0 0 1 2 1 2 2 1 3 2 1 4 2 1 5 2 1 6 2 1 7 2 1 8 2 1 9 2 1 0 2 1 4 1 2 1 Conditions None Feature Cross Reference Flexible System Numbering ISSUE 3 01 SL1000 SL1100 Programming Manual 2 65 Program 11 ...

Страница 88: ... Input Data Extension Port Number 001 128 SL1000 001 120 SL1100 Item No Item Input Data Description Default 01 Extension Number Dial Up to 4 digits SL1000 Dial Up to 8 digits SL1100 Set up extension numbers for multiline tel ephones single line telephones and IP tel ephones Extension number assignments cannot be duplicated in Programs 11 02 and 11 07 Extension Port Number Exten sion Number 001 128...

Страница 89: ...ssigned in Program 11 01 or Program 11 20 Input Data Virtual Extension Numbers 001 050 Item No Item Input Data Description Default 01 Extension Number Dial Up to 4 digits SL1000 Dial Up to 8 digits SL1100 Set up Virtual Extension numbers The extension number cannot be dupli cated in Programs 11 02 and 11 07 Virtual Port Num ber Extension Number 1 50 No Set ting Conditions None Feature Cross Refere...

Страница 90: ...partment Extension Group Number 01 32 Item No Item Input Data Description Default Related Program 01 Extension Group Pilot Number Dial Up to 4 digits SL1000 Dial Up to 8 digits SL1100 Use this program to assign depart ment group pilot numbers The number set up by Program 11 02 Extension Numbering can not be used The extension number cannot be duplicated in Programs 11 02 and 11 07 No Setting 16 01...

Страница 91: ...s defined in Program 11 01 as Dial Type with the Number of Digits Required set to If you change the trunk access code in Program 11 09 you must make the corresponding changes in Program 11 01 Input Data Item No Item Input Data Description Default Related Program 01 Trunk Access Code Dial Up to four digits Use this program to assign the trunk access code This is the code exten sion users dial to ac...

Страница 92: ...es their call to the Alternate Trunk Route No Setting 11 01 System Num bering 14 01 07 Ba sic Trunk Data Setup 14 05 Trunk Group 14 06 Trunk Group Routing 21 02 Trunk Group Routing for Ex tensions 21 15 Individu al Trunk Group Routing for Ex tensions Conditions None Feature Cross Reference Automatic Route Selection ARS F Route Central Office Calls Placing Trunk Group Routing SL1000 SL1100 ISSUE 3 ...

Страница 93: ...t Terminal MLT 881 10 04 03 Setting the Sys tem Time 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT 828 04 Storing Common Speed Dialing Numbers 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT 853 05 Storing Group Speed Dialing Numbers 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT 854 06 Setting the Auto matic Transfer fo...

Страница 94: ...1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT 711 20 07 14 22 VRS Record or Erase General Message 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT 712 20 07 15 23 SMDR Exten sion Accumula ted Printout Code 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT 721 20 07 18 24 SMDR Group Accumulated Printout Code 0 9 Maximum of 4 digit SL1000 0 9 ...

Страница 95: ...minal MLT SLT Sets Service Code SC for Room monitor on off to terminal SC 1 Extension Number Room Monitor enable SC 0 Extension Number Room Monitor disable 710 46 Watch Message Setting 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT Service Code setting for Watching message recording to VRS 714 47 Warning Mes sage Setting 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 ...

Страница 96: ...Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 74 Program 11 System Numbering Program 11 ...

Страница 97: ...ximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT 848 02 Call Forward Busy 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT 1 03 Call Forward No Answer 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT 845 04 Call Forward Busy No Answer 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT 844 05 Cal...

Страница 98: ...0 02 12 17 Programmable Function Key Programming 3 Digit Service Co des 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT 851 15 07 11 11 38 18 BGM On Off 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT 825 19 Key Touch Tone On Off 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT 824 20 Change Incom ing CO and ICM Ring Tones 0...

Страница 99: ...L1100 Terminal MLT SLT 707 31 DND Cancella tion for Each Ex tension Group 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT 708 33 Dial Block 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT 700 34 Temporary Toll Restriction Over ride 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT 875 21 07 35 Pilot Group With dra...

Страница 100: ...50 Set Message Waiting Indica tion 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal SLT No Setting 51 Cancel Message Waiting Indica tion 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal SLT No Setting 52 Set Cancel Call Forward All Des tination No Split 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT 791 24 09 53 Set Cancel Call ...

Страница 101: ...of 8 digit SL1100 Terminal MLT SLT 764 47 02 16 69 IntraMail Lan guage Selection for specific ex tension 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT 765 20 13 53 47 02 16 70 Backlight Bright ness 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT 805 15 02 61 15 02 63 71 Auto Backlight 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL110...

Страница 102: ...0 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT Activating Call Forwarding Do Not Disturb Override This code is avail able only if you disable the voice mail Single Digit dialing code in Pro gram 11 16 09 807 02 Conference 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT 826 03 Override Off Hook Signaling 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Term...

Страница 103: ...git SL1100 Terminal MLT SLT 815 14 Trunk Group Ac cess 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT 804 15 Specified Trunk Access 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT 0 17 Clear Last Num ber Dialing Data 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT 876 18 Clear Saved Number Dialing Data 0 9 Maxi...

Страница 104: ... Pickup 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT 30 Specified Trunk Answer 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT 772 31 Park Hold 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT 6 24 03 32 Answer for Park Hold 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT 6 24 03 3...

Страница 105: ...er On Hook When Holding SLT 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal SLT 859 15 03 08 47 Call Waiting An swer Split An swer 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal SLT Splitting switching between calls 894 11 12 03 48 Account Code 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal SLT 51 VM Access 0 9 Maximum of 4 digit SL1...

Страница 106: ...T 887 62 Security Sensor Reset 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT Service Code setting for cancel Warning message sending and emergency call 816 63 Watch Mode Start 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT Service Code SC setting for on off watch mode SC 1 Watch mode start SC 0 Watch mode end 817 64 Security Sensor Mode ...

Страница 107: ...00 Terminal MLT SLT Determine what the service code should be for an internal party to set DND for an other extension 729 04 Cancel DND for Other Extension 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT Determine what the service code should be for an internal party to cancel DND for another extension 730 05 Set Wake Up Call for Own Extension 0 9 Maximum of 4 digit SL...

Страница 108: ...om Status Change for Own Extension 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT Determine what the service code should be for an internal party to change room status on their extension 740 15 Room Status Change for Other Extension 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT SLT Determine what the service code should be for an internal pa...

Страница 109: ...t Data Item No Item Input Data Description Default Related Program 01 Remote Mainte nance 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 830 05 System Program ming Mode Log On 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 Terminal MLT 11 01 09 Transfer to In coming Ring Group 0 9 Maximum of 4 digit SL1000 0 9 Maximum of 8 digit SL1100 No Setting 12 Extension Data Swap 0 ...

Страница 110: ...Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 88 Program 11 System Numbering Program 11 ...

Страница 111: ...e affected by changing these codes Input Data Item No Item Input Data Default Related Program 01 Step Call 0 9 Maximum of 1 digit 4 02 Barge In 0 9 Maximum of 1 digit No Setting 03 Switching of Voice Signal Call 0 9 Maximum of 1 digit 1 04 Intercom Off Hook Signaling 0 9 Maximum of 1 digit 05 Camp On 0 9 Maximum of 1 digit 06 DND Call Forward Override Bypass 0 9 Maximum of 1 digit No Setting 07 Me...

Страница 112: ...ies will call in order to connect to a conference Input Data Conference Group Number 1 4 Item No Item Input Data Default Related Program 01 Remote Conference Group Pilot Number Dial Up to 4 digits SL1000 Dial Up to 8 digits SL1100 See 20 13 46 20 34 No Remote Conference Pilot Numbers assigned to any Conference Group 1 4 Conditions None Feature Cross Reference Conference Remote SL1000 SL1100 ISSUE ...

Страница 113: ...Dial Extension Analyze Table Dial Up to four digits 0 1 9 SL1000 Dial Up to eight digits 0 1 9 SL1100 No Setting 11 01 02 Dial Extension Analyze Table Type of Dials 0 Not used 1 Service Code 2 Extension Number 5 Operator Access 6 F Route Access 0 11 01 Conditions When the system uses the Dial Extension Analyze Table to determine the dial type the lower table has priority For example if Table 1 has...

Страница 114: ...anges are not allowed 1 On Manual Night Mode changes are al lowed Allow Prevent a activating Night Service by dialing a service code 1 11 10 01 02 Automatic Night Mode Switching 0 Off Automatic Night Mode disabled 1 On Automatic Night Mode enabled According to a preset schedule en able or disable Automatic Night Service for the system 0 12 02 12 03 Even if the operation mode is changed manually th...

Страница 115: ... 2359 Refer below 03 Operation Mode 1 8 Night Modes 1 8 Refer below Example Time Pattern 1 0 00 9 00 12 00 13 00 17 00 18 00 22 00 0 00 M ode 3 m idnight M ode 3 m idnight M ode 2 night M ode 1 day M ode 1 day M ode 4 rest M ode 4 rest To make the above schedule it is necessary to set the data as follows Time setting 01 00 00 to 09 00 Mode 3 midnight Time setting 02 09 00 to 12 00 Mode 1 day Time ...

Страница 116: ...000 2 04 0000 0000 1 20 0000 0000 1 Time Pattern 2 Set Time Number Start Time End Time Mode 01 0000 0000 2 02 0000 0000 1 20 0000 0000 1 Time Pattern 3 10 Set Time Number Start Time End Time Mode 01 0000 0000 1 20 0000 0000 1 Conditions None Feature Cross Reference Night Service SL1000 SL1100 ISSUE 3 01 2 94 Program 12 Night Mode Setup Program 12 ...

Страница 117: ...ice Group Number 01 04 Item No Item Input Data Default 01 Day of the Week 01 Sunday 02 Monday 03 Tuesday 04 Wednesday 05 Thursday 06 Friday 07 Saturday Refer below Time Schedule Pattern Number 0 10 Default Day of the Week Time Schedule Pattern Number 01 Sunday 2 02 Monday 1 03 Tuesday 1 04 Wednesday 1 05 Thursday 1 06 Friday 1 07 Saturday 2 Conditions None Feature Cross Reference Night Service ISS...

Страница 118: ... used for the setting of special days when the company is expected to be closed such as a national holiday Input Data Night Mode Service Group Number 01 04 Item No Item Input Data Default 01 Days and Months 0101 1231 e g 0101 Jan 1 1231 Dec 31 No Setting Time Pattern Number 0 10 0 No Setting Conditions None Feature Cross Reference Night Service SL1000 SL1100 ISSUE 3 01 2 96 Program 12 Night Mode S...

Страница 119: ...ght Mode Group for each extension Input Data Extension Number Up to four digits SL1000 Up to eight digits SL1100 Item No Item Input Data Default 01 Night Mode Service Group Number 1 Night Mode Group 1 2 Night Mode Group 2 3 Night Mode Group 3 4 Night Mode Group 4 1 Conditions None Feature Cross Reference Night Service ISSUE 3 01 SL1000 SL1100 Programming Manual 2 97 Program 12 ...

Страница 120: ...ight Mode Group for each trunk port Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Item No Item Input Data Default 01 Night Mode Service Group Number 1 Night Mode Group 1 2 Night Mode Group 2 3 Night Mode Group 3 4 Night Mode Group 4 1 Conditions None Feature Cross Reference Night Service SL1000 SL1100 ISSUE 3 01 2 98 Program 12 Night Mode Setup Program 12 ...

Страница 121: ...ill be displayed on the phones display when the system en ters one of the eight different night modes Only phones that have manual night mode switching enabled in class of service PRG 20 07 01 will display the text Mode 1 No Setting SL1000 Mode 2 Night SL1000 Mode 3 M Night SL1000 Mode 4 Rest SL1000 Mode 5 Day2 SL1000 Mode 6 Night2 SL1000 Mode 7 M Night2 SL1000 Mode 8 Rest2 SL1000 Mode 1 No Settin...

Страница 122: ...Conditions None Feature Cross Reference Night Service SL1000 SL1100 ISSUE 3 01 2 100 Program 12 Night Mode Setup Program 12 ...

Страница 123: ...t Mode Key PRG 15 07 key 09 is assigned as a toggle key PRG 20 01 17 this data determines how many night modes a user toggles through when the Night Mode key is pressed Each press of the Night Mode key toggles to the next mode 2 Example When Program 12 08 is set to 3 and the Mode Key is pressed the following modes are switched Press once Night Press twice Mid night Press third Day Default 2 Condit...

Страница 124: ...n as though it is an Intercom number 1 0 13 05 02 Private Speed Di al 0 Do not use 1 Use Define use additional 20 Private speed dial bin beside 1000 Com mon speed dial bin or not 1 13 06 03 Number of Com mon Speed Dial ing Bins 0 1000 0 No Common Speed Dialing No System Speed Dial Assign the number of Speed Dial bins that are used for System Speed Dials 900 13 04 04 Trunk Access Routing V3 0 Added...

Страница 125: ...ssignment for Extensions on page 2 104 Input Data Speed Dialing Group Number 01 32 Item No Item Input Data Default 01 Start Address of Speed Dialing Bin 0 990 Refer below End Address of Speed Dialing Bin 0 9 999 Default Abbreviated dial group No Start address of ABB Bin End address of ABB Bin 1 0 0 32 0 0 Conditions None Feature Cross Reference Abbreviated Dialing Speed Dial ISSUE 3 01 SL1000 SL11...

Страница 126: ...sion There are 32 available Speed Dialing groups Input Data Extension Number Up to 4 digits SL1000 Up to 8 digits SL1100 Item No Item Input Data Description Default 01 Group Number 01 32 Assign group number for extension Assign each extension to a speed dialing group 1 Conditions None Feature Cross Reference Abbreviated Dialing Speed Dial SL1000 SL1100 ISSUE 3 01 2 104 Program 13 Abbreviated Diali...

Страница 127: ...n 000 999 as sign the telephone number that is to be called when the bin is accessed If 13 01 01 is set to 0 do not in clude the trunk access code If 13 01 01 is set to 1 include the trunk access code No Setting 02 Name Maximum 12 Charac ters Use dial pad to enter name No Setting 03 Transfer Mode 0 Not Used Calls will not be routed based off a users caller ID 1 Internal Dial Calls will be routed t...

Страница 128: ...3 0 Added SL1100 When set 1 or 2 at PRG13 04 03 this program is used to assign a ring pattern for the caller ID routed call 0 13 04 03 06 CR PR feature 0 Disable 1 Enable 0 14 05 07 VRS Message Number 0 100 If the VRS can not be played it will use a Program 13 04 05 Ringing Pattern V1 5 Added 0 08 Memo1 V1 5 De leted Maximum 28 digit Can only be changed in WebPro or PCPro No Setting 15 02 58 09 Me...

Страница 129: ...group routing of the caller s extension refer to Program 14 06 This setting is available only in External Speed Dialing Mode Program 13 01 01 Input Data Speed Dialing Bin Number 000 999 Item No Item Input Data Default 01 Trunk Group Route Number V3 0 Changed 0 Follow the caller s extension trunk group rout ing PRG 21 02 1 25 Trunk group 1 25 No Setting Conditions None Feature Cross Reference Abbre...

Страница 130: ... to 8 digits SL1100 Speed Dial Number 01 20 Item No Item Input Data Default 01 Speed Dialing Data 1 9 0 Pause Press line key 1 Recall Flash Press line key 2 Code to wait for answer supervision in ISDN Press line key 3 Maximum 36 digits No Setting Name Maximum 12 Characters Use dial pad to enter name Conditions None Feature Cross Reference Abbreviated Dialing Speed Dial SL1000 SL1100 ISSUE 3 01 2 1...

Страница 131: ...Abbreviated Dial Group Name to set the name of Abbreviated Dial Group Name Input Data Group Number 01 32 Item No Item Input Data Default 01 Group Name Up to 12 characters 1 ABB GROUP01 32 ABB GROUP32 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 109 Program 13 ...

Страница 132: ...ect the CODEC gain type used by the trunk when it is part of an Unsupervised Confer ence 32 0 dB 05 Receive Gain Level for Confer ence and Trans fer Calls 1 63 15 5 dB 15 5 dB in 0 5 dB intervals Use this option to select the CODEC gain type used by the trunk when it is part of an Unsupervised Confer ence 16 8 dB 06 SMDR Printout 0 No trunk will not be reported in the SMDR print out 1 Yes trunk wi...

Страница 133: ...ger than a pro grammed interval Program 24 01 05 If disabled forced dis connection does not occur Program 24 01 01 also affects this option 0 24 01 01 24 01 05 17 Trunk to Trunk Warning Tone for Long Conversa tion Alarm 0 Disable No 1 Enable Yes Use this option to enable or disable the Warning Tone for Long Conver sation feature for DISA callers 0 18 Warning Beep Tone Signaling 0 Disable No 1 Enab...

Страница 134: ...e Ringing by Caller ID 0 Disable No 1 Enable Yes 1 13 04 32 Anti trombone Function 0 No Effect No 1 Available Yes 0 33 APSU VM00 Trunk Receive Gain 1 63 15 5 dB 15 5 dB in 0 5 dB intervals Additional PAD when a trunk call connects to APSU Voice Mail 32 0 dB 38 Outgoing CLI se lection V3 0 Add ed 0 Contract Number 1 Extension Number 2 Extended Table 3 PRG21 13 4 PRG21 18 5 PRG21 19 6 No Digits Show...

Страница 135: ... information from the network is valid or not If the pro gram is set to 1 the caller name in formation the network provides is ig nored 0 Default Item01 Trunk Name Trunk Port Number Name 1 Line 001 2 Line 002 126 SL1000 96 SL1100 Line 126 SL1000 Line 96 SL1100 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 113 Program 14 ...

Страница 136: ...runks to ring and light cor rectly 0 03 Flash Type 0 Open Loop Flash 1 Ground This option selects the flash type open loop flash or ground Always set this option for open loop flash 0 04 Hooking Type 0 Timed Flash Hook ing 1 Disconnect Cut This option lets you use Flash for Timed Flash Program 81 01 14 or Disconnect Program 81 01 15 A user implements Flash by pressing the FLASH key while on a trun...

Страница 137: ...ity Reversing Polarity 1 Polarity Reversing or Timer Int Digit 1 21 01 03 09 Busy Tone De tection 0 Disable No 1 Enable Yes 0 10 Caller ID 0 Off Caller ID not displayed 1 On Caller ID is displayed Enable or disable a trunk ability to receive Caller ID information 0 11 Next Trunk in Rotary if No Dial Tone 0 Disable No 1 Enable Yes Use this option to enable disable the system ability to skip over a ...

Страница 138: ...Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 116 Program 14 Trunk Basic Setup Program 14 ...

Страница 139: ... is one item for each mode Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Day Night Mode 1 8 Item No Item Input Data Default Related Pro gram 01 Type of Connection 0 Stand Alone Trunk 1 Behind PBX PBX 3 CTX assume 9 0 22 02 Conditions None Feature Cross Reference Central Office Calls Placing ISSUE 3 01 SL1000 SL1100 Programming Manual 2 117 Program 14 ...

Страница 140: ...y seize the trunks in the order you specify in the outbound priority entry Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Item No Item Input Data 01 Trunk Group Number 0 25 Priority Number 001 126 SL1000 001 096 SL1100 Default Trunk Port Group Priority 1 1 1 126 SL1000 096 SL1100 1 126 SL1000 096 SL1100 Conditions None Feature Cross Reference Trunk Groups SL1000 SL1100 ISSUE 3 01 2 118...

Страница 141: ...than four trunk groups Route Number 1 Order 1 Trunk Group 1 Order 2 Trunk Group 2 For the above setting if all the lines in trunk group 1 are busy the system searches for an idle line in trunk group 2 With more than four trunk groups Route Number 1 Order 1 Trunk Group 1 Order 2 Trunk Group 2 Order 3 Trunk Group 3 Order 4 1002 Jump To Route Number 2 Route Number 2 Order 1 Trunk Group 4 Order 2 Trun...

Страница 142: ...cified 2 0 Not specified 3 0 Not specified 4 0 Not specified 1 0 Not specified 2 0 Not specified 3 0 Not specified 4 0 Not specified Route 25 1 0 Not specified 2 0 Not specified 3 0 Not specified 4 0 Not specified Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 120 Program 14 Trunk Basic Setup Program 14 ...

Страница 143: ...cess options for each Access Map Emergency calls will override Program 14 07 settings Input Data Access Map Number 001 126 SL1000 001 096 SL1100 Item No Item Input Data Description Default 01 Access Map 0 No access 1 Outgoing access only 2 Incoming access only 3 Access only when trunk on Hold 4 Outgoing access and access when trunk on Hold 5 Incoming access and access when trunk on Hold 6 Incoming...

Страница 144: ...096 SL1100 0 No access 126 SL1000 096 SL1100 1 0 No access 2 0 No access 126 SL1000 096 SL1100 0 No access Conditions None Feature Cross Reference Central Office Calls Answering Central Office Calls Placing SL1000 SL1100 ISSUE 3 01 2 122 Program 14 Trunk Basic Setup Program 14 ...

Страница 145: ...ata Trunk Port Number 001 126 SL1000 001 096 SL1100 Item No Item Input Data Description Default 01 MOH Type 0 Internal External MOH 1 BGM Source Select whether the system will use the built in Music on Hold External Music on Hold or a Customer provided source con nected to the BGM port 0 Conditions None Feature Cross Reference Music on Hold ISSUE 3 01 SL1000 SL1100 Programming Manual 2 123 Program...

Страница 146: ...Number 001 126 SL1000 001 096 SL1100 Item No Item Input Data Description Default 01 Recording Destina tion Extension Num ber Maximum four digits SL1000 Maximum eight digits SL1100 Enter the extension number where the trunk calls should be recorded No Setting 02 Automatic Recording for Incoming Calls 0 Off 1 On Determine if incoming trunk calls should be automatically recorded 0 04 Automatic Record...

Страница 147: ...H 323 Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Item No Item Input Data Default 01 IP Trunk ID 0 65535 0 No Setting 0 Conditions This Data is referred to at IP trunk outgoing call or IP trunk incoming call This ID is notified at IP trunk outgoing call It is not notified when ID is 0 Incoming Call arrives to the trunk port of the same ID as ID notified from the partner system Featu...

Страница 148: ... ID Setup for IP Trunk to define the SIP Register ID for IP Trunks Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Item No Item Input Data Default 01 Register ID 0 31 0 02 Pilot Register ID 0 31 0 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 126 Program 14 Trunk Basic Setup Program 14 ...

Страница 149: ...vation of Call Deflection Call Rerouting feature Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Item No Item Input Data Default Related Program 01 Operation Mode 0 Normal operation 1 Call Rerouting 2 Call Deflection 0 13 04 06 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 127 Program 14 ...

Страница 150: ...reference feature for more details 0 14 06 21 02 03 SMDR Printout 0 None Station will not be reported in the SMDR print out 1 Yes Station will be reported in the SMDR print out Use this option to include or exclude the extension in the SMDR report 1 04 ISDN Caller ID 0 Disabled CPN is NOT sent 1 Enabled CPN is sent If both Program 15 01 04 and 10 03 05 are enabled the system includes Caller ID in ...

Страница 151: ... 5 V3 0 Added SL1100 6 Tone pattern 6 V3 0 Added SL1100 7 Tone pattern 7 V3 0 Added SL1100 8 Tone pattern 8 V3 0 Added SL1100 When an incoming call is received from the extension defined in this PRG this item defines the ringtone presented 0 15 02 03 14 SMDR output of made intercom calls V2 0 Add ed 0 Disable 1 Enable When set 0 it will not record the in ternal calls that been made 0 15 01 49 15 S...

Страница 152: ...2 German 3 French 4 Italian 5 Spanish 6 Dutch 7 Portuguese 8 Norwegian 9 Danish 10 Swedish 11 Turkish 12 Latin American Spanish 13 Romanian 14 Polish 16 Russian V2 0 Added 99 Flexible Language V3 0 Added This program sets the Display Lan guage for the extension port you are programming To select options 6 11 dial 6 or prss Help until 2 shows in the far right of screen then press line keys 1 6 To s...

Страница 153: ...elody 2 DR700 SL1000 6 Tone Pattern 6 DR300 Melody 3 DR700 SL1000 7 Tone Pattern 7 DR300 Melody 4 DR700 SL1000 8 Tone Pattern 2 DR300 Melody 5 DR700 SL1000 1 High SL1100 2 Medium SL1100 3 Low SL1100 4 Ring Tone 1 SL1100 5 Ring Tone 2 SL1100 6 Ring Tone 3 SL1100 7 Ring Tone 4 SL1100 8 Ring Tone 5 SL1100 Use this option to set the tone pitch of the incoming trunk ring for the extension port you are ...

Страница 154: ...ith Speed Dialing The Redial key can access either the Common Individual or Group Speed Dialing numbers 0 05 Transfer Key Op eration Mode 0 Transfer 1 Call back 2 Hook Use this option to set the operating mode of the extension Transfer key The keys can be for Call Transfer Serial Calling or Flash When select ing the Flash option selection 2 refer also to Program 81 01 14 0 06 Hold Key Operat ing M...

Страница 155: ... call 0 Disable Off 1 Enable On 1 16 Handsfree Oper ation 0 Disable Off 1 Enable On Enable or disable an extension abili ty to use the speakerphone on out side calls When disabled users can hear the conversation but cannot respond handsfree 1 18 Power Saving Mode 0 Normal mode 1 Power Saving Mode Eco Mode 1 21 Virtual Extension Access Mode when idle Virtual Extension key pressed 0 DSS 1 Outgoing O...

Страница 156: ...on Trunk Mode The Caller ID Scroll stores Trunk calls only 0 or both Internal and Trunk calls 1 1 35 Message Waiting Lamp Cycle for Calling Exten sion 1 Cycle 1 2 Cycle 2 3 Cycle 3 4 Cycle 4 5 Cycle 5 6 Cycle 6 7 Cycle 7 Select the cycle method that the Large LED flashes when the exten sion has set Message Waiting 7 36 Message Waiting Lamp Cycle for Called Extension 1 Cycle 1 2 Cycle 2 3 Cycle 3 4...

Страница 157: ... 0 55 VRS Message Number 0 100 0 56 Screen Saver Timer SL1000 0 200 0 2000 sec onds 0 57 Caller Log on busy 0 Off 1 On 0 15 02 34 58 Display mode of trunk incoming V1 5 Deleted 0 Caller ID 1 Memo Information 0 13 04 08 13 04 09 13 04 10 60 Soft Key Naviga tion key Mode 0 Standard Mode 1 Advanced Mode1 2 Advanced Mode2 1 61 Backlight Max Brightness 0 8 6 62 Backlight Min Brightness 0 8 0 63 Auto Ba...

Страница 158: ...requency 2 Modulation External Incoming Signal Frequency Pattern 1 High Middle Low 1100 Hz 660 Hz 520 Hz 1400 Hz 760 Hz 660 Hz 16 Hz 16 Hz 16 Hz External Incoming Signal Frequency Pattern 2 High Middle Low 1100 Hz 660 Hz 520 Hz 1400 Hz 760 Hz 660 Hz 8 Hz 8 Hz 8 Hz External Incoming Signal Frequency Pattern 3 High Middle Low 2000 Hz 1400 Hz 1100 Hz 760 Hz 660 Hz 540 Hz 16 Hz 16 Hz 16 Hz External In...

Страница 159: ...red When upgrading software from prior ver sions the previous default of 1 is saved from the prior database so this option must be changed man ually 1 15 03 03 45 01 01 03 Terminal Type 0 Normal 1 Special Enter 1 for this option to allow a sin gle line port to receive DTMF tones after the initial call setup Enter 0 to have the port ignore DTMF tones af ter the initial call setup For Voice Mail alw...

Страница 160: ...ultiline terminal receives a forwarded outside call 0 15 Disconnect with out dial after hooking hold 0 Normal 1 Disconnect Determine whether or not to discon nect a held call when on hook with out any dialing after hooking hold 0 16 Special DTMF Protocol Send 0 No 1 Yes Determine whether or not to send the extension number of the phone forwarded to the extension when Program 15 03 04 is set to Spe...

Страница 161: ...Conditions None Feature Cross Reference Single Line Telephones ISSUE 3 01 SL1000 SL1100 Programming Manual 2 139 Program 15 ...

Страница 162: ...th the extension in which the MAC address matches 00 00 00 00 00 00 15 05 01 04 Nickname Up to 48 characters Nickname section on Invite mes sage Example Extension 100 has a Nickname set to PAUL Extension 101 has command 15 05 17 set to Nickname The inbound call to extension 101 from 100 shows PAUL Nickname must be unique in the system No Setting 15 05 17 07 Using IP Address Read Only 0 0 0 0 255 2...

Страница 163: ... using manual auto registration as sign each phone a unique personal index Then go to command 84 22 to assign the user name and pass word 0 84 22 28 Addition Infor mation Setup 0 Do not inform 1 Inform Select whether to inform of addition al information or not 0 15 01 01 15 02 13 15 02 15 15 02 34 29 Terminal WAN side IP Address Read Only 0 0 0 0 255 255 255 255 0 0 0 0 30 DTMF Play dur ing Conver...

