465
CHAPTER 19 SERIAL INTERFACE CHANNEL 2
When the internal clock is used as the serial clock in the 3-wire serial I/O mode, set BRGC as described below.
BRGC setting is not required if an external serial clock is used.
(i) When the baud rate generator is not used:
Select a serial clock frequency with TPS0 to TPS3.
Be sure then to set MDL0 to MDL3 to 1,1,1,1.
The serial clock frequency is 1/2 the source clock frequency of the 5-bit counter.
(ii) When the baud rate generator is used:
Select a serial clock frequency with TPS0 to TPS3.
Be sure then to set MDL0 to MDL3 to 1,1,1,1.
The serial clock frequency is calculated by the following formula:
Serial clock frequency = [H
z
]
Remarks 1. f
X
:
Main system clock oscillation frequency
2. f
XX
:
Main system clock frequency (f
X
or f
X
/2)
3. n
:
Value set in TPS0 to TPS3 (1
≤
n
≤
11)
4. k
:
Value set in MDL0 to MDL3 (0
≤
k
≤
14)
f
XX
2
n
x (k + 16)