![NEC NEAX 2400 ICS Скачать руководство пользователя страница 132](http://html1.mh-extra.com/html/nec/neax-2400-ics/neax-2400-ics_manual_3887361132.webp)
ND-45383 (E)
CHAPTER 5
Page 123
Revision CD 1.0
(4) Message Detail Data
1: XX XX
Kind of fault
01: Frame loss PCM down (Minor)
02: Bit error more than 10
-6
03: Slip detected (Minor)
05: Signal link down detected
06: Multiframe loss (Minor)
11: Frame loss PCM down (Major)
12: Bit error 10
-4
13: Slip detected (Major)
14: Remote office alarm detected
16: Multiframe loss (Major)
17: Frame loss PCM down (Continuous)
18: Multiframe loss (Continuous)
Accommodated location of detected DLI card
(Refer to paragraph 2.1.1)
MG: Module Group
U:
Unit
G:
Group
MG
U
G