75
Chapter 3 Features of Disk Array
Controller
This chapter describes the features of the disk array controller.
1. Rebuild
If a HDD fails, the rebuild feature can recover the data on the failed HDD. The access lamp on the failed
HDD lights amber. The rebuild can be applied to redundant virtual disks in RAID1 after the failed HDD is
replaced. While rebuilding, the access lamp on the replaced HDD flashes.
1-1 Manual Rebuild
The manual rebuild can be performed by using MegaRAID Storage Manager
TM
(called MSM hereafter), which
is the management utility of the disk array controller. Select a HDD and start the rebuild manually.
For the detailed operation, refer to the "MegaRAID Storage Manager
User's Guide" on the NEC
EXPRESSBUILDER CD-ROM that comes with the server.
1-2 Auto Rebuild
The disk array controller can automatically start the rebuild without using a utility such as MSM.
The auto rebuild includes:
Hot-swap rebuild
When the failed HDD is hot-swapped with a new HDD, the auto rebuild is automatically performed.
Notice
Note the following for the rebuild:
The HDD used for rebuild should have the same capacity, rotation speed, and
standard as the failed HDD.
During rebuild, the responsiveness of the server decreases due to high load.
During rebuild, do not shutdown or reboot the server. If the server is shutdown
accidentally due to power interruption, turn on the power as soon as possible. The
rebuild is automatically restarted.
The interval from the removal of the failed HDD to the installation of a new HDD
should be 60 sec or longer.
If the hot-swap rebuild does not work, perform the manual rebuild.
When the failed HDD is removed in a RAID1 configuration, the data redundancy is
lost. Replace with a new HDD as soon as possible and perform the rebuild process.
Содержание N8403-019
Страница 27: ...7 4 3 内部接続ケーブル 1本 4 4 ディスクアレイコントローラ取り付けネジ 3個 ...
Страница 40: ...20 8 バックプレーンボードを取り付けます 1 本体装置にハードディスクドライブが実装されている場合は 取り外します 2 フロントカバーの4箇所のネジを外します 3 フロントカバーを矢印方向に垂直に上げ取り外します ...
Страница 41: ...21 4 既存バックプレーンボードがある場合は 3箇所のネジを外し 既存バックプレーンボードを取 り外します 5 新規バックプレーンを 取り外した3箇所のネジを利用し取り付けます ...
Страница 42: ...22 6 フロントカバーを コネクタの勘合に気を付けながら取り付けます 7 フロントカバーの両サイドのネジを取り付けます ...
Страница 44: ...24 ケーブルを外す場合は ケーブルのロックピンを解除するため下図の場所を押しながら引き抜いて ください 10 リアカバーを取り付けます ...
Страница 106: ...86 7 Install the rear cover ...
Страница 111: ...91 When the adapter is selected in Adapter Selection the WebBIOS top menu appears ...
Страница 113: ...93 Click Next to see the detailed settings of this controller ...
Страница 124: ...104 Custom Configuration Use this menu to define several physical drives PD as a disk group DG ...
Страница 137: ...117 2 Select VD 0 already constructed in Virtual Drives 3 The setting menu for VD 0 is displayed ...