Base Module
855-900547-200 2-30
2.4.5.
SP Command Console
If SP Command is chosen from the iSP Main Menu, SP Command Console appears on the
console screen.
To return from SP Command Console to the Main Menu, enter “^B” (press the B key while
holding down CTRL).
Some SP commands are only valid on the master iSP.
(Screen Example)
Description
No.
iSP MAIN MENU
0) OS(BIOS) serial console of partition#0 (INITIALIZING )
1) OS(BIOS) serial console of partition#1 (RUNNING )
2) OS(BIOS) serial console of partition#2 (STOPPED )
3) OS(BIOS) serial console of partition#3 (FAULT )
4) OS(BIOS) serial console of partition#4 (POWER OFF )
5) OS(BIOS) serial console of partition#5 (RUNNING )
6) OS(BIOS) serial console of partition#6 (NOT CONFIGURED)
7) OS(BIOS) serial console of partition#7 (NOT CONFIGURED)
V) Virtual System Operator Panel
S) iSP commands
E) Exit
DISCONNECTALL) disconnect all console connections
iSPyz>
S
<ENTER>
(a)
:
:
:
:
:
(b)
<CTRL>+<B>
(c)
(Description)
Description
No.
Description
(a)
SP Command Console appears if S is entered at this prompt.
(b)
You can enter SP commands and monitor SP messages until ^B is entered.
(c)
CTRL+B quits SP Command Console. The screen returns to the Main Menu.
Содержание NX7700i/5040H-32
Страница 19: ...xviii 420 422 ...
Страница 26: ...xxv 5 2 DVD ROM CD ROM 5 1 5 3 Digital Audio Tape 5 1 5 4 Cleaning 5 2 5 5 Notes on Installation 5 3 ...
Страница 41: ...Base Module 855 900547 200 2 5 Figure 2 5 PCIBAY Numbers in the Main Cabinet PCIBAY0 PCIBAY2 PCIBAY3 PCIBAY1 ...
Страница 50: ...Base Module 855 900547 200 2 14 Figure 2 13 Loading and Unloading DAT DAT slot Main Cabinet I O MODULE ...
Страница 170: ...Notes on Handling 855 900547 200 5 4 Memo ...