CHAPTER 4 CIRCUIT CARD INFORMATION
PN-DAIC (DAI)
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and
, the setting of the switch varies with the system concerned.
NOTE:
When the power is on, flip MB switch to ON (UP position) before plugging/unplugging
the circuit card.
SW3 (DIP SW)
1
Set the equalizer according to the
cable length between the system
and the CSU.
OFF
2
OFF
3
OFF
4
ON
When mounting this card on
Remote Site
OFF
When mounting this card on Main
Site
SWITCH
NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
1 2 3 4
ON
ON
SW
-1
SW
-2
SW
-3
CABLE
LENGTH
ON
ON
ON
0 - 40 m
(0 - 131.2 ft.)
ON
ON
OFF
40 - 80 m
(131.2 - 262.5 ft.)
ON
OFF
ON
80 - 120 m
(262.5 - 394 ft.)
ON
OFF OFF
120 - 160 m
(394 - 525 ft.)
OFF
ON
ON
160 - 200 m
(525 - 656 ft.)
OFF OFF OFF
Signal is not sent.
ON
ON