Страница 164: ... 12 hour 12 42 Time Zone mi nute 0 120 60 60 minute 60 43 Video Mode 0 Disable 1 Enable 0 45 NAT plug play 0 OFF 1 ON Effective only when PRG 10 46 14 is set to NAT mode Select sending RTP port number to remote Router use from negotiation result 0 or received RTP packet 1 1 10 46 14 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 142 Program 15 Extension Basic Setup Program...

Страница 165: ...h it has outgoing access Use Program 14 07 to define the available access maps Input Data Extension Number Maximum four digits SL1000 Maximum eight digits SL1100 Day Night Mode 1 8 Item No Item Input Data Default Related Program 01 Trunk Access Map Number 001 126 SL1000 001 096 SL1100 1 14 07 Conditions None Feature Cross Reference Central Office Calls Answering Central Office Calls Placing ISSUE ...

Страница 166: ...igits SL1000 Maximum eight digits SL1100 Default Settings Line Key Function Number Additional Data LK01 01 Trunk Line Key 1 LK12 01 Trunk Line Key 12 LK13 0 No setting 0 LK24 0 No setting 0 Item No Item Input Data Additional Data 01 Line Key Number 1 24 Refer to Table 2 2 Function Number List on page 2 145 Function Number 0 99 0 99 Normal Function Code Service Code 851 by default 00 99 Appearance ...

Страница 167: ...o CID 09 Day Night Mode Switch Mode number 1 8 0 toggle On While each mode 10 Call Forward Immediate Slow Blink Red Setup SL1000 On Red Setup SL1100 11 Call Forward Busy Slow Blink Red Setup SL1000 On Red Setup SL1100 12 Call Forward No Answer Slow Blink Red Setup SL1000 On Red Setup SL1100 13 Call Forward Busy No Answer Slow Blink Red Setup 14 Call Forward Both Ring Slow Blink Red Setup SL1000 On...

Страница 168: ...ast Blink Red To be monitored 41 Buzzer Extension Number On Red Calling party Fast Blink Red Called party 42 Boss Secretary Call Extension Number On Red Active 43 Series Call None 44 Common Hold None 45 Exclusive Hold None 46 Department Group Log Out On Red Withdrawing 47 Reverse Voice Over Softphone doesn t sup port Re verse Voice Over V1 5 Added Extension Number Same as DSS SL1100 48 Voice Over ...

Страница 169: ... Hold Key 74 Keypad RE TRIEVE Key 75 Keypad Confer ence Key 76 Application Key Any dial data 8 dig it None 77 Voice Mail In Skin Extension Number or Pilot Number InMail Fast Blink Green New Message s in own Mail box Slow Blink Red New Message s in other Mail box External VM On Red Access to Voice Mail Fast Blink Green New Message s in own Mail box Slow Blink Red New Message s in other Mail box 78 ...

Страница 170: ... 125msec off 125msec on 625msec off Red Pattern 4 SL1100 94 Call Attendant Fast Blink Red Setup No answer calls Slow Blink Red Setup Busy calls SL1000 125 ms On 125 ms Off 125 ms On 625 ms Off Red Setup Busy calls SL1100 On Red Setup Busy No answer calls 97 Door Box Access Key Door Box Number 1 8 SL1000 Door Box Number 1 6 SL1100 On Red Doorphone Busy Off Doorphone Idle Fast Blink Red Doorphone In...

Страница 171: ...625msec off Green Speaking own SL1000 On Red Speaking other Transferring other SL1000 Slow Blink Green Holding own SL1000 Slow Blink Red Holding other Recall other SL1000 Fast Blink Red Incoming own other Recall own SL1100 On Green Speaking own SL1100 On Red Speaking other SL1100 Slow Blink Green Holding own Transferring own SL1100 Slow Blink Red Holding other Transferring other Recall other SL110...

Страница 172: ...0 pattern 3 1 1 1 1 0 1 1 1 1 0 011 pattern 4 1 0 1 0 1 0 0 0 0 0 100 pattern 5 1 0 0 0 0 0 0 0 0 0 101 pattern 6 1 0 1 0 0 0 0 0 0 0 110 pattern 7 1 1 1 1 1 1 0 1 0 1 111 200 400 600 800 1000 1200 1400 1600 1800 2000 m s SL1000 SL1000 SL1100 ISSUE 3 01 2 150 Program 15 Extension Basic Setup Program 15 ...

Страница 173: ...ink General Function Level LED pattern 1 SL1000 LED pattern 5 SL1100 Slow Blink Appearance Function Level LED pattern 1 Fast Blink LED pattern 0 SL1000 LED pattern 3 SL1100 Stutter Blink LED pattern 4 SL1100 1200msec on 200msec off 200msec on 200msec off 200msec on LED pattern 7 SL1000 Conditions When a key is programmed using service code 852 it cannot be programmed with a function using the 851 ...

Страница 174: ...one Pattern 3 3 Tone Pattern 4 4 Incoming Ring Tone Extension 5 Tone pattern 5 SL1000 6 Tone pattern 6 SL1000 7 Tone pattern 7 SL1000 5 Tone pattern 5 V3 0 Added SL1100 6 Tone pattern 6 V3 0 Added SL1100 7 Tone pattern 7 V3 0 Added SL1100 8 Tone pattern 8 V3 0 Added SL1100 When an extension or a virtual extension is assigned to the function key on the key telephone select the ring tone when re cei...

Страница 175: ...h Middle Low 2000 Hz 1400 Hz 1100 Hz 760 Hz 660 Hz 540 Hz 8 Hz 8 Hz 8 Hz Internal Incoming Sig nal Frequency High Middle Low 1100 Hz 660 Hz 520 Hz 1400 Hz 760 Hz 660 Hz 8 Hz 8 Hz 8 Hz Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 153 Program 15 ...

Страница 176: ...s and names to virtual extension ports in Program 15 01 Program Virtual Extension keys in Program 15 07 code 03 There are 50 Virtual Extension Ports Input Data Extension Number Maximum four digits SL1000 Maximum eight digits SL1100 Key Number 01 24 Day Night Mode 1 8 Item No Item Input Data Default 01 Ringing 0 No Ringing 1 Ring 0 Conditions Program the Multiple Directory Number function keys NOT ...

Страница 177: ...der 1 4 When two or more virtual extensions are set on a function key on the tele phone and the tone pat tern by which the sound of each extension differs the priority of ring sound is set up 15 08 Data 0 Tone Pattern 1 1 Tone Pattern 2 2 Tone Pattern 3 3 Tone Pattern 4 4 Incoming Extension Ring Tone 5 Tone pattern 5 SL1000 6 Tone pattern 6 SL1000 7 Tone pattern 7 SL1000 5 Tone Pattern 5 V3 0 Adde...

Страница 178: ...Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 156 Program 15 Extension Basic Setup Program 15 ...

Страница 179: ...m 15 01 to virtual extension ports Program Multiple Directory Number virtual extension keys in Program 15 07 code 03 Input Data Extension Number Maximum four digits SL1000 Maximum eight digits SL1100 Key Number 01 24 Day Night Mode 1 8 Item No Item Input Data Default Related Program 01 Ringing 0 Immediate Ring 1 Delayed Ring 0 20 04 03 15 09 01 Conditions Program the Virtual Extension keys NOT to ...

Страница 180: ...gits SL1100 Item No Item Input Data Description Default 01 Recording Destina tion Extension Num ber Maximum four digits SL1000 Maximum eight digits SL1100 Enter the extension number to which the trunk calls should be recorded No Setting 02 Automatic Recording for Incoming Calls 0 Off 1 On Determine if an extension incoming calls should be automatically recorded 0 04 Automatic Recording for Outgoin...

Страница 181: ...ximum four digits SL1000 Maximum eight digits SL1100 Key Number 01 24 Item No Item Input Data Default 01 Outgoing Option 0 25 0 Assigns the Loop Key for ARS 1 25 As signs the Loop Key to the trunk group specified 0 Programming Func tion Key No 01 24 02 Incoming Option 0 25 0 Assigns the Loop Key to all trunk groups 1 25 Assigns the Loop key to the trunk group specified 0 Programming Func tion Key ...

Страница 182: ...ls is also changed Input Data Extension Number Maximum eight digits Key Number 01 10 Item No Item Input Data Description Default 01 Dial Data Maximum of 36 digits 0 9 P R Wait for Answer Su pervision ISDN trunks only P Pause Analog Trunk Only R Hook flash Analog Trunk Only If PRG 15 02 60 is set to a 0 then the stations personal speed dial entries are programmed here Per key number 1 10 assign the...

Страница 183: ...r ID Setup for Extension to define the SIP Register ID for Extensions Input Data Extension Number Maximum four digits SL1000 Maximum eight digits SL1100 Item No Item Input Data Default 01 Register ID None 0 31 No Setting Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 161 Program 15 ...

Страница 184: ...ssignment on each CO line Input Data Extension Number including Virtual Extensions Up to four digits SL1000 Up to eight digits SL1100 Trunk Port Number 001 126 SL1000 001 096 SL1100 Item No Item Input Data Default 01 LED Flash Assignment 0 LED Off 1 LED On 0 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 162 Program 15 Extension Basic Setup Program 15 ...

Страница 185: ...hen set to a 0 the caller ID of a trunk call station call pointed to a vir tual extension will not be displayed if the virtual extension is not set to ring When set to a 1 the caller ID of a trunk call pointed to a virtual ex tension will be displayed if the virtual extension is not set to ring Station calls to a virtual that is not assigned to ring will display the station name or number if PRG 1...

Страница 186: ...ndition If a DIL rings a Virtual Extension the Virtual Extension Key Operation Mode must be set to 1 Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 164 Program 15 Extension Basic Setup Program 15 ...

Страница 187: ...dial when answered for the call to cut through on ALL line types 1 On Analog Line User must dial when answered for the call to cut through on Analog lines only 2 Never When the call is answered the call is immediately cuts through Per Mobile Extension assigned in PRG 11 02 select whether a confirmation is re quired user dials to allow the call to cut through when answered 0 03 Trunk Access Code 0 ...

Страница 188: ...nal that is used as the SIP extension When Program 15 24 03 is set to 1 this Program cannot be changed from 0 0 0 0 except using PCProgramming 0 0 0 0 02 Call Procedure Port 0 65535 Call procedure port of the standard SIP terminal that is used as SIP extension 5060 03 Registration Setting when REGISTER isn t used 0 Disable 1 Enable Enables or disables the Registration meth od An error will occur i...

Страница 189: ...ing tone SL1000 1 Tone pattern1 SL1000 2 Incoming external ring tone SL1000 3 Tone pattern 3 SL1000 4 Tone pattern 4 SL1000 5 Tone pattern 5 SL1000 6 Tone pattern 6 SL1000 7 Tone pattern 7 SL1000 8 Tone pattern 2 SL1000 0 Trunk incoming ring tone SL1100 1 High SL1100 2 Middle SL1100 3 Low SL1100 4 Melody 1 SL1100 5 Melody 2 SL1100 6 Melody 3 SL1100 7 Melody 4 SL1100 8 Melody 5 SL1100 Assign indivi...

Страница 190: ...Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 168 Program 15 Extension Basic Setup Program 15 ...

Страница 191: ... department number This only occurs for calls to the ex tension directly not the department number assigned in Program 11 07 0 16 02 04 Hunting Mode 0 Last extension is called and hunting is stopped 1 Circular Use this option to set the action tak en when a call reaches the last ex tension in the Department Group 0 hunting stopped 1 hunting re peats with circular routing through the Department Gro...

Страница 192: ...09 Department Hunting No An swer Time 0 64800 seconds Set how long a call rings a Depart ment group extension before hunt ing occurs 15 10 Enhanced Hunt Type 0 No hunting 1 Hunting When Busy 2 Hunting When Not Answered 3 Hunting When Busy or No Answer Set the type of hunting for each Ex tension Department Group 0 Conditions None Feature Cross Reference Department Calling SL1000 SL1100 ISSUE 3 01 2...

Страница 193: ...group the extensions ring in order of their priority Input Data Extension Number Maximum four digits SL1000 Maximum eight digits SL1100 Item No Item Input Data Default Description Related Program 01 Group Num ber 1 32 1 xxx See Set up the Department Group called by the pilot number and the exten sion priority when a group is called Call Pickup Groups are set up in 23 02 11 07 16 01 Priority 1 999 ...

Страница 194: ...artment Groups Input Data Department Extension Group Number 01 32 Item No Item Input Data Description 01 Secondary Extension Num ber 1 16 This program is set up when placing tele phones in two or more groups Extension Number Maximum 4 digits SL1000 Maximum 8 digits SL1100 Priority Order 0 999 Default All extension groups No setting Conditions None Feature Cross Reference Department Calling SL1000 ...

Страница 195: ...ach department group can restrict calls to up to 8 department groups in Department Group Departmental Call Restriction Input Data Extension Department Group Number 1 32 Restricted Group Index 1 8 Item No Item Input Data Description Default 01 Restrict Department Group Number 0 32 Calls between members of different De partment Station groups can be restricted on a per group basis 0 Conditions None ...

Страница 196: ... Trunk Queuing Callback Time 0 64800 seconds Trunk Queuing callback rings an ex tension for this time 15 11 12 05 15 07 35 09 Callback Trunk Queuing Cancel Time 0 64800 seconds The system cancels an extension Callback or Trunk Queuing request after this time 64800 11 12 05 15 07 35 10 Trunk Guard Timer 0 64800 seconds The amount of time the system waits to seize the next outside line after the sys...

Страница 197: ...Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 175 Program 20 ...

Страница 198: ...cess Key Operating Mode 0 Outgoing Incoming 1 Outgoing 2 Incoming Use this option to set the oper ating mode of the extension trunk group keys The keys are for incom ing access outgoing ac cess or both 0 03 BLF Control SL1100 0 Idle Busy ON OFF 1 Busy Idle ON OFF Set the condi tions under which a Hot line Reverse Voice Over or DSS Console key indicates that an exten sion is busy Refer to the Rever...

Страница 199: ...hour 10 MAR TUE 3 15 SL1000 Type 10 24 hour 10 MAR TUE 15 15 SL1000 1 8 SL1100 Type 1 12 hour 10 MAR TUE 3 15 PM SL1100 Type 2 12 hour 3 15 PM MAR 10 TUE SL1100 Type 3 12 hour 3 10 TUE 3 15 PM SL1100 Type 4 12 hour 3 15 PM TUE 10 MAR SL1100 Type 5 24 hour 10 MAR TUE 15 15 SL1100 Type 6 24 hour 15 15 MAR 10 TUE SL1100 Type 7 24 hour 3 10 TUE 15 15 SL1100 Type 8 24 hour 15 15 TUE 10 MAR SL1100 Set h...

Страница 200: ...ced Intercom Ring ICM Call Type 0 Disable Voice 1 Enable Signal Use this option to enable or disable Forced Intercom Ring ing If enabled incoming Inter com calls nor mally ring If disabled Inter com calls voice an nounce 1 15 Caller ID Display Mode 0 Name and Number Both 1 Name 2 Number 0 18 Dialing Record Dis play Time 0 64800 seconds 30 19 DSS Key Virtual Extension Mode 0 No 1 Yes Sets the mode ...

Страница 201: ...le line tel ephone on a trunk in a buffer Af ter all the digits are received the system sends all the digits to the trunk If the time space between digits is longer than the time in Item 4 the system considers all digits received Type 1 The system passes the received digits from the single line telephone to the trunk immediate ly If the single line telephone has a Last Number Dial key without a pa...

Страница 202: ... expires from the time when a single line telephone is off hook the system sets the single line telephone to headset ringing mode 5 20 13 38 07 Trunk Call Dial Forced Sending Start Time Forced Dial 0 64800 seconds 0 20 03 03 20 03 04 Conditions None Feature Cross Reference Single Line Telephones SL1000 SL1100 ISSUE 3 01 2 180 Program 20 System Option Setup Program 20 ...

Страница 203: ... loop key With an entry of 1 after answering a call on a virtual extension key once the call is picked up the call will remain on the virtual extension key 0 15 18 01 03 Virtual Extension Delay Interval 0 64800 seconds Virtual Extensions set for Delayed Ringing see Program 15 11 ring the extension after this time 10 04 Virtual Extension Key Seize Mode 0 Normal 1 Enhanced Option When set to Enhance...

Страница 204: ...o decimal point 1 Decimal point s character is period 2 Decimal point s character is comma 1 07 Advice of Charge for SMDR 0 No decimal point 1 Decimal point s character is period 2 Decimal point s character is comma 1 08 Value per Charge for SMDR V3 0 Added 1 65535 1 09 Multiplier for Charging Unit Price V3 0 Added 0 one thousandth 1 1000 1 one hundredth 1 100 2 one tenth 1 10 3 one 1 4 ten 10 5 h...

Страница 205: ...n each Class of Service refer to Programs 20 07 through 20 13 You make eight entries for Program 20 06 one for each Night Service Mode Input Data Extension Number Maximum four digits SL1000 Maximum eight digits SL1100 Day Night Mode 1 8 Item No Item Input Data Default 01 Class of Service for Extensions 1 15 All extension numbers are set as Class 1 Conditions None Feature Cross Reference Class of S...

Страница 206: ...em or Group Speed Dialing numbers COS 1 15 1 11 10 04 05 Set Cancel Auto matic Trunk to Trunk Transfer 0 Off 1 On Turns off or on an extension user ability to use the Trunk to Trunk Forwarding service codes COS 1 15 1 11 10 06 11 10 07 11 10 08 06 Charging Cost Display 0 Off 1 On COS1 14 COS15 0 11 10 09 10 Programmable Function Key Programming Appearance Level 0 Off 1 On Turns off or on the abili...

Страница 207: ... Set Cancel Pri vate Call Refuse 0 Off User cannot control the feature 1 On Per class of service PRG 20 06 01 this program is used to allow or de ny the stations ability to set or can cel the Private Call Refuse feature COS 1 15 1 11 10 32 25 Set Cancel Caller ID Refuse 0 Off User cannot control the feature 1 On Enable or Disable an extension abil ity to set or cancel Caller ID Refuse COS 1 15 1 1...

Страница 208: ...mbers COS 01 15 1 05 Dial Number Pre view Preset Dial 0 Off 1 On Turns off or on an extension for us ing Dial Number Preview COS 01 15 1 06 Toll Restriction Override 0 Off 1 On Turns off or on Toll Restricting Over ride Service Code 763 COS 01 15 1 21 01 07 21 07 07 Repeat Redial 0 Off 1 On Turns off or on an extension to use Repeat Redial COS 01 15 1 08 Toll Restriction Dial Block 0 Off 1 On Turn...

Страница 209: ...on that dialed E911 COS 01 15 0 17 ARS Override of Trunk Access Map 0 Off 1 On Turns off or on an extension ability to override the trunk access map programming for outgoing calls COS 01 15 0 19 Hotline for SPK 0 Off 1 On The ability of an extension to have Hotline activated or deactivated when going off hook via the speaker key COS 01 15 0 20 08 09 20 Hot Key Pad 0 Off 1 On The ability of an exte...

Страница 210: ...less of this program setting On TELPro WebPro PCPro Item name is changed to 2nd External Call from 2nd Cal DID Ovrride at R3 0 V3 0 Added COS 01 15 0 02 Caller ID Display 0 Off 1 On Turns off or on the Caller ID display at an extension COS 01 15 1 03 Sub Address Identification 0 Off 1 On Defines whether or not an extension displays the Caller Sub Address COS 01 15 0 04 Notification for Incoming Ca...

Страница 211: ...e 1 Next call When set to 0 and if set DND dur ing an incoming call the call for the terminal stops immediately When set to 1 and if set DND dur ing an incoming call the call for the terminal continues ringing and set for the next call COS 01 15 0 Conditions None Feature Cross Reference Class of Service ISSUE 3 01 SL1000 SL1100 Programming Manual 2 189 Program 20 ...

Страница 212: ... up 0 Off 1 On Turns off or on an extension to be picked up by a call pickup COS 01 15 1 05 Directed Call Pickup for Own Group 0 Off 1 On Turns off or on Directed Call Pickup for calls ringing an extension Pickup Group Service Code 856 COS 01 15 1 06 Meet Me Conference and Paging 0 Off 1 On Turns off or on an extension to use Meet Me Conference and Paging COS 01 15 1 07 Automatic Off Hook Answer 0...

Страница 213: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 191 Program 20 ...

Страница 214: ...r Without Holding 0 Off 1 On Turns off or on an extension ability to use Transfer Without Holding COS 01 15 0 08 Transfer Information Display 0 Off 1 On Turns off or on an extension ability for in coming Transfer preanswer display COS 01 15 1 09 Group Hold Initiate 0 Off 1 On Turns off or on an extension ability to ini tiate a Group Hold COS 01 15 1 10 Group Hold Answer 0 Off 1 On Turns off or on ...

Страница 215: ...0 or Deny 1 an extension user ability to set up a tandem conference call automatically when they hang up COS 01 15 0 22 Restricted Unsuper vised Conference 0 Allow 1 Deny Allow 0 or Deny 1 an extension ability to initiate an unsupervised conference COS 01 15 0 23 VE Call Forward Set Cancel 0 Off 1 On Turn on or off an extension ability to set or cancel call forwarding for a virtual exten sion COS ...

Страница 216: ...efine the Charging Cost service availability for each extension service class Input Data Class of Service Number 01 15 Item No Item Input Data Default 02 Advice of Charge ISDN AOC 0 Off 1 On COS 01 15 1 03 Cost Display TTU 0 Off 1 On COS 01 15 0 Conditions None Feature Cross Reference Class of Service SL1000 SL1100 ISSUE 3 01 2 194 Program 20 System Option Setup Program 20 ...

Страница 217: ...e Call Forwarding DND Over ride COS 01 15 1 05 Intercom Off Hook Signaling 0 Off ICM off hook signaling disabled 1 On ICM off hook signaling enabled Turns off or on an extension ability to receive off hook signals COS 01 15 1 06 Automatic Off Hook Signaling Automatic Over ride 0 Off manually 1 On automatically Allows a busy extension ability to manually 0 or automatically 1 re ceive off hook signa...

Страница 218: ...r on an extension user ability to use Selectable Display Messaging 1 20 Account Code Toll Restriction Operator Alert Restricted Oper ation Transfer 0 Off Call restricted 1 On Call routed to operator Turns off or on operator alert when an extension user improperly enters an Account Code or violates Toll Restriction COS 01 15 1 21 Extension Name 0 Off 1 On Turns off or on an extension user ability t...

Страница 219: ...on an extension user ability to set or cancel Do Not Dis turb COS 01 15 1 11 11 08 15 07 03 41 Voice Mail Mes sage Indication on DSS 0 Off 1 On Turn off or on the Voice Mail Mes sage Indication for an extension on a DSS console COS 01 15 0 42 Extension Data Swap Enabling 0 Off 1 On Turn off or on an extension user ability to use Extension Data Swap COS 01 15 1 11 15 12 44 Live Monitor En abling 0 ...

Страница 220: ...esource COS 01 15 1 53 Language Selec tion for specific extension 0 Disable 1 Enable COS 01 15 0 11 11 68 15 02 01 47 02 16 54 Call waiting for standard SIP ter minal 0 Disable 1 Enable COS 01 15 0 20 13 05 20 13 06 20 09 01 20 09 07 55 Intercom Call to Room Monitor 0 Off 1 On COS 01 15 0 Conditions None Feature Cross Reference Class of Service SL1000 SL1100 ISSUE 3 01 2 198 Program 20 System Opti...

Страница 221: ...ing or Automatic Route Selec tion ARS F Route COS 01 15 0 03 Trunk Group Access 0 Off 1 On This option enables or disables a DISA or tie trunk caller ability to access trunk groups for outside calls Service Code 804 COS 01 15 0 04 Outgoing System Speed Dial 0 Off 1 On This option enables or disables DISA or tie trunk caller ability to use the System Speed Dialing COS 01 15 0 05 Operator Calling 0 ...

Страница 222: ... Trunk Barge In 0 Off 1 On This option enables or disables a DISA or tie trunk caller ability to use the Barge In COS 01 15 0 12 Retrieve Park Hold 0 Off 1 On This option enables or disables a DISA or tie trunk caller ability to retrieve a Park Hold call COS 01 15 0 Conditions None Feature Cross Reference Class of Service Direct Inward System Access DISA SL1000 SL1100 ISSUE 3 01 2 200 Program 20 S...

Страница 223: ... Dial In in the E M Tie Line Ringing Cycle Number 1 13 8 07 Incoming Signal Type Door Box Ringing for SLT Ringing Cycle Number 1 13 2 08 Incoming Signal Type Virtual Ex tension Ring Ringing Cycle Number 1 13 8 09 Incoming Signal Type Callback Ringing Cycle Number 1 13 4 10 Incoming Signal Type Alarm for SLT Ringing Cycle Number 1 13 5 11 Incoming Signal Type VRS Wait ing Message Incoming Call Ring...

Страница 224: ... Cycle 11 On 0 25 Off 0 25 On 0 25 Off 4 25 12 On 1 0 Off 3 0 13 On 0 25 Off 0 25 On 0 25 Off 2 25 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 202 Program 20 System Option Setup Program 20 ...

Страница 225: ...characters T V t v 8 9 Enter characters W Z w z 9 0 Enter characters 0 ô õ ú å ä æ ö ü α ε θ В Enter characters π Σ σ Ω Accepts an entry only required if two letters on the same key are needed ex TOM Pressing again Space In system programming mode use the right arrow soft key instead to accept and or add a space Clear Back Clear the character entry one character at a time Flash Clear all the entri...

Страница 226: ...N UNTIL 11 MESSAGE 11 12 MESSAGE 12 13 MESSAGE 13 14 MESSAGE 14 15 MESSAGE 15 16 MESSAGE 16 17 MESSAGE 17 18 MESSAGE 18 19 MESSAGE 19 20 MESSAGE 20 Conditions Time value must be followed by two spaces Feature Cross Reference Selectable Display Messages SL1000 SL1100 ISSUE 3 01 2 204 Program 20 System Option Setup Program 20 ...

Страница 227: ... 11 01 system alarms appear on the extension assigned in this option Input Data Operator Number 1 8 Item No Item Input Data Description Default Related Program 01 Operator s Ex tension Number Up to four digits SL1000 Up to eight digits SL1100 Define the extension numbers which are to be used by operators 200 11 01 20 01 01 02 Operator Con sole 0 Normal key set 1 Special Operator Console 0 Conditio...

Страница 228: ...s DTMF re ceiver resources 10 04 Call Waiting Tone Timer 0 64800 seconds This option sets the time between Call Waiting tones This timer also sets the time between Off Hook Sig naling alerts 10 05 Multiline Confir mation Tone 0 64800 seconds 10 06 Interval of Call Waiting Tone 1 64800 seconds 10 07 Intrusion Tone Repeat Time 0 64800 seconds After a call is interrupted such as Barge In Voice Mail C...

Страница 229: ...D infor mation from Telco before connecting the CO call 5 03 Caller ID Edit Mode 0 Off 1 On If Caller ID Edit Mode is disabled 0 no access code will be added to the Caller ID If this option is enabled 1 the access code entered in PRG 10 02 02 10 02 03 will be added to the beginning of the Caller ID 0 04 Wait Facility IE Timer 0 64800 seconds This timer is used with ISDN trunks to de termine how lo...

Страница 230: ... Data Default 01 Private Call 16 Alphanumeric Characters SL1000 24 Alphanumeric Characters SL1100 UNAVAILABLE INFO 02 Call from Out of Service Area 16 Alphanumeric Characters SL1000 24 Alphanumeric Characters SL1100 OUT OF STATE 03 Call Information with Error 16 Alphanumeric Characters SL1000 24 Alphanumeric Characters SL1100 NO CALLER INFO Conditions None Feature Cross Reference Caller ID SL1000 ...

Страница 231: ...2 0 64800 seconds After the initial long toll call warning tone additional warning tones sound after this time 180 14 01 15 03 Long Conversa tion Cutoff for In coming Call 0 64800 seconds This timer determines how long the system waits before disconnecting an incoming call 0 14 01 14 04 Long Conversa tion Cutoff for Outgoing Call 0 64800 seconds This timer determines how long the system waits befo...

Страница 232: ...ds 8 03 Trunk Virtual Bridge TSP Driver 0 Disable No 1 Enable Yes Enable or disable the system to send trunk or virtual extension information to the TSP driver 0 04 The Timer that waits for an off hook for Single Line Tele phone 0 64800 seconds 30 06 3rd Party CTI IP Ad dress V3 0 Added 0 0 0 0 255 255 255 255 Read Only Displays the IP address of 3rd Party CTI Server currently connected 0 0 0 0 Co...

Страница 233: ...06 Call Proceeding Send Mode 0 Service Off 1 Service On 1 07 Local Busy Tone Mode Set When Dis connect Message Re ceived 0 Local Busy Tone Off 1 Busy Tone from NT network side 0 08 Use of Lower Layer Compatibility LLC 0 Disable Off 1 Enable On This Program must be set to 0 Disable for International Dialing when using Calling Number Presentation CPN from station 1 09 High Layer Compati bility HLC S...

