Chapter 3 Appendix
CPU1_DIMM1 Correctable Error
CPU1_DIMM2 Correctable Error
CPU1_DIMM3 Correctable Error
CPU1_DIMM4 Correctable Error
CPU1_DIMM5 Correctable Error
CPU1_DIMM6 Correctable Error
CPU2_DIMM1 Correctable Error
CPU2_DIMM2 Correctable Error
CPU2_DIMM3 Correctable Error
CPU2_DIMM4 Correctable Error
CPU2_DIMM5 Correctable Error
CPU2_DIMM6 Correctable Error
[Description]
Indicates that correctable error frequently occurred on DIMM.
You can continue to run the system.
[Recommended action]
Restart the server.
If it does not solve your problem, check installation status of DIMM.
If it does not solve your problem, remove DIMM and install it again.
If it does not resolve your problem, contact your sales representative.
Tips
•
You can identify the DIMM on which a correctable error frequently occurred
by viewing OS system event log or IPMI system event log.
Memory DIMM Sparing Fail-over on CPU1
Memory DIMM Sparing Fail-over on CPU2
[Description]
A correctable error frequently occurred on DIMM connected with CPUx, but Memory Sparing feature failed
over to standby memory. x denotes CPU number.
You can continue to run the system.
[Recommended action]
Restart the server.
If it does not solve your problem, check installation status of DIMM.
If it does not solve your problem, remove DIMM and install it again.
If it does not resolve your problem, contact your sales representative.
Tips
•
You can identify the DIMM on which a correctable error frequently occurred
by viewing OS system event log or IPMI system event log.