ND-45383 (E)
CHAPTER 3
Page 89
Revision CD 1.0
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
Note 4:
Switch setting of m-bit (4 Kbps) data link system of 24 Multi Frame Format **
SW2-3
BOS (Bit Oriented Signals) System
:
ON
MOS (Message Oriented Signals) System
:
OFF
**This switch setting is valid only when SW2-2 has been set to OFF. When SW2-2 has been set to ON, SW2-
3 must be set to OFF.
Note 5:
Switch setting specifying the Equalizer
(The distance between the DRU and the PCM MUX)
SW1-1
SW1-2
SW1-3
0 ~ 266 feet
:
ON
ON
ON
266 ~ 534 feet
:
ON
ON
OFF
534 ~ 800 feet
:
ON
OFF
ON
800 ~ 1066 feet
:
ON
OFF
OFF
1066 ~ 1310 feet
:
OFF
ON
ON
For in-premise direct installation
:
OFF
ON
ON
Note 6:
Switch setting for 23ELC/11DLC + 1ELC Mode
SW1-5
23ELC Mode
:
ON
11DLC + 1ELC Mode
:
OFF
Note 7:
Switch setting for transmission line code (ZCS)
SW1-6
B7 Stuffing
:
ON
B8ZS
:
OFF