Страница 234: ...Default 14 No Response Release Send 0 Off 1 On Operation mode setting for when second T303 timer expires 0 Conditions None Feature Cross Reference ISDN Compatibility SL1000 SL1100 ISSUE 3 01 2 212 Program 20 System Option Setup Program 20 ...

Страница 235: ... 20 26 Multiplier for Charging Cost to define the Multiplier for charging cost to each extension service class Input Data Service Class 01 15 Item No Item Input Data Default 01 Value 100 500 100 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 213 Program 20 ...

Страница 236: ...Tone is heard No Setting 14 01 25 20 28 03 24 02 07 24 02 10 25 07 07 25 07 08 02 Conversation Disconnect Code 0 9 Set for one digit only Input the code that can be dialed to disconnect the conversation after the Trunk to Trunk Release Warn ing Tone is heard No Setting 14 01 25 24 02 07 24 02 10 25 07 07 25 07 08 03 Conversation Continue Time 0 64800 seconds Input how long the conversation ex tend...

Страница 237: ...s for this Program one for each Night Service Mode This entry includes virtual extension numbers The details of classes are assigned by Program 20 31 Input Data Extension Number Up to four digits SL1000 Up to eight digits SL1100 Day Night Mode 1 8 Item No Item Input Data Default 01 Timer Class for Extension 0 15 0 Not assigned 0 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100...

Страница 238: ...ed You make eight entries for this Program one for each Night Service Mode The details of classes are assigned by Program 20 31 Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Day Night Mode 1 8 Item No Item Input Data Default 01 Timer Class for Trunks 0 15 0 Not assigned 0 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 216 Program 20 System Option Setup Program...

Страница 239: ...21 01 02 05 Trunk Interdigits Time Trunk I D Timer 0 64800 seconds The system waits for this time to ex pire before placing the call in a talk state Call Timer starts after time ex pires Voice Over and Barge In are not allowed until after time expires 10 21 01 03 06 Hotline Time Start Time Hot line Start 0 64800 seconds A Ringdown extension automatically calls the programmed destination af ter thi...

Страница 240: ...rs after this time This also sets how long a Transferred call waits at an exten sion forwarded to Voice Mail before routing to the called extension mail box 10 24 02 03 16 Transfer Recall Time 0 64800 seconds An unanswered transferred call re calls after this time to the extension that initially transferred it 30 24 02 04 17 DID DISA No An swer Time Dis connect or IRG or VM 0 64800 seconds A VRS D...

Страница 241: ...s the maximum length of Page announcements Affects External Paging only 1200 31 01 02 24 Mobile Extension answer time 1 64800 seconds 3 22 01 12 25 Mobile Extension callback time 1 64800 seconds 15 20 01 16 Conditions These timers are used when an extension or trunk is assigned to a class from 1 to 16 in 20 29 01 or 20 30 01 When the timer class is set to 0 the system wide timer is used All defaul...

Страница 242: ...emote Confer ence Group1 1111 Group2 2222 Group3 3333 Group4 4444 03 Max participants 0 32 Define the maximum number of partici pants of a Remote Conference 8 04 Max Conference Du ration 0 64800 seconds Define the maximum duration of a Remote Conference When this time passes the conference is disconnected by the SL1000 SL1100 7200 05 End Tone Alert Time 0 64800 seconds Determine how long prior dis...

Страница 243: ...ator Setting to assign an extension to an operator group Input Data Extension Number Up to four digits SL1000 Up to eight digits SL1100 Item No Item Input Data Default 01 Extension s Operator Setting 0 15 0 Not Set 0 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 221 Program 20 ...

Страница 244: ...L1100 Item No Item Input Data Description Default 01 Trunk s Operator Set ting 0 15 0 No Setting Allows the user to select Operator Group per trunk when DISA is being used After the user enters the 6 digit DISA password if the user dials 0 this command will decide which operator to route the call to 0 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 222 Program 20 System Opt...

Страница 245: ...tup to define the operator s in the operator group Input Data Operator Group 1 15 Operator Number 1 8 Item No Item Input Data Default 01 Operator Extension Group Setup Up to four digits SL1000 Up to eight digits SL1100 No Setting Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 223 Program 20 ...

Страница 246: ...rator telephone Input Data Operator Group 1 15 Item No Item Input Data Description Default 01 Operator Access Mode 0 Step 1 Circular Assign if the operator is called starting with the first operator every time 0 or a different operator is tried first 1 0 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 224 Program 20 System Option Setup Program 20 ...

Страница 247: ...p 1 2 3 4 5 6 7 8 9 0 Item No Item Input Data Default 01 Shortcut Operation 00 99 00 04 00 99 Function Code of Program 15 07 00 System Information 01 Function Key Setup 02 Expand Function Setup 03 Incoming Melody Setup 04 Outgoing History Refer below Default Number Message 1 40 2 85 3 00 4 27 5 28 6 16 7 17 8 03 9 35 0 38 01 02 Conditions None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 225 Prog...

Страница 248: ...Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 226 Program 20 System Option Setup Program 20 ...

Страница 249: ...tion List used with function key setting Input Data Data No 1 10 Item No Item Input Data Default 01 Function Key List 00 99 00 99 Function Code of Program 15 07 Refer below Default Number Message 1 01 2 04 3 16 4 17 5 18 6 20 7 27 8 40 9 50 10 85 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 227 Program 20 ...

Страница 250: ...Item No Item Input Data 01 Service Code Setup 0 None 1 Call Forward All 2 Night mode switching Own Group 3 BGM On Off 4 Common canceling service code 5 Walking Toll Restriction 6 Direct call pickup own group 7 Answer message waiting 8 Dial Block 9 Entry Common Abbreviated Dial Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 228 Program 20 System Option Setup Program 20 ...

Страница 251: ...ach package This Program uses ecology function Program 20 43 Input Data PKG Number 02 16 SL1000 02 09 SL1100 Item No Item Input Data Description Default Related Program 01 Ecology Mode group No 1 4 Assign Night mode group number per each package slot 1 12 02 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 229 Program 20 ...

Страница 252: ...This Program uses ecology function Program 20 43 Input Data PKG Number 02 16 SL1000 02 09 SL1100 Operation Mode 01 08 Item No Item Input Data Description Default 01 Ecology Mode 0 Cut the power 1 Power Supply Assigns the power supply mode to each package base 1 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 230 Program 20 System Option Setup Program 20 ...

Страница 253: ...ine Internal paging group number for Watching message 0 02 External Paging Group for Watch Mes sage 0 8 Define External paging group number for Watching message 0 03 VRS Message for Watch Mode 0 100 Define VRS number used for Watching message 0 04 Interval Timer for Watch Message 0 60 Define interval time for sending Watching message 0 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000...

Страница 254: ...mer 0 60 Ringing continue time for inspected exten sion 0 04 Auto Dial Number Area Setting 0 999 Speed dial number when detect no answer at extension and make emergency call 0 05 VRS Message for An swer 0 100 VRS message number when inspected ex tension answered 0 06 VRS Message for Au to Dial 0 100 VRS message number when emergency call destination answered 0 07 Time of Repeat Auto Dial 0 255 Rep...

Страница 255: ... 05 Auto Dial Number Area Setting 0 999 Define Speed dial number when sensor detects warning 0 06 VRS Message for An swer 0 100 Define VRS message number when emer gency call destination answered 0 07 Auto Dial Wait Timer 0 64800 Define wait time before making emergency auto dial 30 08 Time of Repeat Auto Dial 0 255 Define repeat number for making emer gency call 3 09 Auto Dial Calling Time 0 6480...

Страница 256: ...or Watch Mode to defines the watch mode time pattern Input Data Time Pattern 01 08 Item No Item Input Data Description Default 01 Watch Mode Time Pattern 0 Off 1 On Define watch mode on off against time pat tern 1 8 0 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 234 Program 20 System Option Setup Program 20 ...

Страница 257: ...r Security Sensor to defines the Security Sensor time pattern Input Data Time Pattern 01 08 Item No Item Input Data Description Default 01 Security Sensor Time Pattern 0 Off 1 On Define security sensor on off against time pattern 1 8 0 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 235 Program 20 ...

Страница 258: ...er ID shared group Number 01 08 Item No Item Input Data Description Default Related Program 01 Group Name Maximum 12 charac ters Caller ID shared group Name Group 1 Group Name Group 1 Group 8 Group Name Group 8 15 02 67 Default Group Group Name 1 Group1 2 Group2 3 Group3 4 Group4 5 Group5 6 Group6 7 Group7 8 Group8 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 236 Program...

Страница 259: ...er for Secuirty Sensor to set time for Security to be operational Once it reach the time the Security will starts if the Security sets manually Input Data Item No Item Input Data Default 01 Sensor delay timer 0 3600 seconds 0 Sensor will start immediately 60 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 237 Program 20 ...

Страница 260: ...econds If dial tone detection is enabled the system waits this time for the Telco to return dial tone When the time expires the system assumes dial tone is not present To disable this time and have the system wait con tinuously enter 0 5 14 02 05 05 Disconnect Time when Dial Tone not Detected 0 64800 seconds If 14 02 11 is enabled the system skips over a trunk if dial tone is not detected This opt...

Страница 261: ...et for 0 the E911 Alarm does not ring 0 11 12 56 20 08 16 14 Forced Account Code Inter digit Timer 0 64800 seconds If the user does not enter the ac count code in the amount of time specified in this program the call will be restricted 3 15 Outgoing Disable on Incoming Line Toll Restriction 0 Disable Off 1 Enable On Enable or disable the Outgoing Dis able on Incoming Line feature 0 15 01 05 21 01 ...

Страница 262: ...Feature Cross Reference Central Office Calls Placing SL1000 SL1100 ISSUE 3 01 2 240 Program 21 Outgoing Call Setup Program 21 ...

Страница 263: ...am 14 06 routes to extensions Input Data Extension Number Maximum four digits SL1000 Maximum eight digits SL1100 Day Night Mode 1 8 Item No Item Input Data Default Related Program 01 Route Table Number 0 25 0 No Setting Calls will not route 1 14 06 14 01 07 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 241 Program 21 ...

Страница 264: ...ic External Call Forward The Route Table is set in Program 14 06 Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Day Night Mode 1 8 Item No Item Input Data Default Related Program 01 Route Table Number 0 25 0 No Setting 0 14 06 14 07 01 Conditions None Feature Cross Reference Trunk Group Routing SL1000 SL1100 ISSUE 3 01 2 242 Program 21 Outgoing Call Setup Program 21 ...

Страница 265: ...ined in Program 21 05 and 21 06 A telephone and a trunk will have a Restriction Class The higher class applies for outgoing calls Input Data Extension Number Maximum four digits SL1000 Maximum eight digits SL1100 Day Night Mode 1 8 Item No Item Input Data Default Related Program 01 Restriction Class 1 15 Toll Class 1 15 2 14 01 08 21 05 Conditions None Feature Cross Reference None ISSUE 3 01 SL100...

Страница 266: ... Program 21 06 02 0 21 06 02 04 Maximum Num ber of Digits Ta ble Assignment 0 No Table Applied 1 4 Tables 1 4 Defined in PRG 21 06 03 Select the table defined in 21 06 03 to be used to determine the maximum number of digits al lowed for outgoing calls 0 21 06 03 05 Common Permit Code Table 0 Unassign No com mon permit table ap plied 1 Assign Table in PRG 21 06 04 is ap plied It chooses whether the...

Страница 267: ... Toll Restricts calls over PBX trunks If you enable PBX Toll Re striction the system begins Toll Re striction after the PBX access code The user cannot dial a PBX exten sion If you disable PBX Toll Restric tion the system only restricts calls that contain the PBX access code The system does not restrict calls to PBX extensions Refer to the PBX compatibility feature Make sure Program 21 05 04 Maxim...

Страница 268: ...is option selects the maximum number of digits allowed in outgoing calls for each ta ble caption table 1 4 4 30 Tables 1 4 30 04 Common Permit Code Table This option lets you program the Common Permit Code Table This table contains up to 10 codes you com monly allow users to dial caption table 1 10 Dial Up to four digits Tables 1 10 No Set ting 05 Common Restriction Table This option lets you prog...

Страница 269: ... 04 the system only Toll Restricts calls that contain the ac cess code Always program this option when the system is behind a PBX even if you don t want to use Toll Restriction PBX Access Codes can have up to two dig its using 0 9 and LINE KEY 1 don t care When using Account Codes do not use an asterisk in a PBX access code Otherwise after the the trunk stops sending digits to the central office E...

Страница 270: ...ur digits using any combination of 0 9 and Each extension can have a separate code or many extensions can share the same override code Input Data Extension Number Maximum four digits SL1000 Maximum eight digits SL1100 Item No Item Input Data Default Related Program 01 Password Four Digits Fixed No Setting 21 01 07 20 08 06 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 248...

Страница 271: ...erval Time 0 64800 seconds Set the time between Repeat Redial at tempts 60 03 Repeat Dial Calling Timer 0 64800 seconds After dialing the trunk call Repeat Redial maintains the call after this time After this time the system terminates the call waits the Repeat Redial Time Timer 02 and tries again 30 04 Time for Send Busy Tone for ISDN Trunk 0 64800 seconds Sets the time sec to send out Busy Tone ...

Страница 272: ...lass of Service when the Dial Block feature is used 1 02 Supervisor Password 0 9 4 digit fixed Assign a 4 digit password to be used by the supervisor to enable or disable Dial Block for other extensions No Setting Conditions This function works by password and Class of Service control the supervisor is not an assigned extension If Dial Block is available for all Classes of Service everyone may bec...

Страница 273: ... each extension when the extension is set for Dial Block Restriction If this data is 0 Toll Restriction Class follows Program 21 09 01 Input Data Extension Number Maximum four digits SL1000 Maximum eight digits SL1100 Item No Item Input Data Default 01 Toll Restriction Class 0 1 15 0 No Setting 0 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 251 Program...

Страница 274: ... Data Default Related Program 01 Hotline Destination Number 1 0 Pause Hook Flash Code to wait for answer supervision maximum 36 digits No Setting 20 08 09 21 01 09 Conditions The code is used to make an outbound call automatically to a DISA Trunk or to VM Auto Attendant This code can only be used on ISDN outbound calls Internal calls and analog outbound calls are not supported Feature Cross Refere...

Страница 275: ...ng Party Number is assigned in both Programs 21 12 and 21 13 the system sends the data in Program 21 13 Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Item No Item Input Data Description Default 01 Calling Party Number Data Maximum of 16 digits 0 9 Most Telco s will only ac cept 10 digits This program is used to assign a calling party number per trunk If CPN information is programmed o...

Страница 276: ...Calling Number assigned Program 21 13 the system sends the calling number for the ISDN trunk defined in Program 21 12 If a Calling Party Number is assigned in both Programs 21 12 and 21 13 the system sends the data in Program 21 13 Input Data Extension Number Maximum four digits SL1000 Maximum eight digits SL1100 Item No Item Input Data Default 01 Calling Party Number Data Maximum of 16 digits 0 9...

Страница 277: ...estriction Class for Walking Toll Restriction Each code has six digits using any combination of 0 9 and Input Data ID Table Number 1 100 Item No Item Input Data Default 01 User ID Dial Six digits No Setting 02 Walking Toll Restriction Class Number 1 15 15 Conditions None Feature Cross Reference Code Restriction Toll Restriction ISSUE 3 01 SL1000 SL1100 Programming Manual 2 255 Program 21 ...

Страница 278: ...when setting up alternate trunk codes Refer to 14 06 Trunk Group Routing on page 2 119 to set up the trunk routes When entering data for this option enter the route number or 0 to prevent routing Input Data Extension Number Maximum four digits SL1000 Maximum eight digits SL1100 Day Night Mode 1 8 Item No Item Input Data Default 01 Route Table Number 0 25 0 No Setting Calls will not route 0 Conditi...

Страница 279: ...r Setup for Trunk set the SIP calling party number for individual trunks Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Item No Item Input Data Default Related Program 01 Calling Party Number V2 0 Changed Up to 16 digits 1 0 No Setting 15 01 04 20 08 13 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 257 Program 21 ...

Страница 280: ...t to the exchange when the caller places an outgoing call When the Calling Party Number is assigned by Programs 21 17 21 18 and 21 19 the system uses the data in Programs 21 18 and 21 19 Input Data Extension Number Up to four digits SL1000 Up to eight digits SL1100 Item No Item Input Data Default 01 Calling Party Number Up to 16 digits 1 0 No Setting Conditions None Feature Cross Reference None SL...

Страница 281: ...tension to set the SIP calling party number for an individual extension Input Data Extension Number Up to four digits SL1000 Up to eight digits SL1100 Item No Item Input Data Default Related Program 01 Calling Party Number Up to 16 Digits 1 0 No Setting 15 01 04 20 08 13 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 259 Program 21 ...

Страница 282: ...all Discernment Setup for Extension to set the SIP Trunk Call Discernment Input Data Extension Number Up to four digits SL1000 Up to eight digits SL1100 Item No Item Input Data Default 01 Discernment Tone 0 Off 1 On 1 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 260 Program 21 Outgoing Call Setup Program 21 ...

Страница 283: ... Station Restriction Class The higher class is applied Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Day Night Mode 1 9 9 Power Failure mode Item No Item Input Data Description Default Related Program 01 Restriction Class 1 15 Toll Class 1 15 Per Day Night Mode assign a toll re striction class to each trunk It is recommended to not use class 2 because by default all stations are assig...

Страница 284: ... Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Item No Item Input Data Description Default 01 CO MWI Call Back En abling 0 No VMWI Service 1 Enable VMWI Serv ice Enable or Disable CO MWI Call Back 0 02 CO MWI Call Back Number Area Setting 0 999 Define the Speed Dial Bin number for MWI Call Back 999 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 262 Program 21 ...

Страница 285: ...or Emergency number data First digit of dialing data should be same as trunk access code Input Data Item No Item Input Data Description Default 01 Dialing Number 1 0 maximum 16 digits Define the Emergency Number Data No Setting Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 263 Program 21 ...

Страница 286: ...ltiline telephone longer than this interval the system changes the ring cadence This indi cates to the user that the call has been ringing too long 60 22 01 02 04 DIL No Answer Recall Time 0 64800 seconds 0 No Overflow A DIL that rings its programmed destination longer than this interval diverts to the DIL No Answer Ring Group set in Program 22 08 0 06 DID Ring No An swer Time 0 64800 seconds In s...

Страница 287: ...ing duration time of the Auto Attendant Queuing The message is repeatedly sent out during the specified time 20 22 14 06 22 15 06 41 11 06 12 Mobile Extension answer time 0 64800 seconds 3 15 22 04 Conditions None Feature Cross Reference Central Office Calls Answering ISSUE 3 01 SL1000 SL1100 Programming Manual 2 265 Program 22 ...

Страница 288: ... feature type for the trunk you are program ming 0 14 04 Conditions When connecting to T1 trunks after changing Program 22 02 01 to match the Telco connected T1 service type the T1 cable or the T1 unit must be unplugged and then reconnected for the T1 unit to sync When the trunk type is set to 3 DID the DID Transfer to Destination in 22 11 04 for each DID feature is not supported This feature is s...

Страница 289: ... Tone Pattern 4 1 SL1000 4 Ring Tone Pattern 5 2 SL1000 5 Ring Tone Pattern 6 3 SL1000 6 Ring Tone Pattern 7 3 SL1000 7 Not Used SL1000 8 Not Used SL1000 0 Ring Tone Pattern 1 SL1100 1 Ring Tone Pattern 2 SL1100 2 Ring Tone Pattern 3 SL1100 3 Ring Tone Pattern 4 SL1100 4 Melody 1 SL1100 5 Melody 2 SL1100 6 Melody 3 SL1100 7 Melody 4 SL1100 8 Melody 5 SL1100 9 Ring Tone Pattern 5 V3 0 Added SL1100 ...

Страница 290: ...2 High Middle Low 1100Hz 660Hz 520Hz 1400Hz 760Hz 660Hz 8Hz 8Hz 8Hz Pattern 3 High Middle Low 2000Hz 1400Hz 1100Hz 760Hz 660Hz 540Hz 16Hz 16Hz 16Hz Pattern 4 High Middle Low 2000Hz 1400Hz 1100Hz 760Hz 660Hz 540Hz 8Hz 8Hz 8Hz Pattern 5 V3 0 Added High Middle Low 1400Hz 760Hz 660Hz 540Hz 540Hz 540Hz 16Hz 16Hz 16Hz Pattern 6 V3 0 Added High Middle Low 1400Hz 760Hz 660Hz 540Hz 540Hz 540Hz 8Hz 8Hz 8Hz ...

Страница 291: ...Incoming Ring Group IRG can have up to 32 extension numbers assigned There are 25 available Ring Groups Input Data Incoming Ring Group Number 01 25 Item No Item Input Data Description Default Related Program 01 Extension Num ber Maximum four Digits SL1000 Maximum eight Digits SL1100 Use this program to assign exten sions up to 32 to Ring Groups Calls ring extensions according to Ring Group program...

Страница 292: ... Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Day Night Mode 1 8 Item No Item Input Data Description Default Related Program 01 Incoming Group Number 0 No Setting 01 25 Incoming Group 102 VMI Use this program to assign Normal Ring Trunks 22 02 to Incoming Ring Groups 22 04 1 22 04 22 06 Conditions None Feature Cross Reference Ring Groups SL1000 SL1100 ISSUE 3 01 2 270 Program 22 Inco...

Страница 293: ...ing for the Normal Incoming Ring Mode Input Data Extension Number Maximum four digits SL1000 Maximum eight digits SL1100 Day Night Mode 1 8 Item No Item Input Data Default Related Program 01 Incoming Group Number 0 No Ring 1 Ring 1 22 04 22 05 Conditions None Feature Cross Reference Central Office Calls Answering ISSUE 3 01 SL1000 SL1100 Programming Manual 2 271 Program 22 ...

Страница 294: ...to designate a trunk as a DIL You can make eight DIL assignments one for each Night Service mode Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Day Night Mode 1 8 Item No Item Input Data Default 01 Number of Transferring Destina tion Assign extension or department group number for DIL trunk Extension Number maximum four digits SL1000 maximum eight digits SL1100 No Setting Conditions Pr...

Страница 295: ...am 22 01 04 DIL Delayed Ringing can also reroute outside calls ringing a Ring Group Make eight assignments one for each Night Service mode Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Day Night Mode 1 8 Item No Item Input Data Default 01 Incoming Group Number 0 No Setting 01 25 Incoming Group 102 VMI Only Group01 has 200 SL1000 Conditions None Feature Cross Reference Direct Inward Li...

Страница 296: ...In tercept Ring Group on page 2 280 If the system receives a DID that is not routed this program sets what the system does with the call If the setting data is a 0 Disconnect the system will deny the call If the setting data is a 1 Transfer the call will be routed to the ring group specified in PRG 22 12 01 0 03 Sub Addressing Mode 0 Extension Specify Intercom 1 DID Conversion Ta ble 0 04 DID Rece...

Страница 297: ...Feature Cross Reference Direct Inward Dialing DID ISSUE 3 01 SL1000 SL1100 Programming Manual 2 275 Program 22 ...

Страница 298: ...rsion Table Area Number 01 20 Item No Item Input Data Default 01 1st Area Setup Start Address 0 800 0 No Setting Refer below 1st Area Setup End Address 2nd Area Setup Start Address 2nd Area Setup End Address Default Conversion Ta ble Area 1st 2nd Start Table End Table Start Table End Table 1 1 200 0 0 2 201 400 0 0 3 401 600 0 0 4 601 800 0 0 5 0 0 0 0 20 0 0 0 0 Conditions None Feature Cross Refe...

Страница 299: ...e times Key for Entering Names When entering names in the procedures below refer to this chart Names can have up to 12 digits Use this keypad digit When you want to 1 Enter characters 1 _ Á À Â Ã Å Æ Ç É Ê ì ó 0 2 Enter characters A C a c 2 3 Enter characters D F d f 3 4 Enter characters G I g i 4 5 Enter characters J L j l 5 6 Enter characters M O m o 6 7 Enter characters P S p s 7 8 Enter charac...

Страница 300: ...S 401 DISA 501 599 DISA VRS Message No 1000 1999 Common ABB Dial 000 999 0 06 Transfer Destination Number 2 0 No setting 01 25 Incoming Ring Group 102 VM 201 232 Department Group 400 VRS 401 DISA 501 599 DISA VRS Message No 1000 1999 Common ABB Dial 000 999 400 Allow the outside party to dial a dif ferent extension number in the translation table for example ring no answer to a di aled number the ...

Страница 301: ... 05 then Program 22 11 06 then if Program 22 11 11 is enabled the calls will overflow from Transfer Destination Num ber 2 to the destination programmed in PRG 22 12 01 If the terminal is in Power Cutting mode from the ecology feature this command will not be applied 1 Default The default value of Programs 22 11 01 and 22 11 02 is shown as below Conversion Table Received number Target number 1 00 2...

Страница 302: ...ogram 22 11 based on the table assigned to the DID trunk If Programs 22 11 05 and 22 11 06 are set the priority of transferring is in this order Program 22 11 05 Program 22 11 06 Program 22 12 For busy and no answer calls if the first and third destinations are programmed but the second destination is not the incoming call goes to the third destination after the first destination If the first and ...

Страница 303: ...in their own group If you have more than one type of DID trunk put each type in a separate Trunk Group For each Trunk Group you make a Translation Table entry for each Night Service mode Input Data Trunk Group Number 1 25 Day Night Mode 1 8 Item No Item Input Data Default 01 Conversion Table Area Number 0 20 0 No Setting 1 Conditions None Feature Cross Reference Direct Inward Dialing DID ISSUE 3 0...

Страница 304: ...t 0 255 time This is the number of times the 1st Delay Message is played If set to 0 the 1st De lay Message is not played 0 04 2nd Delayed Message Number 0 101 0 No Message 101 Fixed Message VRS message that is used for the 2nd De layed Message 0 05 2nd Delayed Message Sending Count 0 255 time This is the number of times the 2nd Delay Message is played If set to 0 the 2nd De lay Message is not pla...

Страница 305: ...st Delayed Message Sending Count 0 255 time This is the number of times the 1st Delay Message is played If set to 0 the 1st De lay Message is not played 0 04 2nd Delayed Message Number 0 101 0 No Message 101 Fixed Message VRS message that is used for the 2nd De layed Message 101 05 2nd Delayed Message Sending Count 0 255 time This is the number of times the 2nd Delay Message is played If set to 0 ...

Страница 306: ...all Refuse Input Data Item No Item Input Data Description Default 01 Speed Dial Group Number 0 32 0 No Group Assigned Caller ID refuse will not function This program is used to assign a speed di al group 1 32 to be used for the caller ID refuse number matching storage 0 Conditions None Feature Cross Reference Department Group SL1000 SL1100 ISSUE 3 01 2 284 Program 22 Incoming Call Setup Program 22...

Страница 307: ... Received Dial Up to eight digits No Setting 02 Start of Time 0000 2359 Time Define the Starting Time for each DID Translation table in PRG 22 17 01 0000 03 End of Time 0000 2359 Time Define the Ending Time for each DID Translation table in PRG 22 17 01 0000 04 Dial In Conversion Table Number 1 800 These are the table entries in PRG 22 11 0 05 Day of week V2 0 Added 1 Sun 2 Mon 3 Tue 4 Wed 5 Thu 6...

Страница 308: ... Private caller to a VRS message to refuse the call This program can also be used to route the Private caller to an internal destination PRG 22 18 02 or a Ring Group PRG 22 04 0 14 01 27 15 02 02 40 10 06 02 Destination Num ber 1 Internal Dial up to 36 digits 0 9 P R 2 Incoming Ring Group 0 25 No Setting 14 01 27 15 02 02 40 10 06 03 Incoming Ring Pattern Incoming Ring Pattern 0 9 SL1000 Incoming ...

Страница 309: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 287 Program 22 ...

Страница 310: ...ialing for each DID table entry This option is used for Latin America only Input Data Conversion Table Number 1 800 Item No Item Input Data Default 01 DID MFC Dialing Category 0 Normal 1 Without Charge 2 Called Party Release 0 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 288 Program 22 Incoming Call Setup Program 22 ...

Страница 311: ...to set flexible ringing by Caller ID per timer pattern mode Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Day Night Mode 01 08 Item No Item Input Data Default Related Program 01 Flexible Ringing 0 Disable 1 Enable 1 13 04 14 01 30 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 289 Program 22 ...

Страница 312: ...ble Call Pickup Groups Input Data Extension Number Maximum four digits SL1000 Maximum eight digits SL1100 Group Number 1 32 Item No Item Input Data Description Default Related Program 01 Priority 1 999 Use this program to assign exten sions to Call Pickup Groups other than the extension group set up by a Program 16 02 1 xxx Note default value follows the port order of PRG11 02 or PRG11 04 11 12 26...

