E – 46
16. COLOR TEMP SELECT
Function
The external control equipment changes the COLOR TEMP of the PlasmaSync 5000W.
Transmission Data
DFH 80H
60H
00H
01H
DATA00 CKS
DATA00
00H: 1
01H: 2
02H: 3
03H: PRO
ACK
7FH
60H
80H
00H
01H
DATA00
CKS
DATA00:
00H: 1
01H: 2
02H: 3
03H: PRO
NOTE: Set so that at the selection of 1, 2, or 3 of COLOR TEMP change of the following R/G/B GAIN data cannot be
accepted. (This must be operated in the same way as OSD menu.)
17. RED Gain Data
Function
The external control equipment changes the RED Gain Data of the PlasmaSync 5000W.
Transmission Data
DFH 80H
60H
7FH
04H
DATA00 to DATA03 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: RED Gain Flag
01H
DATA02: RED Gain 1 (Bias)
F0H: -16
FFH: -1
00H: 0
10H: +16
DATA03:RED Gain 2 (Drive)
F0H: -16
FFH: -1
00H: 0
10H: +16
ACK
7FH
60H
80H
7FH
02H
DATA00
DATA01
CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: RED Gain Flag
01H