Installation Guide
QX-S6600 Series Ethernet Switches
10-10
Caution:
Minimum bend radius of 40G QSFP+ Copper cable is 50mm. When not securing minimum bend radius of a
cable, there is damage of a cable or a possibility that performance deterioration forms. Don't bend a cable
below the minimum bend radius. Please refer to QSFP+ on Figure 10-4 (the right side) for a figure of the
minimum bend radius of QSFP+ copper wire cable.
10G SFP+ side minimum bend radius of 40G QSFP+/10G SFP+ Copper cable is 35mm. 40G QSFP+ side
minimum bend radius is 50mm. When not securing minimum bend radius of a cable, there is damage of a
cable or a possibility that performance deterioration forms. Don't bend a cable below the minimum bend
radius. Please refer to Figure 10-3 for 40G QSFP+/10G*4 SFP+ change copper wire cable. Please refer to
Figure 10-4 for a figure of the minimum bend radius of 40G QSFP+/10G*4 SFP+ change copper wire cable.
10.1.6 1/10G Base-T autosensing Ethernet port
QX-S6648XT-6Q has 1/10G Base-T autosensing Ethernet ports.
Table 10-10
1/10G Base-T autosensing Ethernet port specifications
Item
Specification
Connector type
RJ-45
Port transmission rate
1/10 Gbps,/full duplex, MDI/MDI-X autosensing
Transmission medium and max
transmission distance
55 m (180.45 ft) over category-6 unshielded twisted pair cable
100 m (328.08 ft) over category-6 shielded twisted pair cable
100 m (328.08 ft) over category-6A or above twisted pair cable
Compatible standards
IEEE 802.3ab
IEEE 802.3an
To avoid interference between cables, layer cables as follows:
Use category-6A or above cables and connectors.
Do not bundle cables in their first 20 m.
Separate power cords and twisted pair cables at and around the distribution frame.
For ports adjacent to one another on the device, the peer ports on the distribution
frame are preferably not adjacent, for example:
1) If the device connects to one distribution frame, connect port 1 on the device to port 1
on the distribution frame, port 2 on the device to port 3 on the distribution frame, and
port 3 on the device to port 5 on the distribution frame.
2) If the device connects to two distribution frames, connect port 1 on the device to port 1