Страница 313: ...tension user ringing calls however always have priority over calls ringing other co worker extensions Refer to the Line Preference feature in the SL1000 SL1100 Features and Specifications Manual for more information Make one entry for each Night Service mode Input Data Extension Number Maximum four digits SL1000 Maximum eight digits SL1100 Day Night Mode 1 8 Item No Item Input Data Description Def...

Страница 314: ...m eight digits SL1100 Priority Order 1 4 Item No Item Input Data Description Default Related Program 01 Extension Group Number 0 32 0 No Setting When an extension has a virtual ex tension assigned to a Programma ble Function Key this program de termines the priority for automatical ly answering the ringing calls when the handset is lifted If 0 or 00 is se lected when the user lifts the hand set th...

Страница 315: ...s until a user answers the call 30 03 Exclusive Hold Recall Time 0 64800 seconds A call left on Exclusive Hold recalls the extension that placed it on Hold after this time 90 04 Exclusive Hold Recall Callback Time 0 64800 seconds An Exclusive Hold Recall rings an extension for this time If not picked up the call goes back on System Hold 30 05 Forced Release of Held Call 0 64800 seconds Depending o...

Страница 316: ...red call waits at an exten sion forwarded to Voice Mail before routing to the called extension mail box 10 20 31 15 04 Transfer Recall Time 0 64800 seconds An unanswered transferred call re calls to the extension that initially transferred it after this time 30 20 31 16 05 Message Wait Ring Interval Time 0 64800 seconds For Single Line Telephones SLTs without message waiting lamps this is the time...

Страница 317: ...runk Transfer 0 64800 seconds 0 14 01 26 13 Hook Flash Sending Timer When the Sys tem Answers Au tomatically 0 64800 seconds Time before sending the hook flash for Call Forward Centrex 2 15 SIP Out of Range Timer V3 0 Add ed 0 30 seconds When not receiving any response within this timer setting the system determines that the SIP terminal is out of range When set to 0 timer is invalid 4 Conditions ...

Страница 318: ...rked in orbit by an extension user in own group Input Data Extension Number Maximum four digits SL1000 Maximum eight digits SL1100 Item No Item Input Data Description Default Related Program 01 Park Group Num ber 1 64 Assign an extension to a Park Group The system allows a total of 64 Park Groups 1 15 07 01 Conditions None Feature Cross Reference Park SL1000 SL1100 ISSUE 3 01 2 296 Program 24 Hold...

Страница 319: ...r Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Day Night Mode 1 8 Item No Item Input Data Default Description Related Program 01 Speed Dial Area Number 0 999 999 The destination telephone number of the Trunk to Trunk Transfer uses the num ber registered into the Speed Dial Use this program to setup the Speed Dial Bin Number 11 10 08 13 04 24 05 Conditions None Feature Cross Reference...

Страница 320: ... Groups Input Data Extension Group Number 01 32 Day Night Mode 1 8 Item No Item Input Data Description Default Related Program 01 Speed Dial Area Number 0 999 The Speed Dialing area is used to program the destination number of the transferred telephone number when a Department Group call is transferred using the Trunk to Trunk Forwarding feature 999 11 11 27 13 04 24 04 Conditions None Feature Cro...

Страница 321: ... Call Forward All 4 Call Forward Busy No Answer 5 Call Forward Busy 0 02 CO Call Forwarding Destination for Both Ring All Call No Answer Maximum of 36 digits 0 9 P R V1 5 Changed Only ISDN uses the symbol No Setting 03 Intercom Call Forwarding Destina tion for Both ring All Call No An swer Maximum of 36 digits 0 9 P R V1 5 Changed No Setting 04 CO Call Forwarding Busy Destina tion Maximum of 36 di...

Страница 322: ...Feature Cross Reference Call Forwarding Off Premise SL1000 SL1100 ISSUE 3 01 2 300 Program 24 Hold Transfer Setup Program 24 ...

Страница 323: ...r 001 126 SL1000 001 096 SL1100 Item No Item Input Data Default Related Program 01 VRS DISA Dial In Mode 0 Extension Number Service Code Specify In tercom 1 Use Dial Conversion Table 0 22 11 02 DISA User ID 0 Off 1 On 1 25 08 03 VRS DISA Transfer Alarm 0 Normal Off 1 Alarm On 0 Conditions None Feature Cross Reference Direct Inward System Access DISA ISSUE 3 01 SL1000 SL1100 Programming Manual 2 30...

Страница 324: ...ned as a VRS DISA Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Day Night Mode 1 8 Item No Item Input Data Additional Data Default 01 Message Talkie Source 0 No Talkie 1 VRS 3 SLT 1 01 100 VRS Message Number 3 01 32 Station Group Number Talkie Type 1 Additional Data 1 Conditions None Feature Cross Reference Direct Inward System Access DISA SL1000 SL1100 ISSUE 3 01 2 302 Program 25 VRS...

Страница 325: ...ansfer to an alternate destination a ring group or voice mail When setting the DISA and DID Operating Mode make an entry for each Night Service mode Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Day Night Mode 1 8 Item No Item Input Data Default Related Program 01 Incoming Group Number 0 Disconnect 01 25 Incoming Ring Group 102 VMI 104 Assign the Speed Dial Number V3 0 Add ed 0 22 04 ...

Страница 326: ...connect 0 or Transfer to an alternate destination a ring group or voice mail When setting the DISA and DID Operating Mode make an entry for each Night Service mode Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Day Night Mode 1 8 Item No Item Input Data Default Related Program 01 Incoming Group Number 0 Disconnect 01 25 Incoming Ring Group 102 VMI 104 Assign the Speed Dial Number V3 0 ...

Страница 327: ...00 the outside caller hears if they dial incorrectly If you enter 0 i e no error message the call reroutes according to Programs 25 03 and 25 04 For each trunk make a separate entry for each Night Service mode Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Day Night Mode 1 8 Item No Item Input Data Default 01 VRS Message Number 0 100 0 No Setting 0 Conditions None Feature Cross Referen...

Страница 328: ...can be assigned for each Automated Attendant message Example Message Number 01 Destination 2 Next Message Number 0 Dial 399 In this example when 2 is dialed by an outside caller the system transfers the call to 399 This means that extension 200 299 cannot receive calls from VRS DISA users during after VRS Message 01 Input Data Attendant Message Number 01 100 Received Dial 1 9 0 Item No Item Input ...

Страница 329: ...ot be able to dial individual extensions or lines if the same first digit is defined here Feature Cross Reference Direct Inward System Access DISA Voice Response System VRS ISSUE 3 01 SL1000 SL1100 Programming Manual 2 307 Program 25 ...

Страница 330: ...k when the call may go to Incoming Ring Group of Pro grams 25 03 and 25 04 This setting determines how long the call is ring ing in the IRG 60 20 31 18 04 Calling Time to Automatic An swering Tele phone Set 0 64800 seconds Set the answering waiting time of the automatic answering extension when an incoming DID trunk call is received 10 05 Duration Time for Guidance Message by Au tomatic Answer ing...

Страница 331: ...22 11 VRS DISA An swer Delay Time 0 64800 seconds Sets up the time the system waits after receiving an incoming VRS DISA call before the system auto matically answers the call 0 13 VRS DISA Busy Tone Interval 0 64800 seconds If a DISA caller dials a busy exten sion and Program 25 04 0 the system plays busy tone for this time before disconnecting 5 14 Delayed VRS An swer Time 0 64800 seconds Assign...

Страница 332: ...SA password for each user There are 15 users each with one 6 digit password Input Data DISA User Number 01 15 Item No Item Input Data Default 01 Password Dial Fixed six digits 0 9 No Setting Conditions None Feature Cross Reference Direct Inward System Access DISA SL1000 SL1100 ISSUE 3 01 2 310 Program 25 VRS DISA Setup Program 25 ...

Страница 333: ...Class of Service with the call Assign the DISA Class of Service options in Program 20 14 When programming DISA Class of Service make one entry for each Night Service mode Input Data DISA User Number 1 15 Day Night Mode 1 8 Item No Item Input Data Default 01 Function Class 1 15 1 Conditions DISA Class of Service cannot be 0 Program 20 06 cannot be used to assign Class of Service to DISA trunks Feat...

Страница 334: ...to dial 9 in Program 20 14 02 Assign a route to each DISA Class of Service 1 15 The system assigns a DISA Class of Service to a call based on the password the DISA caller dials When programming make a separate entry for each Night Service Mode Input Data DISA User Number 1 15 Day Night Mode 1 8 Item No Item Input Data Default 01 Route Table Number 0 25 0 No Setting 1 Conditions None Feature Cross ...

Страница 335: ...triction Class assigned to a DISA call is based on the DISA Class of Service and user which is determined by the password the caller dials When programming make a separate entry for each Night Service mode Input Data DISA User Number 1 15 Day Night Mode 1 8 Item No Item Input Data Default 01 Toll Restriction Class 1 15 2 Conditions Program 21 05 cannot be used to assign Toll Restriction to DISA tr...

Страница 336: ...word the caller dials When programming make a separate entry for each Night Service Mode Use Program 11 09 02 to set the Alternate Trunk Access Code Use Program 14 06 to set trunk routes Input Data DISA User Number 1 15 Day Night Mode 1 8 Item No Item Input Data Default 01 Route Table Number 0 25 0 No Setting 0 Conditions You cannot use Program 21 15 to assign alternate trunk routing to DISA trunk...

Страница 337: ...ram also is used to define additional DISA call options Input Data Item No Item Input Data Description Default 01 VRS Message Access Password 1 9 0 Fixed six digits Enter the password DISA callers must dial before the system allows them to record listen to and or erase the VRS messages 000000 Conditions None Feature Cross Reference Direct Inward System Access DISA Voice Response System VRS ISSUE 3...

Страница 338: ...nk Port Number 001 126 SL1000 001 096 SL1100 Day Night Mode 1 8 Item No Item Input Data Default Related Program 01 DISA Transfer Target Area At Wrong Dial Speed Dial bin number 0 999 999 25 03 01 02 DISA Transfer Target Area At No Answer or Busy Speed Dial bin number 0 999 999 25 04 01 Conditions Related to Programs 25 03 01 25 04 01 Feature Cross Reference Direct Inward System Access DISA Voice R...

Страница 339: ...been received If ARS is enabled at Site B this time can be programmed for 5 500 ms at Site A If ARS is disa bled and Site B is using F Route for outbound dialing this time should be programmed for 30 three sec onds at Site A 30 20 03 04 03 ARS Misdialed Number Han dling 0 Route to Trunk Group 1 1 Play Warning Tone to Dialer If a user dials a number not pro grammed in ARS this option deter mines if...

Страница 340: ...Feature Cross Reference Automatic Route Selection ARS F Route SL1000 SL1100 ISSUE 3 01 2 318 Program 26 ARS Service Least Cost Routing Program 26 ...

Страница 341: ...ype 0 No Service Call Restricted 1 Route to Trunk Group 2 Select F Route Access 0 03 Additional Data Service Number If Service Type 1 in 26 02 Select Trunk Group Number 0 25 Trunk Group Number 0 No Route If Service Type 2 in 26 02 F Route Time Schedule Not Used 0 100 F Route Table Number Refer to Program 44 05 ARS F Route Table on page 2 402 F Route Time Schedule Used 0 100 F Route Selection Numbe...

Страница 342: ...Feature Cross Reference Automatic Route Selection ARS F Route SL1000 SL1100 ISSUE 3 01 2 320 Program 26 ARS Service Least Cost Routing Program 26 ...

Страница 343: ...ts or execute the code that follows For example D041234 outdials 1234 Valid entries are 0 9 Wnn wait nn seconds and P pause Each digits code counts as a digit So for example if a P was added for a pause the entry would look like D05P1234 Wnn Wait nn seconds P Pause in analog trunk R Redial the initially dialed number including any modifications E End of Dial Treatment All Dial Treatments must end ...

Страница 344: ...n ARS F Route uses ARS Class of Service when determining how to route extension calls Input Data Extension Number Up to four digits SL1000 Up to eight digits SL1100 Day Night Mode 1 8 Item No Item Input Data Default 01 Class 0 16 0 No Class 0 Conditions None Feature Cross Reference Automatic Route Selection ARS F Route SL1000 SL1100 ISSUE 3 01 2 322 Program 26 ARS Service Least Cost Routing Progra...

Страница 345: ...o the Indirect Carrier No Setting 03 Authorization Code Table 0 10 0 No Authorization code Enter the table number that contains the correct Authorization code 0 04 Cost Center Code 0 Not Used 1 Used Optionally enter a cost center code 0 Conditions The settings must comply with the requirements of the Indirect Carrier The operation of the symbol within the Access Code depend on the type of trunk Fo...

Страница 346: ...d if set in Program 26 05 03 Input Data Authorization Table Number 1 10 Item No Item Input Data Default 01 Authorization Code Up to 10 digits No Setting Conditions The settings must comply with the requirements of the Indirect Carrier The Authorization Code is used by the Indirect Carrier to identify the customer for billing purposes Feature Cross Reference LCR Least Cost Routing SL1000 SL1100 ISS...

Страница 347: ...rted if set in Program 26 05 04 Input Data Extension Number Up to four digits SL1000 Up to eight digits SL1100 Item No Item Input Data Default 01 Cost Center Code Up to 8 digits Extension Number Conditions The settings must comply with the requirements of the Indirect Carrier The cost Center code is used by the Indirect Carrier to identify the individual user for billing purposes Feature Cross Ref...

Страница 348: ... 10 Item No Item Input Data Description Default 01 Manual Override Code Maximum 4 digits 0 9 This code is dialed by the user to bypass the automatic selection No Setting 02 Carrier Table No Carrier Table number 0 25 The carrier table number of Program 26 05 0 Conditions The override code must begin with a digit 1 or it will not be checked against this table There can are also exemptions to this ta...

Страница 349: ...al Override Exemption Table Number 1 25 Item No Item Input Data Default 01 Exemption Number Maximum 4 digits 0 9 Do not include the Access Code Table 1 999 Table 2 112 Table 3 25 No Set ting Conditions If the number dialed by the user corresponds to an entry in Program 26 09 the Aspire will delete the Manual Access code Program 26 08 and route the call to the direct carrier If the number specifies...

Страница 350: ... for Alternate carrier access which is referred from Program 26 03 Input Data Transit Network ID Table 1 4 Item No Item Input Data Default 01 Transit Network ID Carrier ID 0000 9999 Fixed four digits or No Setting Table No 1 4 No Setting Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 328 Program 26 ARS Service Least Cost Routing Program 26 ...

Страница 351: ...on 0 System Default 1 Unknown 2 International No 3 National No 4 Network Specific No 5 Subscriber No 6 Abbreviated No This setting is used by Programs 26 02 07 and 44 05 11 to determine ISDN element 0 02 Called Party number Numbering Plan Iden tification Selection 0 System Default 1 Unknown 2 ISDN Plan 3 Data Plan 4 Telex Plan 5 National Standard Plan 6 Private Plan This setting is used by Program...

Страница 352: ... option applies to all the system DSS Consoles The available options are Regular Business Mode 0 Hotel Mode 1 Input Data DSS Console Number 01 12 Item No Item Input Data Default 01 DSS Operation Mode 0 Business Mode 1 Hotel Mode 0 Conditions None Feature Cross Reference Direct Station Selection DSS Console Hotel Motel SL1000 SL1100 ISSUE 3 01 2 330 Program 30 DSS DLS Console Setup Program 30 ...

Страница 353: ... Console s combination is called a Console Number There are 12 Console Numbers 01 12 Console Numbers can be assigned to extensions When entering data the assignment for Console Number 1 is normally made first Input Data 60 button DSS Console Number 01 12 Item No Item Input Data Description Default 01 Extension Number Up to four digits SL1000 Up to eight digits SL1100 The extension number for the m...

Страница 354: ...nected either by phone or using the WebPro or PC Program you may need to unplug the DSS and plug it back in to reset the console lamping Input Data Index 1 DSS Console Number 01 12 Index 2 Item No Key Number Function Number Additional Data 01 001 060 SL1000 001 114 SL1100 0 99 0 99 General Functional Level 00 99 Appearance Functional Level Refer to Table 2 8 Function Number List on page 2 332 Tabl...

Страница 355: ...ext Message Setup Message Numbers 01 20 On Red Setup 19 External Group Paging External Paging Num ber 1 6 On Red Active 20 External All Call Paging On Red Active 21 Internal Group Paging Internal Paging Num ber 01 32 On Red Active 22 Internal All Call Paging None 23 Meet Me Answer to In ternal Paging None 24 Call Pickup None 25 Call Pickup for Another Group None 26 Call Pickup for Specified Group ...

Страница 356: ...ing Group Num ber 01 25 On Red Setup 53 Automatic Answer with Delay Message Starting On Red Delay Message Answering 54 External Call Forward by Door Box Setup On Red Setup 55 Extension Name Edit None 56 General Purpose LED Operation 001 100 Red On Off 57 General Purpose LED Indication 001 100 Red On Off 58 Department Incoming Call Immediate Extension Group Number 01 32 Slow Blink Red Set Off Cance...

Страница 357: ...calls SL1100 80 Tandem Ringing Set Up Key 0 Cancel 1 Set Extension Number to Tandem Ring 4 dig its SL1000 Extension Number to Tandem Ring 8 dig its SL1100 On Red Master Side Slow Blink Red Slave Side 81 Automatic Transfer to Transfer Key Trunk Line No 001 126 SL1000 Trunk Line Number 001 096 SL1100 Off Cancel Slow Blink Red Set 83 Conversation Recording Function 0 Pause 1 Re record 2 Address 3 Era...

Страница 358: ...oor Box Access Key Doorphone No 1 8 SL1000 Doorphone No 1 6 SL1100 On Red Door Box Busy Off Door Box Idle Fast Blink Red Door Box Incoming 98 Message Waiting Indi cation Key None ON New Message OFF No Message 99 Alternate Answer Key None SL1100 Table 2 9 Function Number List 2 Appearance Function Level 00 99 Service Code 852 Function Number Function Additional Data LED Indication 01 Trunk Key Trun...

Страница 359: ... DSS consoles DSS One Touch key 200 259 The DSS keys 061 114 of all DSS consoles No Setting SL1100 Conditions None Feature Cross Reference Direct Station Selection DSS Console ISSUE 3 01 SL1000 SL1100 Programming Manual 2 337 Program 30 ...

Страница 360: ...essing the ALT key on the DSS console Input Data Index 1 DSS Console Number 01 12 Index 2 Item No Item Input Data Default 01 DSS Console Alternate Answer Alternate DSS No 01 12 0 No setting 0 No Setting Conditions Related extension is assigned in Program 30 02 Alternate answer key ALT key is assigned at Program 30 03 Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 338 Program 30 DSS DLS Co...

Страница 361: ...1100 0 7 Lamp Pattern Data 2 12 Hotel Status Code 4 Hotel DSS SL1100 0 7 Lamp Pattern Data 3 13 Hotel Status Code 5 Hotel DSS SL1100 0 7 Lamp Pattern Data 5 14 Hotel Status Code 6 Hotel DSS SL1100 0 7 Lamp Pattern Data 3 15 Hotel Status Code 7 Hotel DSS SL1100 0 7 Lamp Pattern Data 6 16 Hotel Status Code 8 Hotel DSS SL1100 0 7 Lamp Pattern Data 4 17 Hotel Status Code 9 Hotel DSS SL1100 0 7 Lamp Pa...

Страница 362: ...1 1 1 0 1 1 1 1 0 011 pattern 4 1 0 1 0 1 0 0 0 0 0 100 pattern 5 1 0 0 0 0 0 0 0 0 0 101 pattern 6 1 0 1 0 0 0 0 0 0 0 110 pattern 7 1 1 1 1 1 1 0 1 0 1 111 200 400 600 800 1000 1200 1400 1600 1800 2000 m s LED Patterns for DSS Console SL1000 SL1000 SL1100 ISSUE 3 01 2 340 Program 30 DSS DLS Console Setup Program 30 ...

Страница 363: ...ttern 4 IR On 125m s Off 125m s On 125m s Off 625m s LED Pattern 5 IL On 875m s Off 125m s LED Pattern 6 IW On 625m s Off 125m s On 125m s Off 125m s LED Pattern 7 ON On Off On Off On Off On Off LED Patterns for DSS Console SL1100 Conditions None Feature Cross Reference Direct Station Selection DSS Console ISSUE 3 01 SL1000 SL1100 Programming Manual 2 341 Program 30 ...

Страница 364: ...acters J L j l 5 6 Enter characters M O m o 6 7 Enter characters P S p s 7 8 Enter characters T V t v 8 9 Enter characters W Z w z 9 0 Enter characters 0 ô õ ú å ä æ ö ü α ε θ В Enter characters π Σ σ Ω Accepts an entry only required if two letters on the same key are needed ex TOM Pressing again Space In system programming mode use the right arrow soft key instead to accept and or add a space Cle...

Страница 365: ...800 seconds Once the user initiates a Meet Me Conference or Voice Call Confer ence the system waits this time for the Paged party to join the call 90 seconds Conditions None Feature Cross Reference Paging External Paging Internal ISSUE 3 01 SL1000 SL1100 Programming Manual 2 343 Program 31 ...

Страница 366: ...l Paging Group Number 0 32 0 No setting Assign extensions to Internal Paging Groups i e Page Zones The system al lows up to 32 Internal Paging Groups An extension can be in only one Internal Pag ing Group All stations 0 02 Internal All Call Pag ing Receiving 0 Off 1 On Allow or prevent All Call Internal Paging for each extension If allowed extension can place and receive All Call Internal Paging a...

Страница 367: ...Enter characters A C a c 2 3 Enter characters D F d f 3 4 Enter characters G I g i 4 5 Enter characters J L j l 5 6 Enter characters M O m o 6 7 Enter characters P S p s 7 8 Enter characters T V t v 8 9 Enter characters W Z w z 9 0 Enter characters 0 ô õ ú å ä æ ö ü α ε θ В Enter characters π Σ σ Ω Accepts an entry only required if two letters on the same key are needed ex TOM Pressing again Space...

Страница 368: ...xtension to have normal 0 muted 1 or no 2 Internal Paging alert beeps before a Paging announcement 0 Default Item 01 Internal Paging Group Name Extension Paging Group Name 01 Group 1 02 Group 2 32 Group 32 Conditions None Feature Cross Reference Paging Internal SL1000 SL1100 ISSUE 3 01 2 346 Program 31 Paging Setup Program 31 ...

Страница 369: ...o simplify programming and troubleshooting always make the External Paging Zone Group the same number as the External Paging zone i e 1 1 2 2 etc Input Data External Speaker Number 1 3 Item No Item Input Data Default 01 Paging Group Number 0 3 0 No setting 1 3 Group number Speaker 1 Basic 1 Group 1 Speaker 2 Expan sion1 2 Group 2 Speaker 3 Expan sion2 3 Group 3 Conditions None Feature Cross Refere...

Страница 370: ...parate entry for each External Paging zone For UNA ringing make a separate entry for each Night Service mode Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Day Night Mode 1 8 External Speaker Number 1 3 Item No Item Input Data Default 01 Universal Night Answer Ring 0 No Ringing No 1 Ringing Yes 0 Conditions None Feature Cross Reference Night Service Paging External SL1000 SL1100 ISSUE ...

Страница 371: ...Paging an nouncement 2 02 Broadcast Splash Tone After Paging Paging End Time 0 No Tone None 1 Splash Tone 2 Chime Tone Use this option to enable or disable splash tone after Paging over an external zone If enabled the system broadcasts a splash tone at the end of an External Paging an nouncement 2 03 Speech Path 0 Both Way Duplex 1 One Way Simplex Determine if the external speaker will be used for...

Страница 372: ...ge they simultaneously broadcast into both the External and Internal Zone Use Program 31 04 01 to assign an External Paging Zone 1 3 to an External Page Group 0 3 Input Data External Paging Group Number 0 3 0 All External Paging Item No Item Input Data Default 01 Internal Paging Group Number 0 32 0 All Internal Paging 1 Conditions None Feature Cross Reference Paging External Paging Internal SL1000...

Страница 373: ...usic over the zone when it is idle Input Data External Speaker Number 1 3 Item No Item Input Data Description Default 01 BGM 0 BGM Prevented No 1 BGM allowed Yes Use this option to allow or prevent the Ex ternal Paging zone you select from broad casting Background Music when it is idle 0 Conditions None Feature Cross Reference Background Music Paging External ISSUE 3 01 SL1000 SL1100 Programming M...

Страница 374: ...and defines the splash tone for external paging Input Data External Speaker Number 01 03 Item No Item Input Data Default 01 External Speaker Name Up to 12 Characters External Speaker Num ber 01 Group 1 External Speaker Num ber 02 Group 2 External Speaker Num ber 03 Group 3 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 352 Program 31 Paging Setup Program 31 ...

Страница 375: ...e time specified in this program 30 seconds 02 Door Lock Cancel Time 0 64800 seconds When a user activates the door lock re lease relay this program specifies the amount of time the door strike remains open 10 seconds 03 Off Premise Call For ward by Door Box Disconnect Timer 0 64800 seconds Define the conversation period for an Off Premise Call Forward by Door Box call When this timer expires the ...

Страница 376: ...ed Door Phone when programming via WebPro and using a multiline terminal Input Data Door Box Number 1 8 SL1000 1 6 SL1100 Day Night Mode 1 8 Door Box Ring Group Number 01 32 Item No Item Input Data Default 01 Extension Number Maximum four digits SL1000 Maximum eight digits SL1100 Door Box Ringing Member 1 200 Other No Setting Conditions None Feature Cross Reference Door Box SL1000 SL1100 ISSUE 3 0...

Страница 377: ...escription Default 01 Chime Pattern 0 None 1 Door Box Ring 1 2 Door Box Ring 2 3 Door Box Ring 3 4 Door Box Ring 4 5 Door Box Ring 5 6 Door Box Ring 6 7 Door Box Ring 7 SL1000 8 Door Box Ring 8 SL1000 Door Box 1 1 Door Box 2 2 Door Box 3 3 Door Box 4 4 Door Box 5 5 Door Box 6 6 Door Box 7 1 SL1000 Door Box 8 1 SL1000 02 CODEC Transmit Gain Setup 1 63 15 5 dB 15 5 dB This program controls the gain ...

Страница 378: ...m No Item Input Data Default 01 Door Box Name Up to 12 characters This feature is available for IP Phone Only Digital Terminal will only show the default name ex DOOR 1 V1 5 Added SL1000 Door Box Name 1 DOOR 1 Door Box Name 2 DOOR 2 Door Box Name 3 DOOR 3 Door Box Name 4 DOOR 4 Door Box Name 5 DOOR 5 Door Box Name 6 DOOR 6 Door Box Name 7 DOOR 7 SL1000 Door Box Name 8 DOOR 8 SL1000 Conditions None...

Страница 379: ...0 Specify Extension Number Intercom 1 Use Conversion Table NTT Determine if the incoming Tie Line call should be directed as an inter com call or if it should follow the DID Translation Table in Program 22 11 0 22 11 04 E M Line Dial Tone 0 Disable No 1 Enable Yes Enter 1 if the Tie Line should send dial tone to the calling system after the call is set up Enter 0 if the Tie Line should not send di...

Страница 380: ...ice options are defined in Program 20 14 For each Tie line make a separate entry for each Night Service mode Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Day Night Mode 1 8 Item No Item Input Data Default Related Program 01 Class 1 15 1 20 14 Conditions Program 20 06 cannot be used to assign Class of Service to Tie lines Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 358 Pro...

Страница 381: ...runk Group Routing in Program 14 07 If the system has Automatic Route Selection ARS F Route dialing 9 accesses ARS Make a separate entry for each Tie Line for each Night Service Mode Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Day Night Mode 1 8 Item No Item Input Data Default 01 Route Table Number 00 25 0 No setting 1 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 S...

Страница 382: ...s 21 05 and 21 06 For each Tie Line you make a separate Toll Restriction Class entry for each Night Service mode Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Day Night Mode 1 8 Item No Item Input Data Default Related Program 01 Toll Restriction Class 1 15 1 21 05 14 01 08 Conditions Program 20 06 cannot be used to assign Toll Restriction to Tie Lines Feature Cross Reference None SL10...

Страница 383: ...rom an inbound trunk e g dialed from a Tie Line For each inbound trunk group enable or disable access to each CO trunk group Input Data Incoming Trunk Group Number 01 25 Trunk Group Number 01 25 Item No Item Input Data Default 01 Outgoing Trunk Group Number 0 Enable Y Tandem 1 Restricted N Tandem 0 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 361 Progr...

Страница 384: ...dividual extension users do not want to receive an incoming call they could delete all digits including the extension number Add Digit If a Tie Line network requires additional digits to reroute the call to a location the digits for the location can be added to the received digits Input Data Incoming Trunk Group Number 01 25 Item No Item Input Data Default 01 Delete Digit 0 255 255 delete all digi...

Страница 385: ... seconds 3 02 First Digit Pause E M Wink Start 0 64800 seconds 0 03 First Digit Pause LD Trunk 0 64800 seconds 3 04 LD Trunk Guard Time 0 64800 seconds 0 05 Trunk Answer Detect Timer for E M 0 64800 seconds 30 Conditions If Program 34 07 05 is left at default 30 the transferred call recalls to the station that performed the transfer when not answered Feature Cross Reference None ISSUE 3 01 SL1000 ...

