Base Module
855-900547-200
2-59
cmd arg1 arg2 arg3 arg4
Description
check
-
-
-
-
This command is used to check the current
system configuration focusing on the
following points:
•
Presence of units with unspecified
locations
•
Presence of DISABLED components
•
Presence of INVISIBLE units
This command is always valid without regard
to the current system state.
The “DISABLE.” components are not the
target of this command.
clear row
xyy
|
dir
xzz
-
-
-
Use this command to clear the ROW or
Directory memory bit error counters.
x
is a physical CELL number (0-7).
yy
is a ROW number (00-15) within a CELL,
which must be specified with a 2-digit
number.
zz
is a Directory number (00-15) within a
CELL, which must be specified with a 2-digit
number.
This command clears the 3 counters - the
single-bit error counter that counts errors for
every DIMM and the multibit error counter
that counts errors for every ROW - at a time,
along with the page deallocation entry table.
Argument dir
xzz
is only supported on the
32Way(H) model.
This command is always valid without regard
to the current system state.
bio iox
y
[iox
z
]
-
-
Use this command to specify the BIO to be
used on the IOX (PCI Bay) that is attached to
a partition.
For partitions with duplicated BIOs, use
<arg2> to specify the IOX (PCI Bay) with a
secondary BIO. If <arg2> is omitted, the
secondary BIO is regarded to be
non-existent.
The IOX (PCI Bay) specified in this
command must be attached to a partition.
This command is valid only if the partition is
inactive.
It is not supported on the ISPF.
scsi_sp
lit
pcib
x
on|off
-
-
Use this command to specify the SCSI split
mode (split mode ON or OFF) for PCI Bay
No.
x
.
Split mode is set to OFF by default.
Split mode setting can be changed when the
partition to which the pertinent PCI Bay
belongs is inactive or the power to the PCI
Bay is left off. Split mode setting cannot be
changed while the partition is booting up or
shutting down.
Содержание NX7700i/5040H-32
Страница 19: ...xviii 420 422 ...