114
4-2 Manual Rebuild
Described below is the rebuild procedure when one of the HDD fails in a RAID1 virtual disk configured with
two HDD
‟s.Replace the failed HDD with a new one after turning off the power of the server. The Auto Rebuild
feature is disabled for non-hot-swap replacement. Use the Manual Rebuild feature to recover the virtual disk
as described below:
1.
Start WebBIOS.
Make sure that the status for the replaced HDD is indicated as "UNCONF GOOD" in the right frame
of the top menu.
2
3
2.
Make sure that the HDD that has been installed in slot 1 is missing.
3.
Select "PD2" (newly connected HDD) in [Physical Drives].
The properties for the physical drive are displayed.
4.
Select "Make Global HSP" from the lower right of the screen, and then click [Go] at the lower center
of the screen.
Содержание N8403-019
Страница 27: ...7 4 3 内部接続ケーブル 1本 4 4 ディスクアレイコントローラ取り付けネジ 3個 ...
Страница 40: ...20 8 バックプレーンボードを取り付けます 1 本体装置にハードディスクドライブが実装されている場合は 取り外します 2 フロントカバーの4箇所のネジを外します 3 フロントカバーを矢印方向に垂直に上げ取り外します ...
Страница 41: ...21 4 既存バックプレーンボードがある場合は 3箇所のネジを外し 既存バックプレーンボードを取 り外します 5 新規バックプレーンを 取り外した3箇所のネジを利用し取り付けます ...
Страница 42: ...22 6 フロントカバーを コネクタの勘合に気を付けながら取り付けます 7 フロントカバーの両サイドのネジを取り付けます ...
Страница 44: ...24 ケーブルを外す場合は ケーブルのロックピンを解除するため下図の場所を押しながら引き抜いて ください 10 リアカバーを取り付けます ...
Страница 106: ...86 7 Install the rear cover ...
Страница 111: ...91 When the adapter is selected in Adapter Selection the WebBIOS top menu appears ...
Страница 113: ...93 Click Next to see the detailed settings of this controller ...
Страница 124: ...104 Custom Configuration Use this menu to define several physical drives PD as a disk group DG ...
Страница 137: ...117 2 Select VD 0 already constructed in Virtual Drives 3 The setting menu for VD 0 is displayed ...