Страница 386: ...tion data for E M Tie Lines This data should be defined if Tie Line Toll Restriction is enabled in Program 21 05 13 Input Data Class of Service 01 15 Table No 01 20 Item No Item Input Data Default Related Program 01 Dial Data Up to 10 Digits 0 9 No Setting 21 05 13 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 364 Program 34 Tie Line Setup Program 34 ...

Страница 387: ...s The character indi cates a delimiter If Program 34 01 02 is selected to 2 MF this Program works only as 4 ANI DNIS COS 01 0 COS 02 15 0 34 01 02 34 09 02 02 Delimiter Dial Code 1 9 0 This option defines the character Telco uses as a delimiter see en tries 1 5 in Item 1 above Valid entries are 0 9 and COS 01 COS 02 15 34 09 01 03 Route Setup of Receive Dial 0 Fixed Route Item 08 No Routing 1 Rout...

Страница 388: ...tup Start 0 100 900 End 0 99 999 Use this option to define which part of the ABB Table set up in Program 13 04 the system uses for ANI DNIS Caller ID look ups and ANI DNIS routing This is required if Items 4 and 5 above are 1 Caller ID on When you specify a starting and end ad dress the system uses the part of the table for look ups When you specify a starting address and length the system uses th...

Страница 389: ...ess Length 1 8 When Item 01 0 ANI DNIS re ceive format is the address use this option to specify the address length The choices are from 1 8 digits COS 01 7 COS 02 15 7 34 09 01 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 367 Program 34 ...

Страница 390: ...02 MFC Dialing Type 0 MFC Dialing not used 1 NEC Standard 2 Argentina 3 Brazil 4 Chile 5 Colombia 6 Mexico 7 Venezuela Use this option to specify the MFC Dialing Type The following table shows the avail able MFC Dialing Type choices By de fault this option is 0 MFC Dialing not used 0 03 MFC Group B 0 Disable 1 Enable Use this option to enable 1 or disable 0 the MFC Dialing Group B supervisory sig ...

Страница 391: ...Conditions After set Program 34 11 01 System needs to be re started Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 369 Program 34 ...

Страница 392: ...panish Specify the language in which the SMDR header should be printed 0 04 Omit Digits 0 24 0 Not applied The number of digits entered in this option does not print on the SMDR report For ex ample if the entry is 10 the first 10 digits a user dials do not appear on the SMDR re port 0 05 Minimum Digits 0 24 0 Not applied Outgoing calls must be at least this num ber of digits for inclusion in the S...

Страница 393: ...Feature Cross Reference Station Message Detail Recording ISSUE 3 01 SL1000 SL1100 Programming Manual 2 371 Program 35 ...

Страница 394: ...night every night 1 05 Summary Weekly 0 Not Displayed 1 Displayed Set this option to 1 to have the SMDR re port provides a weekly summary every Saturday at midnight 1 06 Summary Monthly 0 Not Displayed 1 Displayed Set this option to 1 to have the SMDR re port provides a monthly summary at mid night on the last day of the month 1 07 Toll Charge Cost 0 Not Displayed 1 Displayed Set this option to 1 ...

Страница 395: ...splay from the last digit Determine if the dialed number should dis play from the first digits or from the last digits This option is only available for out going calls 0 20 External Information CFW Mode 0 Transfer Information 1 Incoming Information Determine which information is displayed in the STATION area for a transferred call when the extension has Call Forward set with an Abbreviated Dial n...

Страница 396: ...rt for each trunk group For each Trunk Group select the SMDR port where the incoming SMDR information should be sent Input Data Trunk Group Number 01 25 Item No Item Input Data Default 01 SMDR Port No 1 2 1 Conditions None Feature Cross Reference Station Message Detail Recording Trunk Group Routing SL1000 SL1100 ISSUE 3 01 2 374 Program 35 SMDR Account Code Setup Program 35 ...

Страница 397: ...or each Department Group For each Department Group select the SMDR port where the outgoing SMDR information should be sent There are 32 available Department Groups Input Data Department Group Number 01 32 Item No Item Input Data Default 01 SMDR Port No 1 2 1 Conditions None Feature Cross Reference Station Message Detail Recording ISSUE 3 01 SL1000 SL1100 Programming Manual 2 375 Program 35 ...

Страница 398: ...ion with PRG 35 06 01 required Use this option to select the Account Code Mode 0 3 0 02 Forced Account Code Toll Call Setup 0 Account Codes for ALL calls 1 Account Codes for TOLL calls Use this option enable Account Codes for all calls or just toll calls for mode 2 or 3 in Item 01 above 0 03 Account Codes for In coming Calls 0 Disabled User can not enter an account code 1 Enabled User can enter an...

Страница 399: ...Feature Cross Reference Account Code Forced Verified Unverified ISSUE 3 01 SL1000 SL1100 Programming Manual 2 377 Program 35 ...

Страница 400: ...on Default 01 Verified Account Code 1 9 0 Wild card Up to 16 digits If PRG 35 05 01 is set to a 3 required and verified this is where the verified ac count code list is created in the system Up to 800 account codes with 1 16 digits can be entered Wild cards can be entered by using the symbol For example 234 means the user can enter 0234 9234 as valid ac count codes The digit cannot be used in the ...

Страница 401: ... 02 UK English 03 Australian English 04 French Canadian 05 Dutch 06 Mexican Spanish 07 Latin America Spanish 08 Italian 09 German 10 Madrid Spanish 11 Norwegian 12 Parisian French 13 Brazilian Portuguese 14 Japanese 15 Mandarin Chinese 16 Korean 17 Iberian Portuguese 18 Greek 19 Danish 20 Swedish 21 Thai 22 Mandarin Chinese Taiwan 23 Flemish 24 Turkish 25 Arabic 26 Russian V3 0 Added 2 Conditions ...

Страница 402: ...Greet ing enabled and all VRS ports are busy a DIL or DISA call to the ex tension waits this time for a VRS port to become free 0 05 Park and Page Repeat Timer VRS Msg Re send 0 64800 seconds If a Park and Page is not picked up during this time the Paging an nouncement repeats 0 06 Set VRS Mes sage for Private Call Refuse VRS Msg Private Call 0 No Message Played 1 100 VRS Mes sage 1 100 101 VRS Fi...

Страница 403: ...lay Flag that control the playback of the VRS announcements for on the for warded phone 1 40 10 01 11 Call Forward No tification An nouncement V2 0 Added 0 Do not play 1 Play Flag that control the playback of the VRS announcements for towards the incoming call 1 40 10 01 Conditions None Feature Cross Reference Voice Response System VRS ISSUE 3 01 SL1000 SL1100 Programming Manual 2 381 Program 40 ...

Страница 404: ...ach trunk When the extension user answers the incoming call the assigned VRS message is sent to the outside caller Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Day Night Mode 1 8 Item No Item Input Data Default 01 VRS Message Number 0 100 0 No Service 0 Conditions None Feature Cross Reference Voice Response System VRS SL1000 SL1100 ISSUE 3 01 2 382 Program 40 Voice Recording System P...

Страница 405: ... Calls You must make an entry for this program if you have selected 1 or 2 in Item 01 above 0 03 Wake Up Call No An swer 0 No Transfer 1 Transfer to the Oper ator 0 04 Setup Message Mode for Wake Up Call Ho tel Mode 0 Confirmation Tone 1 VAU Message 2 Time Stamp VAU Message 0 05 Wake Up Call Mes sage Assignment 0 100 0 No setting 0 06 Flexible Room Status V2 0 Added 0 Off 1 On When PRG42 01 06 is ...

Страница 406: ... Toll Restriction Class when it is checked in The system has 15 Toll Restriction Classes 1 15 The entry you make in this option affects the tele phone in all Night Service modes Refer to Programs 21 05 and 21 06 to set up the Toll Restriction dialing options When the extension is checked out it uses the Toll Restriction Class set in Program 21 04 1 03 Room Status Refer ence Only V2 0 Add ed Read O...

Страница 407: ...Feature Cross Reference Hotel Motel ISSUE 3 01 SL1000 SL1100 Programming Manual 2 385 Program 42 ...

Страница 408: ...xtension 0 Off 1 On Class 01 15 1 06 Room Status Change for Other Extension 0 Off 1 On Class 01 15 1 07 Restriction Class Changing for Other Extension 0 Off 1 On Class 01 15 1 08 Room to Room Call Restriction 0 Off 1 On Class 01 15 1 09 DND Setting for Own Extension 0 Off 1 On Class 01 15 1 10 Wake Up Call Setting for Own Extension 0 Off 1 On Class 01 15 1 11 Change Room Status for Own Extension 0...

Страница 409: ...ame on this staff phone V3 0 Added 0 Disable 1 Enable Enable guest name indication on staff ter minal Setting for staff terminal 1 Conditions None Feature Cross Reference Class of Service Hotel Motel ISSUE 3 01 SL1000 SL1100 Programming Manual 2 387 Program 42 ...

Страница 410: ...de with up to four digits SL1000 up to eight digits SL1100 such as an extension number or access code Input Data Department Extension Group Number 01 32 Received Dial 1 9 0 Item No Item Input Data Default 01 Hotel Mode One Digit Service Co des Destination Number Up to four digits SL1000 Up to eight digits SL1100 No Setting Conditions The one digit service codes you assign in this program wait unti...

Страница 411: ...eature Input Data Item No Item Input Data Description Default 01 Output Port Type 0 No Setting 3 LAN 0 03 Wake Up Call No An swer Data 0 Not Output 1 Output 0 04 Check Out Sheet 0 Not Output 1 Output 0 05 PMS Protocol type V2 0 Added 0 Normal 1 Fidelio Determines the PMS Protocol type 0 Conditions Room Status Reports can be output via LAN port Feature Cross Reference Hotel Motel ISSUE 3 01 SL1000 ...

Страница 412: ...seconds Defines the time that passes after any PMS message sent from the PBX that the PBX sends an AREYUTHERE message 10 06 AREYUTHERE LINET EST Send Count 0 20 times This is the retry count for un acknowl edged AREYUTHERE messages When this consecutive count of AREYU THERE messages is unacknowledged the PBX assumes the PMS link to be inopera tional off line 3 07 Check Out Auto Flexi ble Status Ch...

Страница 413: ...Conditions None Feature Cross Reference Hotel Motel ISSUE 3 01 SL1000 SL1100 Programming Manual 2 391 Program 42 ...

Страница 414: ... check in for a room PRG 42 02 02 This command translates the Toll Restriction level received from the hospitality application into a system Toll restriction Class Input Data Restriction Level 0 3 Item No Item Input Data Default 01 PMS Restriction Level Conversion Table 1 15 Level 0 10 Level 1 11 Level 2 12 Level 3 13 Conditions None Feature Cross Reference Hotel Motel SL1000 SL1100 ISSUE 3 01 2 3...

Страница 415: ...k Out Item No Item Input Data Default 01 Fedelio Room Status Number 0 Refer below 02 Text Message Data Maximum 32 characters Refer below Default No Room Status Fidelio Code alphanumeric 12345678901234567890123456789012 1 Check In 6 Check Out 5 2 Check In 2 Check Out 1 3 Check In 2 Check Out 1 4 Check In 4 Check Out 3 5 Check In 4 Check Out 3 6 Check In 4 Check Out 3 7 Check In 4 Check Out 3 8 Chec...

Страница 416: ...2345678901234567890123456789012 9 Check In 4 Check Out 3 0 Check In 6 Check Out 5 Check In 4 Check Out 3 Check In 4 Check Out 3 Conditions None Feature Cross Reference Hotel Motel SL1000 SL1100 ISSUE 3 01 2 394 Program 42 Hotel Setup Program 42 ...

Страница 417: ...pply to the system itself Input Data Room Status 1 2 3 4 5 6 7 8 9 0 Item No Item Input Data Default 01 Flexible Setup for Room Status 1 Room Clean Occupied 2 Maid Required 3 Maid in Room 4 Inspection Required 5 Maintenance Request 6 Out of order 7 Reserve 1 8 Reserve 2 9 Reserve 3 0 Room Clean Vacant Reserve 5 Reserve 6 1 None Conditions None Feature Cross Reference Hotel Motel ISSUE 3 01 SL1000 ...

Страница 418: ...0 If there is a match the pattern defined in that program is used If not the F Route pattern in PRG 44 09 and time setting in 44 08 are used 0 02 Dial Tone Simulation V2 0 Added 1 digit 0 9 cant be used When first dialed digit matches with the data set in this Program system send si mulated DT to calling party after receiving first digit Numbering plan for the dial needs to configure as F Route at...

Страница 419: ...lyze Table Option Service Type 1 Extension Number The number goes to an extension after deleting the front digit s Additional Data Assign the digit s to be deleted on top of the number for extension number us age At least one digit must be deleted Service Type 2 ARS F Route The number is controlled by ARS F Route table Additional Data If the ARS F Route Time Schedule is not used assign the ARS F R...

Страница 420: ...ting Refer to Program 44 05 Program 44 01 1 ARS F Route Select Table Number 0 100 0 No Setting Refer to Program 44 04 3 Dial Extension Analyze Table Num ber 0 4 0 No Setting Refer to Program 44 03 0 04 Dial Tone Simulation 0 Off 1 On If enabled this option sends dial tone to the calling party after the routing is deter mined This may be required if the central office at the destination does not se...

Страница 421: ...Extension Table Area Number 1 4 Dial Analysis Table Number 1 252 Dial Analysis Table Number 1 250 Item No Item Input Data Default 01 Dial Up to 36 digits Digits 1 9 0 Press Line Key 1 for wild character No Setting 02 ARS F Route Select Table Number 0 100 ARS F Route Table Number With Program 44 01 set to 0 Program 44 05 is checked With Program 44 01 set to 1 Program 44 04 is checked 0 Dial Analysi...

Страница 422: ...Conditions None Feature Cross Reference Automatic Route Selection ARS F Route SL1000 SL1100 ISSUE 3 01 2 400 Program 44 ARS F Route Setup Program 44 ...

Страница 423: ...an ARS F Route table number for each ARS F Route time mode There are eight time modes for ARS F Route Access Input Data ARS F Route Selection Number 001 100 ARS F Route Time Mode 1 8 Item No Item Input Data Default 01 ARS F Route Table Number 0 100 0 No Service 0 Conditions None Feature Cross Reference Automatic Route Selection ARS F Route ISSUE 3 01 SL1000 SL1100 Programming Manual 2 401 Program ...

Страница 424: ...ect whether or not a beep is heard if a lower priority trunk group is used to dial out 0 05 Gain Table Number for Internal Calls 0 100 0 No setting Select the gain table number to use for the internal call defined in Program 44 07 0 06 Gain Table Number for Tandem Connec tions 0 100 0 No setting Select the gain table number to use for the tandem call defined in Program 44 07 0 07 ARS Class of Serv...

Страница 425: ...Feature Cross Reference Automatic Route Selection ARS F Route ISSUE 3 01 SL1000 SL1100 Programming Manual 2 403 Program 44 ...

Страница 426: ...number The Additional Dial Table used is determined in Program 44 05 03 Input Data Additional Dial Table Number 001 100 Item No Item Input Data Default 01 Additional Dial Up to 36 digits Enter 1 9 0 Pause press LK 1 to enter a pause No Setting Conditions None Feature Cross Reference Automatic Route Selection ARS F Route SL1000 SL1100 ISSUE 3 01 2 404 Program 44 ARS F Route Setup Program 44 ...

Страница 427: ...activated The Tandem Gain Table follows the Incoming transmit and Incoming receive settings for incoming line and Outgoing transmit and Outgoing receive settings for the outgoing line For ARS F Route calls the CODEC gains defined in Programs 14 01 02 and 14 01 03 are not activated Input Data Gain Table Number 001 100 Item No Item Input Data Default 01 Incoming Transmit 1 63 15 5 dB 15 5 dB 32 0 dB...

Страница 428: ... Schedule Pattern Number 01 10 Item No Item Input Data 01 Time Number 01 20 Start Time 0000 2359 End Time 0000 2359 Mode 1 8 Default All Schedule Patterns 0 00 0 00 Mode 1 Example Pattern 1 0 00 0 00 8 00 18 00 22 00 M ode 3 M ode 1 M ode 2 M ode 3 Time Number 01 00 00 08 00 Mode 3 Time Number 02 08 00 18 00 Mode 1 Time Number 03 18 00 22 00 Mode 2 Time Number 04 22 00 00 00 Mode 3 Pattern 2 0 00 ...

Страница 429: ...Feature Cross Reference Automatic Route Selection ARS F Route ISSUE 3 01 SL1000 SL1100 Programming Manual 2 407 Program 44 ...

Страница 430: ...e pattern number is defined in Program 44 08 01 Input Data Day Number 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday Item No Item Input Data Default 01 Schedule Pattern Number 0 10 0 No Setting Sunday Saturday Pattern 1 Conditions None Feature Cross Reference Automatic Route Selection ARS F Route SL1000 SL1100 ISSUE 3 01 2 408 Program 44 ARS F Route Setup Program 44 ...

Страница 431: ...is schedule is used for setting special days such as national holidays The pattern number is defined in Program 44 08 01 Input Data Item No Item Input Data Default 01 Date 0101 1231 Schedule Pattern Number 0 10 0 No Setting Date 0101 1231 Pattern 0 Conditions None Feature Cross Reference Automatic Route Selection ARS F Route ISSUE 3 01 SL1000 SL1100 Programming Manual 2 409 Program 44 ...

Страница 432: ...tem has been modi fied so that extensions begin with the digit 1 e g 101 102 etc Also see the Flexible System Number ing feature 1 45 01 11 04 Park and Page 0 Off 1 On Enable disable the system ability to process the Voice Mail Park and Page commands You should normally enable this option 1 45 01 12 05 Message Wait 0 Off 1 On Enable disable the system ability to process the Voice Mail Message Wait...

Страница 433: ...d As signment Up to four digits Assign up to four digits in front of the station number sent to the SLT port when a call is forwarded No Setting 15 03 16 17 Reply Mailbox Number 0 No 1 Yes Whether or not to include the mail box number in the analog voice mail protocol 1 45 04 18 Trunk Number Mapping 2 3 Assign the digits of trunk number mapping 2 Conditions None Feature Cross Reference Voice Mail ...

Страница 434: ... Mail integration Input Data Item No Item Input Data Default 01 Send DTMF tone or 6KD message 0 Send DTMF tone to SLT VM port 1 Send 6KD message to Serial port 1 03 Send 51A Message 0 Off 1 On 1 05 Send 4PM message 0 Off 1 On 0 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 412 Program 45 Voice Mail Integration Program 45 ...

Страница 435: ...its No Setting 45 01 15 03 Transfer Message Up to four digits No Setting 45 01 15 04 Forward All Up to four digits No Setting 45 01 15 05 Forward Busy Up to four digits No Setting 45 01 15 06 Forward RNA Up to four digits No Setting 45 01 15 07 Remote Logon Up to four digits No Setting 45 01 15 08 Conversation Recording Up to four digits No Setting 45 01 15 09 Clear Down String Up to four digits N...

Страница 436: ...elated Program 01 Remote Log On Internal 0 Off 1 On 0 45 01 15 45 04 01 02 Direct Log On 0 Off 1 On 0 45 01 15 45 04 02 03 Transfer Message QVM 0 Off 1 On 0 45 01 15 45 04 03 04 Forward All 0 Off 1 On 0 45 01 15 45 04 04 05 Forward Busy 0 Off 1 On 0 45 01 15 45 04 05 06 Forward RNA 0 Off 1 On 0 45 01 15 45 04 06 07 Remote Log On 0 Off 1 On 0 45 01 15 45 04 07 08 Conversation Recording 0 Off 1 On 0...

Страница 437: ...e Length 1 4095 seconds Subs Msg Length Use this option to set the maximum length of recorded messages for Subscriber Mailbox users dialing RS to record and send a message Extension users leaving a message in a Subscriber Mailbox Outside Automated Attendant callers ac cessing a mailbox via a GOTO com mand and then dialing RS to record and send a message Subscriber Mailbox Greetings Announcement Me...

Страница 438: ...re InMail di als the Digital Pager Callback Number por tion of the Message Notification callout number for a digital pager Set this delay so the pager service has enough time to connect to the digital pager before sending the callback number Your pager service may be able to help you determine the best value for this op tion 0 99 seconds By default this option is 9 seconds When placing a digital p...

Страница 439: ...up without saying Hello This typi cally happens if someone unfamiliar with the notification answers the callout like the above example or if the call is picked up by an answering machine with insufficient outgoing message volume 30 13 Number of RNA rings V1 5 Changed 1 99 rings If a non pager callout rings the destination longer than this interval 1 99 rings In Mail marks the call as unanswered Ri...

Страница 440: ...9 33 37 41 45 49 53 57 61 65 69 73 77 79 81 85 89 93 97 101 105 0 18 Play PAD Control 1 63 15 5 dBm 15 5 dBm 32 19 Record PAD Control for Networking 1 63 15 5 dBm 15 5 dBm 32 Conditions When changing 47 01 01 or 47 01 02 a system reset is required for the new setting to take effect Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 418 Program 47 InMail Program 47 ...

Страница 441: ...nds to extension 200 Mailbox 1 64 1 Mailbox 65 0 02 Mailbox Number Up to four digits SL1000 Up to eight digits SL1100 Use this option to select the extension number associated with the mailbox you are programming Normally mailbox 1 should use Mailbox Number 200 mailbox 2 should use Mailbox Number 201 101 etc To make programming easier consider associating a mailbox number with a sta tion port For ...

Страница 442: ...ord If disabled the voice prompt and beep do not occur When you disable the Conversation Record beep the following voice prompts do not occur while InMail records the conversation Recording followed by a beep That mailbox is full if the mailbox message storage capacity is reached You have reached the recording limit if the recorded message is too long Provides an additional Conversation Re cord be...

Страница 443: ... Mailbox calls see Next Call Routing Mailbox below If enabled a caller who accesses the Sub scriber Mailbox to leave a message can di al any of the options in the Next Call Rout ing Mailbox Dial Action Table If disabled the caller can dial only 0 to use the Next Call Routing Mailbox 0 action 0 14 Next Call Routing Mailbox Call Routing Mailbox Number 1 3 digits 00 32 00 Undefined No entry Entered b...

Страница 444: ...here is no active notification desti nation 0 Table 2 10 47 02 16 Default Table Item Name Input Data 47 02 16 Voice Prompt Language 01 US English 02 UK English 03 Australian English 04 French Canadian 05 Dutch 06 Mexican Spanish 07 Latin America Spanish 08 Italian 09 German 10 Madrid Spanish 11 Norwegian 12 Parisian French 13 Brazilian Portuguese 14 Japanese 15 Mandarin Chinese 16 Korean 17 Iberia...

Страница 445: ... SL1100 No Setting entered by pressing Hold Mailbox Number The Group Mailbox Number is the same as the Department Group master pilot number Use this option to select the De partment Group master pilot number as sociated with the Group Mailbox you are programming No Setting 03 Mailbox Type 0 None 1 Subscriber 2 Routing Mailbox Type Use this option to set the Group Mailbox type There are three types...

Страница 446: ...ges InMail can play the oldest messages first first in first out or FIFO or the newest messag es first last in first out or LIFO 0 03 Auto Erase Save of Messages 0 Erase After the subscriber lis tens to the entire new message and hangs up InMail erases the mes sage 1 Save After the subscriber lis tens to the entire new message and hangs up InMail saves the mes sage Use this option to determine wha...

Страница 447: ...s option disabled 1 07 Auto Attendant Direct to Voice Mail 0 No Disabled 1 Yes Enabled Use this option to enable or disable Auto Attendant Direct to VM When a subscriber enables Auto Attendant Direct to VM an Automated Attendant caller routes directly to the mailbox hears the greeting and is asked to leave a message A subscriber can also enable Auto Attendant Direct to VM while recording their mai...

Страница 448: ... Call Routing Mailbox numbers are 01 16 13 Directory List Number 0 None 1 8 List Number All Specify the Directory List number to which the Group Mailbox belongs 0 14 Voice Prompt Lan guage Refer to Ta ble 2 11 47 06 14 De fault Table on page 2 427 2 15 Enable Paging 0 No 1 Yes 0 16 Paging Option 0 RNA 1 Immediate 0 17 Telephone User Inter face 0 Numeric interface 1 Mnemonic interface 2 Octel futur...

Страница 449: ...rica Spanish 08 Italian 09 German 10 Madrid Spanish 11 Norwegian 12 Parisian French 13 Brazilian Portuguese 14 Japanese 15 Mandarin Chinese 16 Korean 17 Iberian Portuguese 18 Greek 19 Danish 20 Swedish 21 Thai 22 Mandarin Chinese Taiwan 23 Flemish 24 Turkish 25 Arabic 26 Russian V3 0 Added Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 427 Program 47 ...

Страница 450: ...No Item Input Data Description Default 02 Routing Mailbox Type 0 None 1 Call Routing 2 Announcement 3 Directory 4 Distribution Mailbox Type Use this option to set the Routing Mailbox type Mailboxes 01 08 1 Call Routing Mailboxes 09 32 2 An nouncement 03 Prompt Language Refer to Ta ble 2 12 47 07 03 De fault Table on page 2 429 2 04 Telephone User Inter face 0 Numeric interface 1 Mnemonic interface...

Страница 451: ...rica Spanish 08 Italian 09 German 10 Madrid Spanish 11 Norwegian 12 Parisian French 13 Brazilian Portuguese 14 Japanese 15 Mandarin Chinese 16 Korean 17 Iberian Portuguese 18 Greek 19 Danish 20 Swedish 21 Thai 22 Mandarin Chinese Taiwan 23 Flemish 24 Turkish 25 Arabic 26 Russian V3 0 Added Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 429 Program 47 ...

Страница 452: ...es the Automated Attendant to immediately route callers to the Timeout destina tion programmed in the active Dial Action Table Dialing Timeout This option determines how long InMail waits for an Automated Attendant caller to dial before routing the call to the Timeout destination Be sure your Dial Action Tables have a Timeout action programmed If the caller waits too long to dial When the associat...

Страница 453: ...Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 431 Program 47 ...

Страница 454: ...the InMail System Guide 0 02 Repeat Count 0 10 Announcement repeats 1 10 times 0 No Repeats Enter the number of times you want the Announcement Mailbox message to repeat to callers After an Announcement Mailbox caller initially listens to the message it re peats the number of times specified in this option This option interacts with Next Call Routing Mailbox and Hang Up After when providing routin...

Страница 455: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 433 Program 47 ...

Страница 456: ... Assign ment Answer Table 1 16 V3 0 Changed Answer Table Use this option to assign an InMail Answer Table to each Direct Inward Line DIL the Automated Attendant should answer The Automated Attendant follows the routing specified by the selected Answer Table 1 02 Record PAD Control 1 63 15 5 dBm 15 5 dBm 32 03 Voice Prompt Lan guage Refer to Ta ble 2 13 47 10 03 De fault Table on page 2 435 2 04 Te...

Страница 457: ...rica Spanish 08 Italian 09 German 10 Madrid Spanish 11 Norwegian 12 Parisian French 13 Brazilian Portuguese 14 Japanese 15 Mandarin Chinese 16 Korean 17 Iberian Portuguese 18 Greek 19 Danish 20 Swedish 21 Thai 22 Mandarin Chinese Taiwan 23 Flemish 24 Turkish 25 Arabic 26 Russian V3 0 Added Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 435 Program 47 ...

Страница 458: ...Mail Answer Table Schedule Input Data Answer Table Number 1 16 V3 0 Changed Item No Item Input Data Description Default 01 Answer Schedule Override Sched ule Override Use this option to enable or disable Answer Schedule Override for the se lected Answer Table If enabled and you make an entry for Override Mail box below the active Answer Table routes calls to the Override Mailbox 0 No Disabled 1 Ye...

Страница 459: ...28 refer to 47 02 In Mail Station Mailbox Options on page 2 419 SL1000 Category 1 Mailbox No should be 1 120 refer to 47 02 In Mail Station Mailbox Options on page 2 419 SL1100 Category 2 Mailbox No should be 1 32 refer to 47 03 In Mail Group Mailbox Options on page 2 423 Category 3 Mailbox No should be 1 32 refer to 47 07 In Mail Routing Mailbox Options on page 2 428 0 Override Mailbox Number Ove...

Страница 460: ...ptions on page 2 419 SL1100 Category 2 Mailbox No should be 1 32 refer to 47 03 In Mail Group Mailbox Options on page 2 423 Category 3 Mailbox No should be 1 32 refer to 47 07 In Mail Routing Mailbox Options on page 2 428 Answer Ta ble 1 3 Answer Ta ble 2 8 0 Default Mailbox Number Default MB Num Use this option to set the Answer Ta ble Default Mailbox number InMail uses the Default Mailbox when a...

Страница 461: ... Answer Schedules to set up the InMail Automated Attendant Answer Schedules There are eight Answer Tables with up to 10 Answer Schedules in each Answer Table Input Data Answer Table Number 1 16 V3 0 Changed Schedule Entry Number 1 10 ISSUE 3 01 SL1000 SL1100 Programming Manual 2 439 Program 47 ...

