(2) Connection of the disk array unit with a host system
a) With the host bus adapter or the FC-AL switch connectors of the "LC" type.
Use the available optionally FC cable (NF9320-SJ0xE). Push the connector at either end of
the cable into the FC connector (HPx) of the host bus adapter and either controller (CONT0
or CONT1) until a click is heard. The FC cable has the same connectors at both ends. Either
connector may be connected to the controller.
Pushing any connector excessively may damage the tip and decrease the optical
intensity, which will then cause a malfunction to occur.
Connect the connector at the other end of the FC cable to the host bus adapter
or the FC-AL
switch,
installed at the host system.
<Connection example>
NF2900-SR40E
Host system
Host bus adapter
FC cable (LC-LC cable)
HPx
Similarly, connect the other controller with the other host bus adapter
or the FC-AL switch
installed at the host system.
b) With the host bus adapter or the FC-AL switch connectors of the "SC" type
Use the available optionally FC conversion cable (NF9310-SJ10E). The cable has
different-size connectors at the ends. Push the smaller connector into the FC connector (HPx)
for the host bus adapter of either controller (CONT0 or CONT1) until a click is heard.
Pushing any connector excessively may damage the tip and decrease the optical
intensity, which will then cause a malfunction to occur.
<Connection example>
NF2900-SR40E
Host system
Host bus adapter
SC-SC cable
FC conversion cable
Relay connector
HPx
Connect the other end of the FC conversion cable to the SC-SC cable via the relay connector
provided with the FC conversion cable. Push the connector so that it clicks into place securely.
The connector at an end of the SC-SC cable is the same as that at the other end. Either of the
connectors may be connected to the relay connector.
Connect the connector at the other end of the SC-SC cable to the host bus adapter
or the
FC-AL switch
installed at the host system.
Similarly, connect the other controller with another host bus adapter
or the FC-AL switch
installed at the host system.
Содержание S2900
Страница 8: ...v...
Страница 9: ...vi...
Страница 10: ...vii...
Страница 13: ...x NF2900 SR40E...
Страница 24: ...7...
Страница 43: ...26...
Страница 52: ...35 Sample configuration 1 NF2900 SR40E NF2900 SP02E NF2500 SE42E 16...
Страница 65: ...48 capacity and rotational speed be used together...
Страница 76: ...59 Be careful as this may be hot...
Страница 80: ...63 Note The figure above indicates the addition of NF2900 SC01E...
Страница 133: ...116 DE Location View DE00 DE01 DE05 DE09 DE0 DE0 DE04 DE08 DE03 DE07 DE0 DE0 DE02 DE06 DE0 DE0...
Страница 134: ...117 1 2 5 Network Property Select 4 Configuration 7 Network Property to set the following items...