Страница 462: ...g or Announce ment Mailbox used to answer calls 2 Range of Days A Type 2 Answer Schedule runs for a range of days For this type of schedule you select The day of the week the schedule should start The day of the week the schedule should stop The time on the start day the schedule should start The time on the stop day the schedule should stop The Call Routing or Announce ment Mailbox used to answer...

Страница 463: ...n to set the num ber of the Answering Mailbox the Automated Attendant uses when the selected schedule is in effect This mailbox is de fined in 47 12 02 Answering Mailbox Category Up to 3 digits using 0 9 Answer Table 1 Schedule 1 1 All Other Answer Schedules No set ting Category 0 Skip Mailbox No set ting Category 1 Mailbox No should be 1 128 refer to 47 02 InMail Station Mailbox Options on page 2...

Страница 464: ...edule Start Time and 47 12 08 Schedule End Time HHMM 24 hour clock For example 0130 1 30 AM 1700 5 00 PM 0000 Undefined Answer Table 1 Schedule 1 0830 All other schedules are 0000 08 Schedule End Time Entryxx End Time Use this option to specify the time the Answer Schedule should end It applies to Day of the Week Type 1 Range of Days Type 2 and Date Type 3 schedules To make a schedule run continuo...

Страница 465: ...d with a Call Routing Mailbox which is in turn associated with an Answer Table When an Answer Table is active its associated Call Routing Mailbox selects the Dial Action Table which provides dialing options to callers The illustration below shows how this works in a default InMail system There are 32 V3 0 or higher Dial Action Tables Input Data Dial Action Table Number 01 32 V3 0 Changed Key Numbe...

Страница 466: ...umber Ignore Digits Entry I Entered by pressing LK3 Use the I option to represent any digit dialed by the Auto mated Attendant caller that PZ VM21 InMail ignores for routing An example of this is REC action assigned to the key in Dial Action Table 1 by default The Action is REC2 and the Number is IXXX This means that a caller can dial any mailbox number to leave a Quick Message in that mailbox InM...

Страница 467: ... is set 0 or 6 skip Data setting XXX change as it fit The Data data needs to follow these rules below 0 UND none 1 TRF dial data any X I N or P 2 UTRF dial data any X I N or P 3 REC1 mailbox number subscriber or group 4 REC2 mailbox number subscriber or group 5 LOGON mailbox number subscriber or group 6 HANGUP none 7 GOTO routing mailbox number index 1 32 Otherwise it will not be routed properly C...

Страница 468: ...ox Number 01 32 Item No Item Input Data Default 01 Minimum Number of Letters Re quired 1 3 1 02 Directory List Number to Use 1 8 1 03 Name Match 0 First 1 Last 0 04 Transfer Option 0 TRF 1 UTRF 0 05 Screened Transfer Timeout 0 255 15 06 Time Limit for Dialing Commands 0 99 5 07 Fax Detection 0 Disable 1 Enable 0 08 Next Call Routing Mailbox 0 32 0 09 Fax Extension Up to eight digits No Setting Con...

Страница 469: ...ailbox Category 1 Mailbox No should be 1 128 refer to 47 02 InMail Station Mailbox Options on page 2 419 SL1000 Category 1 Mailbox No should be 1 120 refer to 47 02 InMail Station Mailbox Options on page 2 419 SL1100 Category 2 Mailbox No should be 1 32 refer to 47 03 InMail Group Mailbox Options on page 2 423 0 Distribution Mailbox Number Up to 3 digits Category 1 Mailbox No should be 1 128 refer...

Страница 470: ... Name Up to 48 characters No Setting 03 SMTP Port 0 65535 25 04 Encryption 0 No 1 Yes 0 05 Authentication 0 No 1 Yes 2 POP3 0 06 User Name Up to 48 characters No Setting 07 Password Up to 48 characters No Setting 08 E mail Address Up to 48 characters No Setting 09 Reply to Address Up to 48 characters No Setting Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 448 Program 47 ...

Страница 471: ...on Input Data Item No Item Input Data Default 01 Server Name Up to 48 characters No Setting 02 POP3 Port 0 65535 110 03 Encryption 0 No 1 Yes 0 04 User Name Up to 48 characters No Setting 05 Password Up to 48 characters No Setting Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 449 Program 47 ...

Страница 472: ...1 05 Notification Number Up to 16 digits No Setting 06 Notification Busy Attempts 1 99 attempts 5 07 Notification RNA Attempts 1 99 attempts 5 08 Notification Security 0 Off 1 On 1 09 Notification Day of week Sunday V1 5 Added 0 Disabled 1 Enabled 1 10 Notification Day of week Monday V1 5 Added 0 Disabled 1 Enabled 1 11 Notification Day of week Tuesday V1 5 Added 0 Disabled 1 Enabled 1 12 Notifica...

Страница 473: ...Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 451 Program 47 ...

Страница 474: ...M 23 11 00 PM 00 04 Find Me Follow Me Number Up to 16 digits No Setting 05 Find Me Follow Me Day of week Sunday V1 5 Added 0 Disabled 1 Enabled 1 06 Find Me Follow Me Day of week Monday V1 5 Added 0 Disabled 1 Enabled 1 07 Find Me Follow Me Day of week Tuesday V1 5 Added 0 Disabled 1 Enabled 1 08 Find Me Follow Me Day of week Wednesday V1 5 Added 0 Disabled 1 Enabled 1 09 Find Me Follow Me Day of ...

Страница 475: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 453 Program 47 ...

Страница 476: ...n Number Up to 16 digits No Setting 06 Notification Busy Attempts 1 99 attempts 5 07 Notification RNA Attempts 1 99 attempts 5 08 Notification Security 0 Off 1 On 1 09 Notification Day of week Sunday V1 5 Added 0 Disabled 1 Enabled 1 10 Notification Day of week Monday V1 5 Added 0 Disabled 1 Enabled 1 11 Notification Day of week Tuesday V1 5 Added 0 Disabled 1 Enabled 1 12 Notification Day of week...

Страница 477: ...Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 455 Program 47 ...

Страница 478: ...low Me Number Up to 16 digits No Setting 05 Find Me Follow Me Day of week Sunday V1 5 Added 0 Disabled 1 Enabled 1 06 Find Me Follow Me Day of week Monday V1 5 Added 0 Disabled 1 Enabled 1 07 Find Me Follow Me Day of week Tuesday V1 5 Added 0 Disabled 1 Enabled 1 08 Find Me Follow Me Day of week Wednesday V1 5 Added 0 Disabled 1 Enabled 1 09 Find Me Follow Me Day of week Thursday V1 5 Added 0 Disa...

Страница 479: ... 0 Endless Refer below Unit Number 1 8 Item No Item Input Data Default 02 Basic Tone Number 0 33 0 No Tone 33 Default Time Slot Refer below 03 Duration Count 0 255 0 100 25500 ms Refer below 04 Gain Level dB 0 63 15 5 15 5 Refer below Table 2 14 Basic Tones Basic Tone No Frequency Hz Level dB 01 420 13 02 520 13 03 580 13 04 660 13 05 700 13 06 800 13 07 880 13 08 1050 13 09 430 13 10 440 480 13 1...

Страница 480: ...ter Dial Tone Special Dial Tone 0 1 24 10 35 1 5 dB 4 Internal Recall Dial Tone Transfer Dial Tone 0 1 24 10 35 1 5 dB 5 Trunk Dial Tone 0 4 21 0 21 0 6 10 2 2 45 0 dB 45 0 dB 45 0 dB 45 0 dB 6 Internal Busy Tone Busy Tone 0 2 1 0 5 5 42 5 dB 42 5 dB 7 DND Busy Tone 0 2 1 0 2 2 42 5 dB 42 5 dB 8 B busy Tone 0 2 1 0 5 5 42 5 dB 42 5 dB 9 Internal Reorder Tone Congestion Tone 0 2 1 0 2 2 42 5 dB 42 ...

Страница 481: ... dB 26 3 dB 38 3 dB 26 3 dB 14 9 dB 32 0 dB 20 Doorphone chime 2 3 6 7 7 5 5 5 0 2 2 3 4 6 5 38 3 dB 26 3 dB 38 3 dB 26 3 dB 14 9 dB 32 0 dB 21 Doorphone chime 3 3 6 8 8 6 6 6 0 2 2 3 4 6 5 38 3 dB 26 3 dB 38 3 dB 26 3 dB 14 9 dB 32 0 dB 22 Doorphone chime 4 3 6 4 4 2 2 2 0 1 1 2 2 3 2 38 3 dB 26 3 dB 38 3 dB 26 3 dB 14 9 dB 32 0 dB 23 Doorphone chime 5 3 6 7 7 5 5 5 0 1 1 2 2 3 2 38 3 dB 26 3 dB ...

Страница 482: ...2 2 20 35 1 5 dB 35 1 5 dB 35 1 5 dB 35 1 5 dB 40 Internal Call Waiting Tone Transfer Call Waiting Tone 1 2 22 0 1 1 32 0 dB 32 0 dB 41 Intrusion tone 1 2 22 0 8 8 32 0 dB 32 0 dB 42 Conference tone 1 2 22 0 8 8 32 0 dB 32 0 dB 43 Intrusion tone 2 0 0 0 0 32 0 dB 44 External Dial Tone DUD DISA Dial Tone 0 4 21 0 21 0 6 10 2 2 45 3 dB 45 3 dB 45 3 dB 45 3 dB 45 External Ring Back Tone Ring Tone DDI...

Страница 483: ...B 26 3 dB 32 0 dB 26 3 dB 32 0 dB 26 3 dB 59 Ending Chime tone 1 8 20 20 19 19 18 18 17 17 2 2 2 2 2 2 6 4 32 0 dB 26 3 dB 32 0 dB 26 3 dB 32 0 dB 26 3 dB 32 0 dB 26 3 dB 60 Splash tone 1 Mute 0 2 0 1 1 1 42 5 dB 42 5 dB 61 Splash tone 2 Mute 1 2 0 1 1 1 42 5 dB 42 5 dB 62 Splash tone 3 Mute 3 2 0 1 1 1 42 5 dB 42 5 dB 63 EXT SPK Ring back Tone 0 2 24 0 10 40 35 1 5 dB 35 1 5 dB 64 Special Hold To...

Страница 484: ...ake separate entries for duration and pause It is also possible to adjust the level of both high and low frequency tone Input Data Item No Item Input Data Default 01 Duration 1 255 5 100 ms 02 Pause 1 255 5 100 ms 03 Tone Level Low dB 1 97 45 0 0 3 73 9 dB 04 Tone Level High 1 97 45 0 0 3 77 7 dB Duration Pause Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 462 Program 80 ...

Страница 485: ...ed Item No Item Input Data Description Default 01 Detect Level 0 0 dBm 25 dBm 1 5 dBm 30 dBm 2 10 dBm 35 dBm 3 15 dBm 40 dBm 4 20 dBm 45 dBm 5 25 dBm 50 dBm 6 30 dBm 55 dBm Used to select the systems DTMF tone de tection levels Refer below 02 Start Delay Time 0 255 0 25 ms 64 ms Refer below 03 Min Detect Level 0 15 DTMF Tone 0 10 dBm 0 to 25 dBm 15 DTMF Tone 1 15 dBm 0 to 30 dBm 15 DTMF Tone 2 20 ...

Страница 486: ... ms 3825 ms Refer below 09 Area Type 0 Other 1 Aust Refer below Default Item No Item Type 1 Type 2 Type 3 Type 4 Type 5 01 Detect Level 0 0 0 0 0 02 Start delay time 0 0 0 0 0 03 Min detect level 10 20 dBm 15 25 dBm 10 20 dBm 10 20 dBm 10 20 dBm 04 Max detect level 2 2 dBm 2 2 dBm 2 2 dBm 2 2 dBm 2 2 dBm 05 Forward twist level 5 6 dBm 5 6 dBm 5 6 dBm 5 6 dBm 5 6 dBm 06 Backward twist level 0 1 dBm...

Страница 487: ...o Item Input Data Default 01 Detection Level 0 0 dBm 25 dBm 1 5 dBm 30 dBm 2 10 dBm 35 dBm 3 15 dBm 40 dBm 4 20 dBm 45 dBm 5 25 dBm 50 dBm 6 30 dBm 55 dBm Refer below 02 Min Detection Level 0 15 0 10 dBm 0 25 dBm 15 1 15 dBm 0 30 dBm 15 2 20 dBm 0 35 dBm 15 3 25 dBm 0 40 dBm 15 4 30 dBm 0 45 dBm 15 5 35 dBm 0 50 dBm 15 6 40 dBm 0 55 dBm 15 Refer below 03 S N Ratio 0 4 0 dB 20 dB Refer below 04 No ...

Страница 488: ... Level 0 25 dBm 0 25 dBm 0 25 dBm 0 0 2 Min detect level 15 25 dBm 15 25 dBm 15 25 dBm 0 0 3 S N ratio 4 20 dB 4 20 dB 4 20 dB 0 0 4 No tone time 132 3990 ms 132 3990 ms 132 3990 ms 0 0 5 Pulse Count 1 1 1 0 0 6 ON min time 63 1920 ms 12 390 ms 25 780 ms 0 0 7 ON max time 0 20 630 ms 40 1230 ms 0 0 8 OFF min time 1 60 ms 12 390 ms 52 1590 ms 0 0 9 OFF max time 1 60 ms 20 630 ms 80 2430 ms 0 0 12 F...

Страница 489: ...define the date format when printing out the SMDR alarm report and system information report Input Data Item No Item Input Data Default 01 Date Format 0 American Format Month Day Year 1 Japanese Format Year Month Day 2 European Format Day Month Year 2 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 467 Program 80 ...

Страница 490: ...Ω or complex in COIU PKG SL1000 Use Program 80 06 Reference Impedance Setup to define the change of Reference Impedance 600 Ω or complex in SLIU PKG and COIU PKG SL1100 Input Data Item No Item Input Data Default 01 Reference Impedance Setup 0 600 Ω 1 Complex 1 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 468 Program 80 Basic Hardware Setup for System Program 80 ...

Страница 491: ... 04 12 and Program 80 04 13 Input Data Frequency Table Number 1 8 Item No Item Input Data Default 01 Frequency 0 10 255 100 2550 Hz 0 Not used Frequency Table No 1 40 400 Hz Frequency Table No 2 0 Frequency Table No 3 0 Frequency Table No 4 0 Frequency Table No 5 0 Frequency Table No 6 0 Frequency Table No 7 0 Frequency Table No 8 0 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL...

Страница 492: ...all trunk line calls system wide And also it is possible to adjust the level of tone Input Data Item No Item Input Data Default 01 Duration On time 1 255 20 ms 5100 ms 5 100 ms 02 Pause Off time 1 255 20 ms 5100 ms 5 100 ms 03 Tone Level 1 97 45 dB 3 dB 77 7 dB Duration Pause Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 470 Program 80 Basic Hardware Setup for System Prog...

Страница 493: ...equency 1 2 Table on page 2 471 Refer below 02 Frequency 2 00 No setting 01 15 Refer to Table 2 15 Frequency 1 2 Table on page 2 471 Refer below 03 Ring Cycle 00 No setting 01 14 Refer to Table 2 16 Ring Cycle Table on page 2 472 Refer below When a single tone is sent Frequency 1 2 is set to the same value Table 2 15 Frequency 1 2 Table Data Frequency Hz 01 392 02 440 03 494 04 523 05 587 06 659 0...

Страница 494: ...n 250 Off 250 On Off 09 325 On Off 10 325 On 325 Off 325 On Off 11 325 On 325 Off 325 On 325 Off 325 On Off 12 500 On Off 13 500 On 500 Off 500 On Off 14 1000 On Off Table 2 17 Default Table Short Ring No Short Tone Name Frequency 1 Frequency 2 Ring Cycle 1 Confirmation Tone 8 8 1 2 Error Tone 8 8 14 3 Alarm Tone for long conversation call 4 4 14 4 Not defined 0 0 0 32 Not defined 0 0 0 Conditions...

Страница 495: ... 0 10 dBm 0 25 dBm 15 detect level 1 15 dBm 0 30 dBm 15 detect level 2 20 dBm 0 35 dBm 15 detect level 3 25 dBm 0 40 dBm 15 detect level 4 30 dBm 0 45 dBm 15 detect level 5 35 dBm 0 50 dBm 15 detect level 6 40 dBm 0 55 dBm 15 Refer below 04 Max detect level 0 15 detect level 0 0 dBm 0 15 dBm 15 detect level 1 5 dBm 0 20 dBm 15 detect level 2 10 dBm 0 25 dBm 15 detect level 3 15 dBm 0 30 dBm 15 det...

Страница 496: ...ax detect level 0 0 dBm 0 0 dBm 0 0 dBm 0 0 dBm 0 0 dBm 05 Twist level 9 10 dBm 9 10 dBm 9 10 dBm 9 10 dBm 9 10 dBm 06 S N ratio 2 0 dBm 2 0 dBm 2 0 dBm 2 0 dBm 2 0 dBm 07 ON detect time 1 30 ms 1 30 ms 1 30 ms 1 30 ms 1 30 ms 08 OFF detect time 1 30 ms 1 30 ms 1 30 ms 1 30 ms 1 30 ms Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 474 Program 80 Basic Hardware Setup for Sy...

Страница 497: ...ction of DSP Input Data Item No Item Input Data Default 01 Type 0 NTT 1 Other 2 Korea 1 02 Level Mark 0 32766 50 03 Level Space 0 32766 50 04 Bit Sampling Type 0 Other 1 Malaysia 0 05 1st Bit Offset 0 32766 10 06 Minimum Seizure Count 0 32766 10 07 Guard Time when Mark 0 32766 1 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 475 Program 80 ...

Страница 498: ...100 ms 07 Double Ringing Detection Maxi mum Off Time 0 255 0 10 2550 ms 40 400 ms 08 Ringing Signal not Detection Mini mum 1 255 10 2550 ms 70 700 ms 09 Time Ringing Signal Stop Detec tion Time 1 255 100 25500 ms 50 5000 ms 10 Continuous Ringing Minimum Time 0 255 0 10 2550 ms 30 300 ms 11 Continuous Ringing Maximum Time 0 255 0 10 2550 ms 70 700 ms 14 Hook Flash 1 Time 1 255 10 2550 ms 80 800 ms ...

Страница 499: ...Time 10pps 1 255 5 1275 ms 13 65 ms 28 Dial Pulse Make Time 10pps 1 255 5 1275 ms 7 35 ms 29 DP Inter digit Time 10pps 1 255 10 2550 ms 61 610 ms 36 Long Ringing Detection Minimum Time 1 255 100 25500 ms 24 2400 ms Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 477 Program 81 ...

Страница 500: ... to define the various basic data for layer 1 of ISDN BRI Input Data Item No Item Input Data Default 01 Wait time for Physical Activation Timer 3 1 255 200 51000 ms 100 20 sec 02 Detection time for Physical Deacti vation 1 255 200 51000 ms 5 1 sec Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 478 Program 81 Basic Hardware Setup for Trunk Program 81 ...

Страница 501: ... in 1 100ths of a second between retransmissions of the TEI Identity check messages 10 1 sec 03 Timer T202 1 255 100 25500 ms Specify the minimum time in 1 100ths of a second between retransmissions of the TEI Identity check messages 20 2 sec 04 Timer T203 1 255 100 25500 ms Specify the maximum time in 1 100ths of a second allowed without exchanging frames 250 25 sec 05 N200 1 255 Specify the retr...

Страница 502: ...of the timer to be started when the SETUP ACK is received Timer is also re started when INFO is received 30 05 T305 1 254 seconds Specifies the timer value in 1 100ths of a second of the timer to be started when DISC without progress No 8 is sent 30 06 T306 0 254 seconds Specifies the timer value in 1 100ths of a second of the timer to be started when DISC with progress indicator No 8 is sent This...

Страница 503: ...he timer value in 1 100ths of a second of the timer to be started when RE START is received 60 16 T318 1 254 seconds Specifies the timer value in 1 100ths of a second of the timer to be started when RES is sent This timer is valid for user side use only 4 17 T319 1 254 seconds Specifies the timer value in 1 100ths of a second of the timer to be started when SUSPEND is sent This timer is valid for ...

Страница 504: ...alog trunk port Input Data Trunk Port Number 001 126 SL1000 001 096 SL1100 Item No Item Input Data Default 01 CODEC Filter Type 0 Type 0 1 Type 1 2 Type 2 3 Type 3 4 Type 4 5 Type 5 6 Type 6 7 Type 7 8 Type 8 9 Type 9 10 Type 10 11 Type 11 12 Type 12 13 Type 13 14 Type 14 15 Type 15 2 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 482 Program 81 Basic Hardware Setup for Tr...

Страница 505: ...8 Clear Signal Detection Time DID 1 255 100 ms 25500 ms 6 600 ms 09 Answer Signal Detection Time E M 1 255 100 ms 25500 ms 6 600 ms 10 Clear Signal Detection Time OPX 1 255 100 ms 25500 ms 6 600 ms 11 Ringing Signal Detection Time Loop 1 250 8 ms 2000 ms 10 80 ms 12 Ringing Signal Detection Time Ground 1 250 8 ms 2000 ms 10 80 ms 13 Ringing Signal Detection Time DID 1 250 8 ms 2000 ms 10 80 ms 14 ...

Страница 506: ...ID 1 250 8 ms 2000 ms 25 200 ms 37 Incoming Wink Send Time DID 1 255 100 ms 25500 ms 3 300 ms 38 Wink Send Duration Time E M 1 250 8 ms 2000 ms 25 200 ms 39 Delay Send Duration Time E M 1 250 8 ms 2000 ms 25 200 ms 40 Incoming Wink Send Time E M 1 255 100 ms 25500 ms 3 300 ms 41 Seizure WINK DELAY Receive Max Time DID 1 255 100 ms 25500 ms 48 4800 ms 42 Receive Wink Duration Min Time DID 1 250 8 m...

Страница 507: ...s 66 Single Between Ringing Send Time OPX 1 255 100 ms 25500 ms 9 900 ms 67 Guard Time 1 LOOP 1 255 100 ms 25500 ms 9 900 ms 68 Guard Time 1 GROUND 1 255 100 ms 25500 ms 9 900 ms 69 Guard Time 1 DID 1 255 100 ms 25500 ms 9 900 ms 70 Guard Time 1 E M 1 255 100 ms 25500 ms 9 900 ms 71 Guard Time 1 OPX 1 255 100 ms 25500 ms 9 900 ms 72 Guard Time 2 ALL 1 250 4 ms 1000 ms 3 12 ms 73 Dial Sending Compl...

Страница 508: ...255 194 11 B1 Filter Setup 11 0 255 219 12 B1 Filter Setup 12 0 255 45 13 B1 Filter Setup 13 0 255 178 14 B1 Filter Setup 14 0 255 208 15 B2 Filter Setup 1 0 255 178 16 B2 Filter Setup 2 0 255 208 17 AISN and Analog Gains 0 255 17 18 Z Filter Coefficients 1 0 255 250 19 Z Filter Coefficients 2 0 255 173 20 Z Filter Coefficients 3 0 255 50 21 Z Filter Coefficients 4 0 255 165 22 Z Filter Coefficien...

Страница 509: ...nts 13 0 255 43 46 R Filter Coefficients 14 0 255 37 47 X Filter Coefficients 1 0 255 202 48 X Filter Coefficients 2 0 255 48 49 X Filter Coefficients 3 0 255 37 50 X Filter Coefficients 4 0 255 187 51 X Filter Coefficients 5 0 255 170 52 X Filter Coefficients 6 0 255 189 53 X Filter Coefficients 7 0 255 162 54 X Filter Coefficients 8 0 255 163 55 X Filter Coefficients 9 0 255 165 56 X Filter Coef...

Страница 510: ...ve DP Make min Time 1 255 4 ms 1020 ms 3 12 ms 21 Receive DP Make max Time 1 255 4 ms 1020 ms 19 76 ms 22 Receive DP Break min Time 1 255 4 ms 1020 ms 5 20 ms 23 Receive DP Break max Time 1 255 4 ms 1020 ms 26 104 ms 24 Transmit Answer duration Time 1 255 8 ms 2040 ms 38 304 ms 25 Transmit Double Answer duration Time 1 255 64 ms 16320 ms 32 2048 ms 26 Receive Answer min Time 1 255 8 ms 2040 ms 25 ...

Страница 511: ... 63 1008 ms 42 Transmit Seizure Signal Time 1 255 8 ms 2040 ms 100 800 ms 43 Group A Response Time 1 32 1 sec 32 sec 12 12 sec 44 Group A Tone Complete Time 1 32 1 sec 32 sec 12 12 sec 45 Group B Response Time 1 32 1 sec 32 sec 12 12 sec 46 Group B Tone Complete Time 1 32 1 sec 32 sec 12 12 sec 47 Group C Response Time 1 32 1 sec 32 sec 12 12 sec 48 Group C Tone Complete Time 1 32 1 sec 32 sec 12 ...

Страница 512: ...d in Items 1 and 2 see below In this program you assign the two Frequency Numbers and Modulation for each Type for each of the four Ranges The chart below shows the default Frequency Numbers for each Type in each Range Input Data Incoming Ringing Tone Number 1 Pattern 1 Trunk Incoming 2 Pattern 2 Trunk Incoming 3 Pattern 3 Trunk Incoming 4 Pattern 4 Trunk Incoming 5 Intercom Incoming Pattern 6 Ala...

Страница 513: ...5 Intercom Incoming Pat tern High Mid Low 1100 Hz 660 Hz 520 Hz 1400 Hz 760 Hz 660 Hz 8 Hz Modulation 8 Hz Modulation 8 Hz Modulation Pattern 6 Alarm Sensor Pattern High Mid Low 760 Hz 760 Hz 760 Hz 760 Hz 760 Hz 760 Hz No Modulation No Modulation No Modulation Pattern 7 Trunk Incoming V3 0 Added High Middle Low 1400Hz 760Hz 660Hz 540Hz 540Hz 540Hz 16Hz Modulation 16Hz Modulation 16Hz Modulation P...

Страница 514: ... Callback Camp On Callback Follow me Setup Terminal Monitor Terminal been Setup Call Forward Terminal been Set up Message Waiting Terminal been set up 0 02 LED02 0 7 Other Terminal that been Hold Normal Hold Follow me Terminal been Setup Transfer Setup Terminal 1 03 LED03 0 7 Own Hold Message Waiting Terminal that has been Transferred 3 04 LED04 0 7 CO Line Key CO Callback key 0 05 LED05 0 7 Own u...

Страница 515: ...1 1 1 1 0 1 1 1 1 0 011 pattern 4 1 0 1 0 1 0 0 0 0 0 100 pattern 5 1 0 0 0 0 0 0 0 0 0 101 pattern 6 1 0 1 0 0 0 0 0 0 0 110 pattern 7 1 1 1 1 1 1 0 1 0 1 111 200 400 600 800 1000 1200 1400 1600 1800 2000 m s Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 493 Program 82 ...

Страница 516: ... Make Time 1 255 5 ms 1275 ms 20 100 ms 07 Minimum Hook Flash Time 1 255 5 ms 1275 ms 108 540 ms 08 Maximum Hook Flash Time 1 255 5 ms 1275 ms 132 660 ms 09 Minimum Ground Flash Time 1 255 5 ms 1275 ms 21 105 ms 10 Minimum Off Hook Time 1 255 5 ms 1275 ms 21 105 ms 11 No Detection Time after Off Hook 1 255 5 ms 1275 ms 60 300 ms 12 No Detection Time after Pulse Dial Detection 1 255 5 ms 1275 ms 70...

Страница 517: ... the Layer 2 of ISDN BRI PRI S Point Input Data Item No Item Input Data Default 01 Timer T200 1 255 100 25500 ms 10 1 sec 02 Timer T201 1 255 100 25500 ms 10 1 sec 03 Timer T202 1 255 100 25500 ms 20 2 sec 04 Timer T203 1 255 100 25500 ms 100 10 sec 05 N200 1 255 3 06 N201 1 65535 Byte 260 07 N202 1 255 3 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 49...

Страница 518: ...c 03 T303 1 254 sec 4 sec 04 T304 0 254 sec 20 sec 05 T305 1 254 sec 30 sec 06 T306 0 254 sec 30 sec 07 T307 1 254 sec 180 sec 08 T308 1 254 sec 4 sec 09 T309 1 254 sec 90 sec 10 T310 0 180 sec 30 sec 11 T312 1 254 sec 6 sec 12 T313 1 254 sec 4 sec 13 T314 1 254 sec 4 sec 14 T316 T317 1 254 sec 120 sec 15 T317 1 T316 1 sec 60 sec 16 T318 1 254 sec 4 sec 17 T319 1 254 sec 4 sec 18 T320 1 254 sec 30...

Страница 519: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 497 Program 82 ...

Страница 520: ...alog port Input Data Station Port Number 001 128 SL1000 001 120 SL1100 Item No Item Input Data Default 01 CODEC Filter Type 0 Type 0 1 Type 1 2 Type 2 3 Type 3 4 Type 4 5 Type 5 6 Type 6 7 Type 7 8 Type 8 9 Type 9 10 Type 10 11 Type 11 12 Type 12 13 Type 13 14 Type 14 15 Type 15 2 Conditions None Feature Cross Reference Direct Station Selection DSS SL1000 SL1100 ISSUE 3 01 2 498 Program 82 Basic H...

Страница 521: ...tal trunk or analog trunk Input Data Item No Item Input Data Default 01 Sidetone Volume Input Data Digital Sidetone Level Analog Side tone Level 0 54 dB 54 dB 1 48 dB 54 dB 2 42 dB 54 dB 3 36 dB 48 dB 4 30 dB 42 dB 5 24 dB 36 dB 6 18 dB 30 dB 7 12 dB 24 dB 8 12 dB 18 dB 9 12 dB 12 dB 6 Conditions None Feature Cross Reference Central Office Calls Answering Central Office Calls Placing ISSUE 3 01 SL...

Страница 522: ...up 9 0 255 151 10 B1 Filter Setup 10 0 255 41 11 B1 Filter Setup 11 0 255 122 12 B1 Filter Setup 12 0 255 135 13 B1 Filter Setup 13 0 255 168 14 B1 Filter Setup 14 0 255 112 15 B2 Filter Setup 1 0 255 45 16 B2 Filter Setup 2 0 255 1 17 AISN and Analog Gains 0 255 14 18 Z Filter Coefficients 1 0 255 178 19 Z Filter Coefficients 2 0 255 162 20 Z Filter Coefficients 3 0 255 53 21 Z Filter Coefficient...

Страница 523: ...44 R Filter Coefficients 12 0 255 171 45 R Filter Coefficients 13 0 255 74 46 R Filter Coefficients 14 0 255 197 47 X Filter Coefficients 1 0 255 1 48 X Filter Coefficients 2 0 255 17 49 X Filter Coefficients 3 0 255 1 50 X Filter Coefficients 4 0 255 144 51 X Filter Coefficients 5 0 255 1 52 X Filter Coefficients 6 0 255 144 53 X Filter Coefficients 7 0 255 1 54 X Filter Coefficients 8 0 255 144 ...

Страница 524: ...Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 502 Program 82 Basic Hardware Setup for Extension Program 82 ...

Страница 525: ... Volume type means small volume middle volume 1 middle volume 2 large volume Input Data Volume Table Number 1 4 Item No Item Input Data Default 02 Speaker 1 99 Volume Table No 1 18 Volume Table No 2 22 Volume Table No 3 24 Volume Table No 4 34 03 Group Listening 1 99 Volume Table No 1 18 Volume Table No 2 22 Volume Table No 3 28 Volume Table No 4 34 Conditions None Feature Cross Reference None ISS...

Страница 526: ... for Multi Line Telephone Input Data Extension Number Up to four digits SL1000 Up to eight digits SL1100 Item No Item Input Data Default 01 Handset Headset Transmit Gain level 0 Fixed 6 6 5 dB 1 32 LR value 3 5 58 5 dB 0 02 Handset Headset Receive Gain lev el 0 Fixed 15 4 0 dB 1 32 LR value 24 38 0 dB 0 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 504 Program 82 Basic Ha...

Страница 527: ... 128 Item No Item Input Data Description Default 01 CODEC Filter Type 0 Type 0 1 Type 1 2 Type 2 3 Type 3 4 Type 4 5 Type 5 6 Type 6 7 Type 7 8 Type 8 9 Type 9 10 Type 10 11 Type 11 12 Type 12 13 Type 13 14 Type 14 15 Type 15 The CODEC filter operates according to a set value of Program 82 19 when CO DEC filter type 4 is set in this setting 1 Conditions None Feature Cross Reference None ISSUE 3 01...

Страница 528: ...06 B1 Filter Setup 6 0 255 46 07 B1 Filter Setup 7 0 255 169 08 B1 Filter Setup 8 0 255 242 09 B1 Filter Setup 9 0 255 151 10 B1 Filter Setup 10 0 255 41 11 B1 Filter Setup 11 0 255 122 12 B1 Filter Setup 12 0 255 135 13 B1 Filter Setup 13 0 255 168 14 B1 Filter Setup 14 0 255 112 15 B2 Filter Setup 1 0 255 45 16 B2 Filter Setup 2 0 255 1 17 AISN and Analog Gains 0 255 14 18 Z Filter Coefficients ...

Страница 529: ...oefficients 2 0 255 1 35 R Filter Coefficients 3 0 255 58 36 R Filter Coefficients 4 0 255 32 37 R Filter Coefficients 5 0 255 35 38 R Filter Coefficients 6 0 255 202 39 R Filter Coefficients 7 0 255 195 40 R Filter Coefficients 8 0 255 174 41 R Filter Coefficients 9 0 255 74 42 R Filter Coefficients 10 0 255 51 43 R Filter Coefficients 11 0 255 170 44 R Filter Coefficients 12 0 255 171 45 R Filte...

Страница 530: ...55 X Filter Coefficients 9 0 255 1 56 X Filter Coefficients 10 0 255 144 57 X Filter Coefficients 11 0 255 1 58 X Filter Coefficients 12 0 255 144 59 GR Filter Coefficients 1 0 255 1 60 GR Filter Coefficients 2 0 255 17 61 GX Filter Coefficients 1 0 255 35 62 GX Filter Coefficients 2 0 255 32 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 508 Program 82 Basic Hardware Setu...

Страница 531: ...pe means small volume middle volume 1 middle volume 2 large volume Input Data Volume Table Number 1 4 Item No Item Input Data Default 02 Speaker 1 99 Volume Table No 1 18 Volume Table No 2 22 Volume Table No 3 24 Volume Table No 4 34 03 Group Listening 1 99 Volume Table No 1 18 Volume Table No 2 22 Volume Table No 3 28 Volume Table No 4 34 Conditions None Feature Cross Reference None ISSUE 3 01 SL...

Страница 532: ...ata Description Default 01 Sensor Type 0 Close Detect 1 Open Detect Set sensor type 0 02 Sensor Alarm Detect Minimum Level 1 255 5 ms 1275 ms Set minimum level for Alarm detection 24 120 ms 03 Sensor Idle Detect Minimum Level 1 255 5 ms 1275 ms Set minimum level for Idle detection 24 120 ms Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 510 Program 82 Basic Hardware Setup ...

Страница 533: ...G 729 au dio frames 1 6 3 06 G 729 VAD mode 0 Disable 1 Enable 0 07 G 729 Jitter Buf fer min 0 300 ms 30 08 G 729 Jitter Buffer average 0 300 ms 60 09 G 729 Jitter Buffer max 0 300 ms 120 11 Number of G 723 au dio frames 1 2 1 15 Jitter Buffer Mode 1 Fixed 3 Self adjusting 3 16 G 711 Jitter Buf fer min 0 255 ms 30 17 G 711 Jitter Buffer average 0 255 ms 60 18 G 711 Jitter Buffer max 0 255 ms 120 1...

Страница 534: ...ting 1 Training signal TCF of the fax is locally gen erated and checked 2 Training signal TCF of the fax is sent over the network 1 59 FAX Relay Function 0 Disable 1 Enable 2 Each port mode 0 61 Auto Gain Control 0 5 0 62 DTMF Relay Mode 0 VoIPDB 1 RFC2833 2 H 245 3 Disable Set up information of VoIPDB is set by Program 84 06 10 0 63 Number of G 722 au dio frames 1 4 1 10 ms 2 20 ms 3 30 ms 4 40 m...

Страница 535: ...Item No Item Input Data Description Default 71 DTMF Level Low 1 33 dBm 28 6 dBm 28 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 513 Program 84 ...

Страница 536: ...5 Capability Exchange Timer 0 255 seconds 5 10 H 245 Logical Channel Establish ment Timer 0 255 seconds 50 11 H 245 Mode Request Procedures Timer 0 255 seconds 50 12 H 245 Close Logical Channel Timer 0 255 seconds 50 13 H 245 Round Trip Delay Timer 0 255 seconds 50 14 H 245 Maintenance Loop 0 255 seconds 50 15 RAS GRQ Timer 0 255 seconds 5 16 GRQ Retry Count 0 255 2 17 RAS RRQ Timer 0 255 seconds ...

Страница 537: ...econds 3 32 RAI Retry Count 0 255 2 33 Call Signaling Port Number 0 65535 0 1719 1721 65535 1730 35 Fast Start Mode 0 Disable 1 Enable 1 36 RAS Unicast Port Number 0 65535 20001 37 Terminal Type setting 0 255 60 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 515 Program 84 ...

Страница 538: ...Item Input Data Description Default 01 Server Mode 0 TFTP 1 FTP 0 02 File Server IP Ad dress 0 0 0 0 126 255 255 254 128 0 0 1 191 255255 254 192 0 0 1 223 255 254 254 0 0 0 0 03 Login Name Up to 20 Characters Enable only 84 07 01 is 1 None 04 Password Up to 20 Characters Enable only 84 07 01 is 1 None Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 516 Program 84 Hardware ...

Страница 539: ...from LAN I F on VoIPDB is set the VLAN tag Input Data Interface Number 1 2 Item No Item Input Data Default 01 VLAN 0 Disable Off 1 Enable On 0 02 VLAN ID 0 4094 0 03 Priority 0 7 0 Conditions System programming must be exited before these program options take affect Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 517 Program 84 ...

Страница 540: ... 0 02 Priority IP Prece dence 0 7 0 Low 7 High 1 Router queuing priority 0 03 Low Delay 0 1 0 Normal Delay Low Delay 1 Optimize for low delay routing 0 04 Wideband Through out 0 1 0 Normal Throughput 1 High Throughput 1 Optimize for high bandwidth routing 0 05 High Reliability 0 1 0 Normal Reliability 1 Low Reliability 1 Optimize for reliability routing 0 07 Priority D S C P Differentiated Serv ic...

Страница 541: ...uf fer Maximum 0 255 ms Set the maximum value of the G 711 Jitter Buffer 80 07 G 729 Audio Frame 1 6 1 10 ms 2 20 ms etc Maximum number of G729 Audio Frames G 729 assumes the audio signal made by a specimen by 8 kHz and the frame of 10 ms is as sumed to be a unit to 8 kbps by the encoding compressed method 2 08 G 729 Silence Compression VAD Mode 0 Disable 1 Enable Select whether to compress silenc...

Страница 542: ...Gain Control 0 5 Define the Auto Gain Control 0 31 DTMF Payload Number 96 127 Define the DTMF Payload Number 110 32 DTMF Relay Mode 0 Disable 1 RFC2833 Determine the DTMF setup 0 33 G 722 Audio Frame 1 10 ms 2 20 ms 3 30 ms 4 40 ms Maximum number of G 722 Audio Frames G 722 assumes the audio signal made by a specimen by 16 kHz and the frame of 10 ms is as sumed to be a unit to 64 kbps by the encod...

Страница 543: ...riving and the buffer allows this variation to be absorbed 30 46 iLBC Jitter Buffer Standard 0 255 ms Set the average iLBC Jitter Buffer 60 47 iLBC Jitter Buffer Maximum 0 255 ms Set the maximum iLBC Jitter Buffer 120 48 ILBC Payload Number 96 127 The payload number of iLBC is set However the same number as Item 31 cannot be set 98 49 RTP Filter 0 Disable 1 Enable 0 50 Fax Relay mode 0 Disable 1 E...

Страница 544: ...1 and G 729 are targets at this time 0 66 Voice Band Data VBD V2 0 Add ed 0 Disable 1 Enable This PRG is used for setting VBD to is Enable Disable This PRG is necessary to set the 1 Special in PRG15 03 03 for target terminal 0 15 03 03 67 VBD Payload Type V2 0 Add ed 96 127 This PRG is specifies the Payload Type number used by VBD 97 15 03 03 Conditions None Feature Cross Reference None SL1000 SL1...

Страница 545: ...seconds 40 4000 ms 06 SIP Trunk Port Num ber 1 65535 5060 07 Session Timer Value 0 65535 0 08 Minimum Session Timer Value 0 65535 1800 09 Called Party Informa tion 0 Request URI 1 To Header 0 10 URL Type 0 SIP URL 1 TEL URL 0 11 URL To HeaderSet ting Information V3 0 Added 0 Proxy Server Do main 1 SIP UA Domain 0 13 SIP Trunk Incoming Outgoing via E164SIP_URI V1 5 Added 0 Off 1 Mode 1 V3 0 Changed...

Страница 546: ...Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 524 Program 84 Hardware Setup for VoIPDB Program 84 ...

Страница 547: ...e When set to 1 Enable the registration in formation is automatically deleted for H 323 0 02 Keep Alive Message Interval 1 10 minutes Time interval that system sends a Ping to the terminal 1 03 Keep Alive Message Timeout 1 10 seconds Time that system waits for a Ping re sponse from the terminal 5 04 Keep Alive Timeout 1 5 times How many times the system waits for a non response before determining ...

Страница 548: ...Limiter Control Gain 0 30 15 dBm 15 dBm 0 15 dBm 1 14 dBm 15 0 dBm 29 14 dBm 30 15 dBm Gain setting to control limiter in the direc tion of PCM IP This option adds the gain to the voice input from highway and removes it from the voice output to the LAN 15 0 dBm 03 RX Limiter Control Gain COIU 0 30 15 dBm 15 dBm 0 15 dBm 1 14 dBm 15 0 dBm 29 14 dBm 30 15 dBm This option controls the limiter gain fo...

Страница 549: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 527 Program 84 ...

Страница 550: ... 711 Jitter Buffer 80 07 G 729 Audio Frame 1 6 1 10 ms 2 20ms etc Maximum number of G729 Audio Frames G 729 assumes the audio signal made by a specimen by 8 kHz and the frame of 10 ms is assumed to be a unit to 8 kbps by the encoding compressed method 2 08 G 729 Silence Com pression VAD Mode 0 Disable 1 Enable Select whether to compress silence with G 729 When there is silence the RTP packet is no...

Страница 551: ...e when a terminal call is made through the VoIPDB 0 33 G 722 Audio Frame 1 10 ms 2 20 ms 3 30 ms 4 40 ms Maximum number of G 722 Audio Frames G 722 assumes the audio signal made by a specimen by 16 kHz and the frame of 10 ms is assumed to be a unit to 64 kbps by the encoding compressed method 3 35 G 722 Jitter Buffer Minimum 0 255 ms Set the minimum value of the Jitter Buffer of G 722 is set Jitte...

Страница 552: ...um iLBC Jitter Buffer 120 48 ILBC payload number 96 127 The payload number of iLBC is set How ever the same number as Item 31 cannot be set 98 49 RTP Filter 0 Disable 1 Enable 1 50 Fax Relay mode 0 Disable 1 Enable 0 51 T 38 Protocol mode 0 R U V1 5 Changed 1 U R V1 5 Changed 2 RTP V1 5 Changed 3 UDPTL V1 5 Changed 1 52 Fax Max Rate 1 V 27ter 4800 bps 3 V 29 9600 bps 5 V 17 14400 bps 5 56 Low Spee...

Страница 553: ...ult 01 Registrar Proxy Port 1 65535 5070 02 Session Timer Value 0 65535 180 03 Minimum Session Timer Value 0 65535 180 04 Called Party Info 0 Request URI 1 To Header 0 05 Expire Value of Invite 0 256 seconds Arrival of a message is ended when this time expires and there is no cut from the caller 180 06 Expire Value of Invite send 1 3600 seconds The expiration time is set for the Invite message 180...

Страница 554: ...1 No Setting 02 Password Up to 16 characters Input the Password when using manual or auto registration 10 46 01 Web pro indicates password as mark V3 0 Added SL1100 No Setting 03 User ID Omission 0 Off 1 On Input the Personal ID from terminal auto matically when log on again 0 04 Log Off 0 Off 1 On Input the Personal ID from terminal auto matically when log on again 1 05 Nick Name Up to 32 charact...

Страница 555: ...ve time for supervising the Voice Path 180 04 Minimum Session Ex pire Timer 60 65535 seconds Set minimum value of effective time for su pervising the Voice Path 180 05 Invite Expire Timer 60 65535 seconds Set effective time for Incoming Outgoing call when the Expire value is not set in the INVITE message received from DR700 terminal 180 06 Signal Type of Serv ice 0x00 0xFF 0 9 A F Set Type of Serv...

Страница 556: ...m No Item Input Data Description Default 14 Refer Expire Timer 0 65535 seconds 60 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 534 Program 84 Hardware Setup for VoIPDB Program 84 ...

Страница 557: ...s silence with G 711 When there is silence the RTP packet is not sent When VAD is enabled the CPU will stop sending silence packets but the IP phone will continue to transmit silence packets 0 03 G 711 Type 0 A law 1 μ law Set the type of G 711 0 04 G 711 Jitter Buffer Minimum 0 255 ms Set the minimum value of the G 711 Jitter Buffer 20 05 G 711 Jitter Buffer Standard 0 255 ms Set the average valu...

Страница 558: ...e voice level judged to be silence Change value based 30 This entry is ignored if silence compres sion is disabled in 84 01 03 with G 711 or 84 01 06 with G 729 20 28 Priority Codec Setting 0 G711 PT 2 G729 PT 3 G 722 PT The option selected here determines what other codec options are applied by priority 0 30 EchoAuto Gain Con trol 0 5 Define the Auto Gain Control 0 31 DTMF Payload Num ber 96 127 ...

Страница 559: ...Level mode 0 Use the Default of VoIPDB Unit 1 Use the Main Sys tem 0 39 DTMF Level High 1 33 dBm 28 6 dBm 28 40 DTMF Level Low 1 33 dBm 28 6 dBm 28 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 537 Program 84 ...

Страница 560: ...ber 0 VoIPDB GW Number GW Number will not be shown in Telephone Programming mode 1 Item No Item Input Data Default 01 IP Address xxx xxx xxx xxx 172 16 0 20 02 RTP Port Number 0 65534 VoIP GW 1 10020 10051 03 RTCP Port Number RTP Port Number 1 VoIPDB GW1 10021 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 538 Program 84 Hardware Setup for VoIPDB Program 84 ...

Страница 561: ...em uses another CODEC except G 723 Mode 1 means the system uses all CO DECs but the limitation of the total num ber of available DSP will be applied 0 03 SRTP Mode Setup 0 Disable 1 Enable 0 04 SRTP Mode Select 0 Mode1 0 06 H 245 Port Number 0 65535 10100 07 Preparation Comple tion Response Port Number 0 65535 4000 08 DTMF Duration 0 Use RFC2833 25 2000 ms 0 09 DTMF Pause 0 Use RFC2833 25 2000 ms ...

Страница 562: ...to distinguish DTMF tones If the signal is shorter than the value set the signal is deemed not a DTMF 2 38dbm 17 DTMF Detect Mini mum S N Ratio 0 9db 1 8db 6 3db 7 2db 8 1db 9 0db This is a frequency ratio setting of the DTMF for the frequency other than the DTMF tone When this value comes to 0db the DTMF is distinguished only when the signal level except DTMF is low In case of wrong DTMF detectio...

Страница 563: ... to set the firmware name to download for the IP Phone Input Data Terminal Type 1 3 Not used 4 IP4WW 24TIXH Item No Item Input Data Default 01 Firmware Directory Maximum 64 characters No Setting 02 Firmware File Name Maximum 30 characters No Setting Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 541 Program 84 ...

Страница 564: ...ed 4 Type 4 reserved 5 Type 5 reserved Item No Item Input Data Default 01 Audio Capability 1 G 711 A law 2 G 711 μ law 3 G 729 5 G 722 1 02 Number of Audio Frames 1 4 V2 0 Changed 1 10 ms G 711 G 722 G 729 2 20 ms G 711 G 722 G 729 3 30 ms G 711 G 722 G 729 4 40 ms G 711 G 722 G 729 5 50 ms G 729 V2 0 Deleted 6 60 ms G 729 V2 0 Deleted 2 03 RTP Filter 0 Disable 1 Enable 1 Conditions None Feature C...

Страница 565: ...etting unless asked to change by engineer Select comfort noise as background noise Effective when PRG 84 31 01 1 1 84 31 01 04 TDM Echo Can celler NLP Threshold 0 15 12 05 TDM Echo Can celler Tail Dis placement V2 0 Added 0 89 0 ms 890 ms Do not change the setting unless asked to change by engineer Effective when PRG 84 31 01 1 0 84 31 01 06 TDM Echo can celler tail length V2 0 Added 1 32 ms 2 48 ...

Страница 566: ...Bm 7 21 dBm 11 9 dBm 12 6 dBm Do not change the setting unless asked to change by engineer Select target gain Effective when PRG 84 31 10 2 7 84 31 10 13 TDM Tx HLC Threshold 0 42 42 0 dBm 0 42 dBm 1 41 dBm 42 0 dBm 41 14 TDM Tx Gain Compression mode 0 Disable 1 Enable 1 15 TDM Tx Gain Compression Threshold 0 42 dBm 1 41 dBm 42 0 dBm 41 16 TDM Rx Level Control V2 0 Added 0 Disable 1 RX Level Contr...

Страница 567: ...eer Effective when PRG 84 31 19 1 0 84 31 19 24 RTP Echo Can celler Tail Length V2 0 Added 1 32 ms 2 48 ms 3 64 ms 4 80 ms 5 96 ms 6 112 ms 7 128 ms Do not change the setting unless asked to change by engineer Select length of echo Effective when PRG 84 31 19 1 7 84 31 19 25 RTP Echo Can celler Default ERL Level V2 0 Added 0 6 9 dB 9 dB 0 9 dB 1 6 dB 2 3 dB 5 6 dB 6 9 dB Do not change the setting ...

Страница 568: ...1 Type 8 36 Type 9 11 15 42 34 RTP Rx Level Control V2 0 Added 0 Disable 1 RX Level Control Mode 2 RX Automatic Level Control Flag Do not change the setting unless asked to change by engineer Select receive level control mode 0 35 RTP Rx Level Control Level V2 0 Added 0 16 24 dB 24 dB 0 24 dB 1 21 dB 8 0 dB 15 21 dB 16 24 dB Do not change the setting unless asked to change by engineer Select recei...

Страница 569: ...Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 547 Program 84 ...

Страница 570: ...lation Date to define the installation date of the system Input Data Item No Item Input Data Default 01 Year 00 99 00 No Setting 02 Month 01 12 00 No Setting 03 Day 01 31 00 No Setting Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 548 Program 90 Maintenance Program Program 90 ...

Страница 571: ...level password can access to SB programs only It is NOT recommended to change these data If you must change these Data make sure you keep the ID Password or you will never be able to enter the program unless you clear all the System Data Setting Input Data User Number 1 8 Item No Item Input Data Default 01 User Name Maximum 10 characters Refer below 02 Password Up to eight digits Refer below 03 Us...

Страница 572: ... Description 5 user1 1111 5 UA User Programming Administer Mode Lev el 1 Conditions More than one extension can be in the programming mode Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 550 Program 90 Maintenance Program Program 90 ...

Страница 573: ...ta Input Data Item No Item Input Data Default 01 Save Data Dial 1 press Hold Press Hold only to cancel Conditions Before Uploading Customer Database please make sure you reset the system either by using 90 08 or Power down up the system When installing a compact flash card onto the PZ VM21 the system MUST be powered off Never install or uninstall the compact flash card while the system is under po...

Страница 574: ...ly to cancel Conditions After uploading the data the display will change to a next Program Then make sure you EXIT the Program order for upload to complete Now some of the setting needs to have system reset order for setting to be effective example IP Address Line Key Assignment so we Recommend to reset the system When installing a compact flash card onto the PZ VM21 the system MUST be powered off...

Страница 575: ...ously used the slot should be deleted option 1 first before installing the new interface unit Reset allows you to send a reset code Input Data Menu Number 1 Delete 2 Reset 3 Set Busy Out 4 Reset Busy Out Item No Item Input Data Default 01 Slot Control Slot Number 0 16 SL1000 0 9 SL1100 Conditions When you delete or reset a unit you must first remove it from its slot then run Program 90 05 When reu...

Страница 576: ... unit switch down Once busied out none of the ports on the unit can be used for new calls Existing calls however are not torn down Input Data Menu Number 0 Set Busy Out 1 Reset Busy Out idle Item No Item Input Data Default 01 Trunk Control Trunk Port Number 001 126 SL1000 001 096 SL1100 1 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 554 Program 90 Maintenance Program Pro...

Страница 577: ...ough PC Programming Use Program 90 07 Station Control for extension maintenance Input Data Menu Number 1 Hardware Reset 2 Software Reset Item No Item Input Data Default 01 Extension Control Extension Number up to four SL1000 eight SL1100 digits Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 555 Program 90 ...

Страница 578: ...ogram 90 08 System Reset to perform a system reset Input Data Item No Item Input Data Default 01 System Reset Dial 1 press Hold Press Hold key only to can cel Conditions Some of changes made to a program may need to reset the system order for the change to be effective Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 556 Program 90 Maintenance Program Program 90 ...

Страница 579: ...nput Data Default 01 Month 00 12 If the Month is set to 00 and Day is set the sys tem is automatically reset every month on the predefined day 00 02 Day 00 31 If the Day is set to 00 and the Time Hour and Minute is set the system automatically resets every day at the predefined time 00 03 Hour 00 23 00 04 Minute 00 59 00 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Program...

Страница 580: ... failed to ini tialize 2 The PKG did not start normally 1 PKG not inser ted firmly 2 PKG was re moved but not reinserted firmly 3 Old PKG data still reported due to no initi alization 1 Insert PKG firmly 2 Insert PKG firmly 3 Delete slot in formation in Program 90 05 and in sert the PKG again During initiali zation the PKG is rec ognized ERR REC 2 2 0 PKG Mounting Error The unit did not step on a ...

Страница 581: ...esides the equipment with the possi bility of the noise source 4 Please sepa rate as much as possible and use a main device from the equipment by which you seem may generate the radiation noise 5 Please ground the chassis correctly When unit is confirmed the error is recovered ERR REC 4 2 0 PKG S W Download Error The unit pro gram could not be downloaded normally The unit could not able to be star...

Страница 582: ...e setting of Program 10 03 does not corre spond to an actual line 1 Confirm the data of Pro gram 10 03 2 Confirm wiring and the instal lation of DSU 3 Check with the manufacturer if the problem occurs again When the connection returns nor mally the er ror is recov ered ERR REC 11 0 0 CTI Link Error The link with the CTI server came off 1 LAN cable de fective 2 Connected HUB broken 3 The CTI serv e...

Страница 583: ... or Programming change is made No action needed 54 2 0 License Manage ment Ta ble Full A new TCP IP terminal and the DSP board were not able to be added to the ap plication license management ta ble The license management table is regis tering full Maximum 512 li cense information on the TCP IP ter minal is registered and a new terminal cannot be regis tered Please delete li cense information on a...

Страница 584: ...outer is wrong 3 It is an error to the link of LAN 4 Net side trou ble 1 Confirm the following sys tem data set ting Pro grams 10 12 10 28 10 29 10 30 and 10 36 2 Confirm the setting of rout ers 3 Confirm whether ab normality oc curs on the net side 4 Confirm the authentication system data setting 5 Confirm wiring and the sys tem data set ting Please in quire on un certain points of the maker The ...

Страница 585: ...to which the SIP extension terminal was turned on at REGISTER Wrong number of licenses 1 Confirm the number of li censes for SIP extension ter minals 2 Check with maker on un certain points When the number of registration of SIP extension terminals falls below the number of li censes WAR 67 0 0 SIP illegal Packet received The system re ceived illegal packet A client or network was illegal state Ch...

Страница 586: ...Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 564 Program 90 Maintenance Program Program 90 ...

Страница 587: ...mail address to which the report should be sent No Setting 09 Reply Address Up to 255 Characters When alarm reports are e mailed set the e mail address where replies should be e mailed No Setting 10 From Address Up to 255 Characters When alarm reports are e mailed set this e mail address for the sta tion sending the report No Setting 11 DNS Primary Ad dress 0 0 0 0 255 255 255 255 When alarm repor...

Страница 588: ... 0 Added 0 No 1 Yes PRG 90 11 14 YES PRG 47 18 SMTP Client uses and CF mount are necessary In the case of System Fault Dim last gz and Dimdump gz are noti fied 0 90 11 14 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 566 Program 90 Maintenance Program Program 90 ...

Страница 589: ... the output port to be used as the output for system alarm report and set the system alarm options The system can have up to 50 reports Input Data Item No Item Input Data Description Default 01 Output Port Type 0 No setting 5 Compact Flash Indicate the type of connection used for the System Alarms 0 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 567 Prog...

Страница 590: ...ta Item No Item Input Data Description Default 01 Output Port Type 0 No setting 5 Compact Flash Indicate the type of connection used to print the system information 0 05 Output Command Dial 1 press Hold Press Hold only to can cel This program only be able to access by Telephone programming Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 568 Program 90 Maintenance Program Pr...

Страница 591: ...display the main software information on the CPU Input Data Item No Item Input Data Default 01 Version Number Read Only 01 00 99 99 ASCII Code 5 Bytes 02 Software Release Date Read Only May 22 2002 17 53 46 ASCII Code 20 Bytes Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 569 Program 90 ...

Страница 592: ...nformation to display the firmware versions of the various system units Input Data Item No Item Input Data Default 01 DSP Firmware Version No Read Only 00 00 00 00 15 15 15 15 BCD Code 2 Byte Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 570 Program 90 Maintenance Program Program 90 ...

Страница 593: ...eased from the Dial Block restriction Input Data Extension Number Up to four digits SL1000 Up to eight digits SL1100 Item No Item Input Data Description Default 01 Delete IP Telephone Release Dial 1 press Hold Press Hold only to can cel This assignment removes the station num ber association with the MAC address of the IP station Conditions None Feature Cross Reference Code Restriction Toll Restri...

Страница 594: ...val ue 0 05 Dial Tone Detector Busy Output 0 Not Detected 1 256 Report when the data reaches the defined val ue 0 06 Caller ID Receiver Busy Output 0 Not Detected 1 256 Report when the data reaches the defined val ue 0 07 Voice Mail Channel All Busy Output 0 Not Detected 1 256 Report when the data reaches the defined val ue 0 09 Attendant Channel All Busy Output 0 Not Detected 1 256 Report when th...

Страница 595: ...Feature Cross Reference Traffic Reports ISSUE 3 01 SL1000 SL1100 Programming Manual 2 573 Program 90 ...

Страница 596: ...Traffic Report Output to define the output port to be used as the traffic report output Input Data Item No Item Input Data Default 01 Output Port Type 0 No setting 3 LAN 0 Conditions None Feature Cross Reference Traffic Reports SL1000 SL1100 ISSUE 3 01 2 574 Program 90 Maintenance Program Program 90 ...

Страница 597: ...o delete the registered IP telephone from the system Input Data Extension Number Up to four digits SL1000 Up to eight digits SL1100 Item No Item Input Data Description Default 01 Delete IP Telephone Delete Dial 1 press Hold Press Hold only to can cel This assignment removes the station num ber association with the MAC address of the IP station Conditions None Feature Cross Reference None ISSUE 3 0...

Страница 598: ...cation Time Setup to set the date and time for the alarm report to print Input Data Notification Number 1 12 Item No Item Input Data Default 01 Month 00 12 0 Not Set 00 02 Day 00 31 0 Not Set 00 03 Hour 00 23 00 04 Minute 00 59 00 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 576 Program 90 Maintenance Program Program 90 ...

Страница 599: ... Alarm Report CC Mail Setup to define the mail address to receive the system alarm report CC Mail setup Input Data CC Number 1 5 Item No Item Input Data Default 01 CC Mail Address Up to 255 Characters No Setting Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 577 Program 90 ...

Страница 600: ... Input Data Program Numbers 1001 9903 Item No Item Input Data Default 01 Maintenance Level Level 1 MF Level Level 2 IN Level Level 3 SA Level Level 4 SB Level Refer to the Level indi cation for each individ ual program located in the upper left corner at the beginning of each program Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 578 Program 90 Maintenance Program Program ...

Страница 601: ...ssword Setup to set the password used to enter the user programming mode Input Data Extension Numbers Maximum four digits SL1000 Maximum eight digits SL1100 Item No Item Input Data Default 01 Password Fixed four digits 1111 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 579 Program 90 ...

Страница 602: ...ame and password DIM is a maintenance tool used by engineering to extract trace level information Input Data Item No Item Input Data Default 01 Access Enabling 0 Disable 1 Enable 0 Disable 02 Username 20 characters alphanumeric SL1000 SL1000 SL1100 SL1100 03 Password 20 characters alphanumeric 12345678 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 580 Program 90 Maintenan...

Страница 603: ...cel Refer below 08 Malaysia Dial 1 press Hold Press Hold only to cancel Refer below 09 Thailand Dial 1 press Hold Press Hold only to cancel Refer below 10 India Dial 1 press Hold Press Hold only to cancel Refer below Default China Program No Name Default 10 02 01 Country Code 86 For China 14 02 09 Busy Tone Detection 1 All trunks On 14 02 18 Busy Tone Detection on talking 1 All trunks On 15 03 15 ...

Страница 604: ... Busy Tone for Trunk 9 80 04 09 OFF max time Busy Tone for Trunk 12 80 04 12 Frequency No 1 Busy Tone for Trunk 2 80 04 14 Twit Level Rcv1 Rcv2 Rcv3 1 80 05 01 Date Format 1 yy mm dd 80 07 Call Progress Tone Detector Frequency Setup Table2 45 81 01 09 Time ringing signal stop detection time 70 4 5 s 82 04 08 Maximum hook flash time 132 660 ms 15 03 09 Caller ID Function 1 15 03 14 Forwarded Caller...

Страница 605: ...oup listening service 1 Class 1 15 20 13 31 Connected Line identification COLP 1 Class 1 15 21 01 06 Dial pause at first digit 1 21 08 01 Time of Repeat Dial 5 21 08 02 Interval of Repeat Dial 15 21 08 03 Repeat Dial Calling Timer 10 24 02 01 Transfer to busy extension 1 24 02 03 No answer time for call forward 30 25 07 07 DISA Conversation Warning Tone Time 0 25 07 08 DISA Conversation Disconnect...

Страница 606: ...0 081 PmitTBL 4 110 119 21 06 07 Restriction table TollRes 1 0204 TollRes 2 00 01 0204 100 108 TollRes 3 0 100 18 108 TollRes 4 31 02 01 Internal Paging Group Assignment 1 All stations 31 02 02 Internal Paging Group Assignment 1 All stations 14 02 10 Caller ID 1 Trunks 1 27 14 02 16 Caller ID signal 1 Trunks 1 27 22 04 01 Incoming Extension Ring Group Assignment Set to 200 207 IRG1 11 09 01 Trunk ...

Страница 607: ...2 30 20 19 02 Caller ID Wait Timer 2 20 07 01 Manual Night Service Enabled 1 Class 1 only 25 03 01 DID DISA Transfer Ring Group With Incorrect Dial ing 1 Trunks 1 27 Mode 1 25 04 01 DID DISA Transfer Ring Group With No Answer Busy 1 Trunks 1 27 Mode 1 25 07 02 DID DISA No Answer Time 16 25 07 11 DID DISA Answer Delay Timer 3 32 02 01 Door Box Ring Assignment Set to EXT 200 207 DOOR 1 Mode 1 2 40 0...

Страница 608: ...p 1 only 12 02 01 Automatic night service Patterns 01 02 set to 17 30 Mode Group 1 only 10 02 01 Country Code 886 80 01 01 Repeat count 6 Korea Program No Name Default 10 02 01 Country Code 82 11 01 01 Dial Digit 1 11 09 02 2nd TRK Access 6 11 10 20 Ope VRS Msg 716 11 12 27 Call Pickup 12 02 01 Automatic night service Patterns Start of time ModeGrp 1 4 Time Pattern 01 Set Time 01 00 00 ModeGrp 1 4...

Страница 609: ...01 Long Conversation Alarm 0 20 13 22 Call Party Status 1 20 17 01 Attendant 200 20 19 02 Caller ID wait timer 0 21 01 06 1st Digit P 1 21 01 09 Hotline Start 3 21 04 01 T R Class for Extension 1 21 05 07 Permit code table Class 1 set 1 Class 2 set 2 Class 3 set 3 Class 4 set 4 21 06 06 Permit code table PmitTBL 1 None PmitTBL 2 119 112 113 080 21 05 08 Restriction Table Class 1 set 1 Class 2 set ...

Страница 610: ...ble 2 48 table 3 62 81 01 09 Signal Stop Dtct 80 81 01 14 Flash Hooking 1 20 81 01 15 Flash Hooking 2 30 81 07 01 CODEC Filter Setup for analog Trunk Ports 0 Trunks 1 27 82 04 04 Max Break TM 14 82 04 07 Min Flash TM 17 82 04 08 Max Flash TM 120 Hong Kong Program No Name Default 14 01 13 Loop Disconnect Supervision 1 Trunks 1 27 14 02 02 Ring Detect Type 1 Trunks 1 27 14 02 04 Flash for Timed Flas...

Страница 611: ...80 01 03 Tone 39 Special Audible Ring Busy Tone Unit1Duration 10 80 01 03 Tone 39 Special Audible Ring Busy Tone Unit2Duration 20 80 04 12 TONE RCV2 Frequency 1 2 80 04 13 TONE RCV2 Frequency 2 3 80 07 01 Table 2 Frequency 48 80 07 01 Table 3 Frequency 62 81 01 14 Flash Hooking 1 25 81 07 01 CODEC Filter Type for analog trunk port 0 Trunks 1 27 10 02 01 Country Code 852 Brazil Program No Name Defa...

Страница 612: ... 01 Sunday 3 ModeGrp 1 12 07 01 Text Data for Night Mode Day Night Mode 1 Dia Mode Grp 1 Day Night Mode 2 Noite Mode Grp 1 Day Night Mode 3 Almoço Mode Grp 1 Day Night Mode 4 Mode Grp 1 Day Night Mode 5 Mode Grp 1 Day Night Mode 6 Mode Grp 1 Day Night Mode 7 Mode Grp 1 Day Night Mode 8 Mode Grp 1 14 01 01 Trunk Name Linha 01 51 14 01 13 Loop Disconnect Supervision 1 All Trunk 14 01 14 Long Convers...

Страница 613: ...isconnect 1 Class 01 15 20 13 01 Long Conversation Alarm 0 Class 01 15 20 15 01 Normal Incoming Call of Trunk 11 20 15 03 Internal Incoming Call 10 20 15 05 DID 11 20 15 09 Call Back 10 20 16 01 Selectable Display Message Message Number 1 REUNIÃO_ Message Number 2 SERVIÇO_EXTERNO Message Number 3 RETORNA_ Message Number 4 LIGAR _ Message Number 5 LIGAR_APÓS_ Message Number 6 ALMOÇO Message Number ...

Страница 614: ...l Analysis Table number 170 091 Dial Analysis Table number 171 092 Dial Analysis Table number 172 093 Dial Analysis Table number 173 094 Dial Analysis Table number 174 095 Dial Analysis Table number 175 096 Dial Analysis Table number 176 097 Dial Analysis Table number 177 098 Dial Analysis Table number 178 099 Dial Analysis Table number 179 1 Dial Analysis Table number 180 2 Dial Analysis Table nu...

Страница 615: ... Analysis Table number 166 1 Dial Analysis Table number 167 1 Dial Analysis Table number 168 1 Dial Analysis Table number 169 1 Dial Analysis Table number 170 1 Dial Analysis Table number 171 1 Dial Analysis Table number 172 1 Dial Analysis Table number 173 1 Dial Analysis Table number 174 1 Dial Analysis Table number 175 1 Dial Analysis Table number 176 1 Dial Analysis Table number 177 1 Dial Ana...

Страница 616: ...ble number 162 10 Dial Analysis Table number 163 10 Dial Analysis Table number 164 10 Dial Analysis Table number 165 10 Dial Analysis Table number 166 10 Dial Analysis Table number 167 10 Dial Analysis Table number 168 10 Dial Analysis Table number 169 10 Dial Analysis Table number 170 10 Dial Analysis Table number 171 10 Dial Analysis Table number 172 10 Dial Analysis Table number 173 10 Dial Ana...

Страница 617: ... Analysis Table number 157 2 Dial Analysis Table number 158 2 Dial Analysis Table number 160 2 Dial Analysis Table number 161 2 Dial Analysis Table number 162 2 Dial Analysis Table number 163 2 Dial Analysis Table number 164 2 Dial Analysis Table number 165 2 Dial Analysis Table number 166 2 Dial Analysis Table number 167 2 Dial Analysis Table number 168 2 Dial Analysis Table number 170 2 Dial Ana...

Страница 618: ...aximum Time Type 2 BT 8 80 04 08 Off Minimum Time Type 2 BT 6 80 04 09 Off Maximum Time Type 2 BY 8 80 07 01 Frequency Table 1 42 80 08 01 Duration 200 82 04 04 Maximum Break Time 14 82 04 06 Maximum Make Time 14 82 04 07 Minimum Hook Flash Time 16 82 04 08 Maximum Hook Flash Time 70 10 02 01 Country Code 55 15 02 01 Display Language Selection 1 47 02 16 Voice Prompt Language 13 47 06 14 Voice Pro...

Страница 619: ...40 32 2 1 10 32 3 4 External Busy Tone TONE 46 1 0 0 2 32 2 0 1 2 32 Malaysia Program No Name Default 10 02 01 Country Code 60 Thailand Program No Name Default 10 02 01 Country Code 66 India Program No Name Default 10 02 01 Country Code 91 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 597 Program 90 ...

Страница 620: ...lt 01 Package Name Read Only PKG Name 02 Firmware Version Number Read Only 00 00 15 15 03 VOIPDB Software Version Read Only DEV PR REL 00 00 00 00 00 00 DEV PR REL FF FF FF FF FF FF 04 DSP Project Number Read Only 00000000 FFFFFFFF 05 Vocallo Firmware Version Read Only 00 00 00 00 FF FF FF FF 06 OCT1010ID Version Read Only 00 00 00 00 FF FF FF FF Conditions None Feature Cross Reference None SL1000...

Страница 621: ...el Setup to set the maintenance level for Wizard Programming Input Data Wizard Number 1 250 Item No Item Input Data Default 01 Maintenance Level 0 All Display Data 3 SB System Administrator B Display Data 4 SA System Administrator A Display Data 5 IN Installer Level Display Data 6 MF Manufacture Level Display Data 0 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming ...

Страница 622: ...pdate the firmware us ing a compact flash card Time registration fails if an expired time is registered 02 Update mode Read Only 0 Non Active 1 Activated 0 Activate the Firmware Update feature If this setting is 1 new firmware on the compact flash card updates according to the setting at 90 36 01 03 Update Report Read Only Maximum 256 charac ters Output a report when the update is executed and sav...

Страница 623: ...Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 601 Program 90 ...

Страница 624: ...e Switching 0 Turn Off 1 Turn On 1 Turn On 12 04 07 DISA User ID Setup 0 Turn Off 1 Turn On 1 Turn On 25 08 08 Mail Box Setup 0 Turn Off 1 Turn On 1 Turn On 40 02 09 Text Messages Setup 0 Turn Off 1 Turn On 1 Turn On 20 16 10 Incoming Ring Group Setup 0 Turn Off 1 Turn On 1 Turn On 22 04 11 Abbreviated Dial Number and Name 0 Turn Off 1 Turn On 1 Turn On 11 10 04 13 04 12 Night mode switching Other...

Страница 625: ... 28 25 Programmable Function Key 0 Turn Off 1 Turn On 1 Turn On 15 07 26 Virtual Extension Ring As signment 0 Turn Off 1 Turn On 1 Turn On 15 09 27 One Touch Key Assignment 0 Turn Off 1 Turn On 1 Turn On 15 14 28 Trunk Name 0 Turn Off 1 Turn On 1 Turn On 14 01 01 29 Automatic Transfer per Trunk 0 Turn Off 1 Turn On 1 Turn On 11 10 06 11 10 07 30 SPD Area No 0 Turn Off 1 Turn On 1 Turn On 11 10 08 ...

Страница 626: ...nd not through PC Programming Use Program 90 39 Virtual Loop Back Port Reset to reset to initial status Input Data Item No Item Input Data Default 01 Virtual Loop Back Reset Reset Dial 1 press Hold Press Hold only to cancel Conditions None Feature Cross Reference PC Programming SL1000 SL1100 ISSUE 3 01 2 604 Program 90 Maintenance Program Program 90 ...

Страница 627: ...r address the Secondary DNS Server address and the Data Roaming Server address Input Data Server Information 1 13 Item No Item Input Data Default 01 Server Address Type 0 IPv4 1 IPv6 0 02 Server Address IPv4 form xxx xxx xxx xxx IPv6 form xxxx xxxx xxxx xxxx xxxx None 03 Port Number 0 65535 0 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 605 Program 90 ...

Страница 628: ...hardware version and firmware version of the DR700 MLT Terminal Input Data Terminal Type 1 3 Not used 4 IP4WW 24TIXH Item No Item Input Data Default 01 Software Version 00 00 00 00 FF FF FF FF 00 00 00 00 02 Hardware Version 00 00 00 00 FF FF FF FF 00 00 00 00 Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 606 Program 90 Maintenance Program Program 90 ...

Страница 629: ... Deleting Terminal License of DR700 to delete the terminal license information delivered to the DR700 terminal Input Data Extension Number Up to four digits SL1000 Up to eight digits SL1100 Item No Item Input Data Default 01 Delete Terminal License Delete Dial 1 press Hold Press Hold only to cancel Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 607 Progr...

Страница 630: ...eleting Terminal License of TCP Interface to delete the terminal license information delivered to the terminal with a TCP interface Input Data License Delete Code 000 000 000 999 999 999 Item No Item Input Data Default 01 Delete Terminal License Delete Dial 1 press Hold Press Hold only to cancel Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 608 Program 90 Maintenance Prog...

Страница 631: ...0 45 Temporary Password Change for Multiline Telephone to change the Temporary Password that is set in the Encryption function Input Data Item No Item Input Data Default 01 Temporary Password Change Re quest 00 00 00 00 FF FF FF FF Change Yes 1 00 00 00 00 Conditions This Program is activated when the Program 10 46 07 set to 1 Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manua...

Страница 632: ...ay Setup to set the system alarm report display Input Data Index Number 01 50 Item No Item Input Data Default 01 System Alarm Display Telephone Up to four digits SL1000 Up to eight digits SL1100 No Setting Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 610 Program 90 Maintenance Program Program 90 ...

Страница 633: ...e exchange of parts that need regular maintenance Input Data Index 1 10 Item No Item Input Data Default 01 Display Name Up to 16 characters Refer below 02 Year 00 99 00 03 Month 01 12 00 04 Day 01 31 00 Index Default 01 No setting 02 Backup battery 03 No setting 04 10 No setting Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 611 Program 90 ...

Страница 634: ...ot through PC Programming Use Program 90 52 System Alarm Save for the system alarm output operation Input Data Item No Item Input Data Default 01 Save All Alarm Reports Print All 1 Yes 02 Save New Alarm Reports Print All 1 Yes Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 612 Program 90 Maintenance Program Program 90 ...

Страница 635: ...y via telephone programming and not through PC Programming Use Program 90 53 System Alarm Clear to clear the system alarm Input Data Item No Item Input Data Default 01 Clear All Alarm Reports All Clear 1 Yes Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 613 Program 90 ...

Страница 636: ...is not reflected from the Web Pro to the logout of all users of the Web Pro who is logging in the system after data is changed in the setting 80 02 PC Pro TCP port Number 1 65535 The port number of TCP of the PC pro gramming is set The port number of new TCP is not reflected from the PCPro to the logout of all users of the PCPro who is log ging in the system after data is changed in the setting 80...

Страница 637: ...y via telephone programming and not through PC Programming Use Program 90 55 Free License Select to validate the Free License Input Data Item No Item Input Data Default 01 Start Free License 0 Stop 1 Start 0 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 615 Program 90 ...

Страница 638: ...to set the NTP Input Data Item No Item Input Data Default 01 NTP Synchronize 0 No 1 Yes 0 02 Server Address IPv4 form xxx xxx xxx xxx IPv6 form xxxx xxxx xxxx xxxx xxxx No Setting Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 616 Program 90 Maintenance Program Program 90 ...

Страница 639: ...g Use Program 90 57 Backup Recovery Data to backup the system data in the Compact Flash memory on the CPU and to make the recovery data Input Data Data ID 1 5 Item No Item Input Data Default 01 Backup Recovery Data Backup Dial 1 press Hold Press Hold only to cancel Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 617 Program 90 ...

Страница 640: ...very Data to select the recovery data stored in the Compact Flash memory of the CPU After this command is executed the system restarts automatically Input Data Data ID 1 5 Item No Item Input Data Default 01 Restore Recovery Data Restore Reset Dial 1 press Hold Press Hold only to cancel Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 618 Program 90 Maintenance Program Progra...

Страница 641: ...amming Use Program 90 59 Delete Recovery Data to select and delete the recovery data stored in the Compact Flash memory of the CPU Input Data Data ID 1 5 Item No Item Input Data Default 01 Delete Recovery Data Delete Dial 1 press Hold Press Hold only to cancel Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 619 Program 90 ...

Страница 642: ...atus information for T1 PRI BRI packages Input Data Slot No 00 16 SL1000 00 09 SL1100 Item No Item Input Data Default 01 Link Status Read Only No Link 0 Link N A No card seen in slot None Conditions This program can be viewed in WebPro or PC Pro V3 0 or higher Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 620 Program 90 Maintenance Program Program 90 ...

Страница 643: ...l IN Description Use Program 90 63 DR700 Control to adjust settings of the DR700 Input Data Item No Item Input Data Default 01 Priority Timer 0 255 80 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 621 Program 90 ...

Страница 644: ...n password Input Data Item No Item Input Data Description Default 01 Password Up to 16 characters Sets the authentication password when the 1st Party CTI application is connected to the system via a NAT router If a pass word is not set the system does not certify it nec i Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 622 Program 90 Maintenance Program Program 90 ...

Страница 645: ...rs No Setting 03 FTP Server Host Name Up to 255 characters Input URL or IP Address of FTP Server Use xxx xxx xxx xxx format in case of IP Address No Setting 04 FTP Server TCP Port 0 65535 21 05 DNS Primary Address 0 0 0 0 126 255 255 254 128 0 0 1 191 255255 254 192 0 0 1 223 255 255 254 0 0 0 0 06 DNS Secondly Ad dress 0 0 0 0 126 255 255 254 128 0 0 1 191 255255 254 192 0 0 1 223 255 255 254 0 0...

Страница 646: ... D RAM data that is saved in F ROM memory D RAM memory Configuration information such as call transfer and Do Not Disturb Input Data Item No Item Input Data Default 01 Interval time 0 255 0 Do not Auto save 1 30 min 2 60 min 3 90 min 255 30 min 127 hr 48 24 hr Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 624 Program 90 Maintenance Program Program 90 ...

Страница 647: ...ut Data Item No Item Input Data Description Default Related Program 01 Adjustment Start Trunk Port Number 001 126 SL1000 001 096 SL1100 This will start the Adjustment of Side Tone for each Analog Trunk Port If it is successful it will change the PRG 81 07 If it is successful it will ask to change it for all Analog Trunk Port If you select to change the Setting All Analog Trunk Port it will change ...

Страница 648: ...oup or other number from which the data is to be copied Destination Number From Enter the first extension trunk group or other number to which the information is to be copied Destination Number To Enter the last extension trunk group or other number to which the information is to be copied If the information is being copied only to one extension trunk group or other number enter the information en...

Страница 649: ...7 Programmable Function Key 15 08 Incoming Virtual Extension Ring Tone Setup 15 09 Virtual Extension Ring Assignment 15 10 Incoming Virtual Extension Ring Tone Order Setup 15 11 Virtual Extension Delayed Ring Assignment 15 12 Conversation Recording Destination for Extension 15 17 CO Message Waiting Indication 15 18 Virtual Extension Key Enhancement Options 20 06 Class of Service for Extension 20 2...

Страница 650: ...opy a multiline terminal Programmable Function Keys copies all keys whether or not they exist on the terminal to which the programming is being copied This may cause confusion when trying to define a key which is already defined but which does not exist on the terminal displays as DUPLICATE DATA It is recommend to either clear these non existent keys or copy only from an extension which has the sa...

Страница 651: ...Delete All Extension Numbers to delete all extension numbers Program 11 02 Program 11 04 However the extension number of the first port is not deleted Input Data Item No Item Input Data Description Default 01 Extension Number Delete Yes 1 Dial 1 Hold key Only press Hold key is canceled Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 629 Program 92 ...

Страница 652: ...V2 0 Changed Including Virtual Extension 01 50 For Department Group Base De partment Group Number 01 32 For DSS DSS Console Number 01 12 Enter the port number from where the data is to be copied 02 Destination Number From Enter the first port number to where the information is to be copied 03 Destination Number To Enter the last port number to where the information is to be copied If the informati...

Страница 653: ...asic Data Setup 15 02 Multi Line Telephone Basic Data Setup 15 03 Single Line Telephone Basic Data Setup 15 06 Trunk Access Map for Extension 15 07 Programmable Function Key 15 08 Incoming Virtual Extension Ring Tone Setup 15 09 Virtual Extension Ring Assignment 15 10 Incoming Virtual Extension Ring Tone Order Setup 15 11 Virtual Extension Delayed Ring Assignment 15 12 Conversation Recording Desti...

Страница 654: ...up Setup 22 06 Normal Incoming Ring Mode 23 02 Call Pickup Group 23 03 Ringing Line Preference 23 04 Ringing Line Preference of Virtual Extension 24 03 Park Hold Group Assignment 24 09 Call Forward Split Settings 26 04 ARS Class of Service 26 07 LCR Cost Center Code Table 31 02 Internal Paging Group Assignment 42 02 Hotel Extension Basic Data Setup 82 14 Handset Headset Gain Setup for Multi Line T...

Страница 655: ...Swap Input Data Extension Number Up to four digits SL1000 Up to eight digits SL1100 Item No Item Input Data Description Default Related Program 01 Password Fixed four digits No setting at default Password required on a per station basis when utilizing the station swap feature No Setting 11 15 12 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 633 Program ...

Страница 656: ...L1000 001 120 SL1100 Program 11 02 Each virtual extension port 01 50 Program 11 04 Each extension group 1 32 Program 11 07 Destination Number From Destination Number To The following table lists Programs that use the Fill Command function Program Number Program Name 11 02 Extension Numbering 11 04 Virtual Extension Numbering 11 07 Extension Department Group Pilot Number Conditions None Feature Cro...

Страница 657: ...sion port 001 128 SL1000 001 120 SL1100 Program 11 02 Each virtual extension port 01 50 Program 11 04 Each extension group 1 32 Program 11 07 Destination Number To The following table lists Programs that use the Delete Command function Program Number Program Name 11 02 Extension Numbering 11 04 Virtual Extension Numbering 11 07 Extension Department Group Pilot Number Conditions None Feature Cross ...

Страница 658: ... for night mode service group Input Data Night Mode Service Group No 1 4 Item No Item Input Data Description Default 01 Day Night mode 1 Mode 1 2 Mode 2 3 Mode 3 4 Mode 4 5 Mode 5 6 Mode 6 7 Mode 7 8 Mode 8 Read Only Indicates current day night mode per night mode service group None Conditions None Feature Cross Reference None SL1000 SL1100 ISSUE 3 01 2 636 Program 93 System Information Program 93...

Страница 659: ...SL1000 Item No Item Input Data Description Default Related Program 01 Set Automatic Transfer to Transfer 0 Disable 1 Enable Read Only Indicates Automatic Trunk Trasfer setting status None 11 10 06 02 Trunk Port Disa ble by Service code 0 Disable 1 Enable Read Only Indicates Trunk Port Disable Busy out status None 11 10 27 Conditions None Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Progra...

Страница 660: ...0 Call Forward Off 1 Call Forward Busy or No answer 2 Call Forward Busy Read Only Indicates Call Forward Busy setting status per extension None 11 11 02 11 11 04 04 Call Forwarding Busy destination 0 9 P R Up to 36 digits Read Only Indicates Call Forward Busy desti nation number set per extension None 11 11 02 11 11 04 05 Call Forwarding Follow Me 0 Disable 1 Enable Read Only Indicates Call Forwar...

Страница 661: ...11 12 14 Forced Intercom Ring ICM Call Type 0 Disable Voice1 1 Enable Signal Read Only Indicates ICM Call Type per exten sion None 11 11 15 11 11 16 15 BGM 0 Disable 1 Enable Read Only Indicates BGM setting status per ex tension None 11 11 18 16 Key Touch Tone 0 Disable 1 Enable Read Only Indicates Key Touch Tone setting status per extension None 11 11 19 17 Dial Block 0 Disable 1 Enable Read Only...

Страница 662: ...SL1100 Redial Last Number 10 Item No Item Input Data Description Default Related Program 01 Redial Data Dial Data 1 9 0 P R Up to 36 digits Read Only Indicates the number stored in Out going call history None 15 02 13 15 02 39 02 Name Up to 12 characters Read Only Indicates the name stored in Outgo ing call hitory None 15 01 01 13 04 02 Conditions None Feature Cross Reference None SL1000 SL1100 IS...

Страница 663: ...matic transfer at De partment Group call 0 Disable 1 Enable Read Only Indicates Automatic transfer setting status per Department Group None 11 11 25 02 Set Delayed transfer at De partment Group call 0 Disable 1 Enable Read Only Indicates Delayed transfer setting status per Department Group None 11 11 28 03 Set DND at De partment Group call 0 Disable 1 Enable Read Only Indicates DND setting status ...

Страница 664: ...MEMO SL1000 SL1100 ISSUE 3 01 2 642 Program 93 System Information Program 93 ...

Страница 665: ...MEMO ISSUE 3 01 SL1000 SL1100 Programming Manual 2 643 ...

Страница 666: ...Programming Manual NEC Corporation ISSUE 3 01 ...

Отзывы: