background image

1. Installing Internal Optional Devices 

 

Express5800/R120d-2M  User’s Guide 

47 

Chapter 2  Preparations 

6.  Remove Top Cover. 

Refer to 

Chapter 2

 (

1.6 Removing Top Cover

). 

7.  Remove PCI riser card. 

Refer to 

Chapter 2

 (

1.7 Removing PCI Riser Card

). 

8.  Remove the support bar. 

Refer to 

Chapter 2

 (1.8Removing Support Bar). 

9.  Depending on the components to be installed or removed, follow the procedure in order. 

Refer to 

Chapter 2

 (

1.10 Internal Flash Memory (N8115-07)

) to (

1.20 Use of Internal hard disk 

drives in the RAID

 System).

 

10.  Install the support bar. 

Refer to 

Chapter 2

 (

1.22 Installing Support Bar

). 

11.  Install PCI riser card. 

Refer to 

Chapter 2

 (

1.23 Installing PCI Riser Card

). 

12.  Attach Top Cover. 

Refer to 

Chapter 2

 (

1.21 Installing Top Cover

). 

 

13.  Mount the server onto the rack. 

Refer to 

Chapter 2

 (

2.1.2

 

Installing the server to the rack or removing it from the rack

 (1) 

Installation

). 

 

14.  Install hard disk drives. 

Refer to 

Chapter 2

 (

1.25 Hard Disk Drive

). 

 

15.  Install power supply units 

Refer to 

Chapter 2

 (

1.26 Power Supply Unit

). 

 

16.  Attach Front Bezel. 

Refer to 

Chapter 2

 (

1.27 Installing the Front Bezel

). 

 

This is the end of the installation or removal procedures for internal optional devices.   
Continue the setup with reference to 

Chapter 2 (2.2 Connection)

 

Содержание N8100-1793F

Страница 1: ...800 Series 10 021 02 101 01 April 2012 First Edition NEC Corporation 2012 Express5800 R120d 2M EXP292 User s Guide Model Number N8100 1793F Chapter 1 General Description Chapter 2 Preparations Chapter...

Страница 2: ...ons connection of peripheral devices and ideal location for this server Chapter 3 Setting Up Your Server System BIOS configurations and summary of EXPRESSBUILDER Chapter 4 Appendix Specifications and...

Страница 3: ...4 Power supply and power cord use 15 Installation relocation storage and connection 16 Cleaning and working with internal devices 17 During operation 18 Warning labels 19 External view 19 Handling pre...

Страница 4: ...nstallation 66 1 13 6 Replacement Removal 67 1 13 7 Using Memory RAS Feature 68 1 14 Battery for RAID Controller 76 1 14 1 Handling precautions 76 1 14 2 Installing Battery 76 1 14 3 Removal 77 1 15 L...

Страница 5: ...122 Setup 123 1 Turning on the Server 124 1 1 POST 125 1 1 1 POST sequence 125 1 1 2 POST error messages 126 2 System BIOS Setup 127 2 1 Overview 127 2 2 Starting and Exiting SETUP Utility 127 2 2 1 S...

Страница 6: ...e Indicates items that must be confirmed when handling the server or operating software Tips Indicates information that is helpful to keep in mind when using this server Optical disk drives This serve...

Страница 7: ...ows Server 2003 R2 Standard Windows Server 2003 R2 Enterprise Windows Server 2003 2 Windows Server 2003 Standard Windows Server 2003 Enterprise Windows 7 Windows 7 Professional 64 bit x64 Edition Wind...

Страница 8: ...or trademarks of Adaptec Inc of the United States LSI and the LSI logo design are trademarks or registered trademarks of LSI Corporation Adobe the Adobe logo and Acrobat are trademarks of Adobe System...

Страница 9: ...que de la classe A est conforme la norme NMB 003 du Canada CE Australia and New Zealand Statement This is a Class A product In domestic environment this product may cause radio interference in which c...

Страница 10: ...omissions please contact your retailer 5 Regardless of these 4 items NEC Corporation does not take responsibility for effects resulting from operations 6 The sample values used in this document are n...

Страница 11: ...WARNING or CAUTION is used to indicate a degree of danger These terms are defined as follows WARNING Indicates there is a risk of death or serious personal injury CAUTION Indicates there is a risk of...

Страница 12: ...shock or fire may be caused Do not touch the server with wet hand Otherwise an electric shock may be caused Do not touch the component specified by this symbol Otherwise an electric shock or burn may...

Страница 13: ...shock Use a rack that conforms to the designated standard This server can be mounted onto a 19 inch rack that conforms to EIA standards Do not mount the server onto any rack that does not conform to E...

Страница 14: ...ponents such as the door or rails When installing the door make sure that both upper and lower hinge pins are held in place Incomplete attachment may cause components to fall off as well as personal i...

Страница 15: ...ngle outlet by using extension cords The electric current exceeding the rated flow overheats the outlet which may cause a fire Insert the power plug into the outlet as far as it goes Heat generation r...

Страница 16: ...ied Do not install the server in the following places or any place other than specified in this User s Guide Failure to follow this instruction may cause a fire A dusty place A humid place such as nea...

Страница 17: ...the server with loose cable connections Do not use any damaged cable Cleaning and working with internal devices WARNING Do not disassemble repair or alter the server Never attempt to disassemble repa...

Страница 18: ...rver during thunderstorms Do not touch any part of the server including the cables when a thunderstorm is approaching Also do not connect or disconnect any devices There may be a risk of electric shoc...

Страница 19: ...tial hazards This label is either attached or printed on the component to draw attention from users to potential hazards involved in handling the server Do not remove or black out this label and keep...

Страница 20: ...rive In the following cases check and adjust the system clock before operation After transportation After storage After the server is used following a period of disuse in which storage conditions did...

Страница 21: ...from reflecting bright lights and to make the display contents easy to see Working without adjusting the display to a comfortable angle makes it difficult for you to maintain a proper posture and you...

Страница 22: ...e features of this server and the name of each part 1 Introduction 2 Accessories Verify the condition of your server s accessories 3 Standard Features This section describes the server s features and...

Страница 23: ...processor NEC s latest technology and architectures realize high power and high speed operation that cannot be matched by existing servers The server is designed with consideration of not only reliabi...

Страница 24: ...p device x4 1 Documents are stored in EXPRESSBUILDER Adobe Reader is required to read the documents so make sure you have it installed in your PC Make sure you have all accessories and inspect them If...

Страница 25: ...3L 1600 supported 2 High speed disk access SATA SAS 6Gbps supported High speed 1000BASE T 100BASE TX 10BASE T 2 ports interface 1Gbps 100Mbps 10Mbps supported High reliability Processor throttle ring...

Страница 26: ...ility PCI Express 3 0 x8 lanes 3 slots Full Height PCI Express 3 0 x4 lanes 2 slots Low profile PCI Express 3 0 x8 lanes 1 slot dedicated to RAID Controller PCI Express 3 0 x8 lanes 1 slot dedicated t...

Страница 27: ...BMC conforming to IPMI v2 0 Self diagnosis Power On Self Test POST Test and Diagnosis T D utility Easy setup EXPRESSBUILDER setup utility BIOS Setup utility SETUP Maintenance features Off line Tools...

Страница 28: ...m environment Monitors temperatures fans voltage power supply and others Temperature Monitors the temperature inside of the chassis Fan Monitors the fans Voltage Monitors the voltage inside of the cha...

Страница 29: ...Version Management Use of NEC ESMPRO Manager and ExpressUpdate Agent allows you to manage versions of firmware and software as well as update them by applying update packages This feature automatical...

Страница 30: ...zel Lock Key that is used to lock Front Bezel 6 Unit ID UID LED This LED turns on when UID Switch is pressed Commands from the software also cause it to turn on or flash See page 39 3 LINK ACT LED Thi...

Страница 31: ...Switch LED The switch to turn on and off UID LED Pressing the switch once turns on UID LED and pressing again turns off the LED Commands from the software also cause it to turn on or flash See page 39...

Страница 32: ...ility LAN connector 1 can also be used as the management LAN port However sharing port is not recommended from the point of performance and security because LAN port 1 may receive both data 11 SPEED L...

Страница 33: ...4 Names and Functions of Parts Express5800 R120d 2M User s Guide 33 Chapter 1 General Description 4 4 External View 1 Top Cover front 2 Release Button 3 Top cover rear...

Страница 34: ...tional 8 FAN3F optional 9 FAN4F optional 10 FAN5F optional FAN1 to FAN4 are factory installed FAN5 is required in 2 CPU configuration FAN6 to FAN10 are required in redundant configuration 1 CPU config...

Страница 35: ...and Functions of Parts Express5800 R120d 2M User s Guide 35 Chapter 1 General Description 4 6 Motherboard 27 23 8 1 28 25 18 13 24 17 16 13 15 14 13 12 11 10 9 26 8 2 7 6 5 4 3 2 1 1 2 1 2 2 18 19 21...

Страница 36: ...odule USB backup device 15 HDD BP connector 16 Connector for option COM Connect an additional RS 232C connector kit N8117 01A to use this port as a serial port B 17 SPI Mezzanine connector EXPRESSSCOP...

Страница 37: ...status of the server The following table lists POWER LED patterns and their explanation POWER LED pattern Explanation On green The server is normally powered on On amber BMC is being initialized When...

Страница 38: ...sted e g when DUMP Switch is pressed Note It remains green if the dump is caused by software Wait until the memory dump is completed On amber A temperature alarm was detected Check the internal fan fo...

Страница 39: ...tact your sales representative Flashing green and amber alternately only when RAID system is configured Rebuild is in progress Off Hard disk drive is halted 4 7 5 Optical Disk Access LED The LED for o...

Страница 40: ...Contact your sales representative Flashing green and amber alternately only when RAID system is configured Rebuild is in progress When the failed hard disk drive is replaced rebuild process starts aut...

Страница 41: ...g green The server is accessing network Off The server is disconnected from network SPEED LED 1 2 M This LED indicates which network interface is used Two onboard LANs 1 2 support 1000BASE T 100BASE T...

Страница 42: ...patterns and their explanation AC POWER LED pattern Explanation Solution On green The server is powered on Flashing green The power cable is connected and AC power is supplied Cold Redundant feature i...

Страница 43: ...This chapter describes preparations for using this server 1 Installing Internal Optional Devices You can skip this section if you did not purchase any optional devices 2 Location and Connection You mu...

Страница 44: ...and remove optional devices properly and safely WARNING Be sure to observe the following precautions to use the server safety Failure to observe the precautions may cause death or serious injury For...

Страница 45: ...y periodically touching a metal surface while working on the components Select a suitable work space Work with the server on the anti static or concrete floor If you work with the server on a carpet w...

Страница 46: ...atures Do not get your fingers caught when installing components 1 If the server is mounted on a rack use the UID switch to identify the target server Refer to Chapter 2 1 4 Confirming Servers UID Swi...

Страница 47: ...all the support bar Refer to Chapter 2 1 22 Installing Support Bar 11 Install PCI riser card Refer to Chapter 2 1 23 Installing PCI Riser Card 12 Attach Top Cover Refer to Chapter 2 1 21 Installing To...

Страница 48: ...Using UID Unit ID Switch helps you to identify the target server When the server is working or before you turn the server off or disconnect a cable from the server be sure to identify the target serv...

Страница 49: ...low Remove the front bezel when pressing switches such as POWER switch or removing the top cover 1 Insert the attached Bezel Lock Key into the key slot and turn the key to the front bezel side while p...

Страница 50: ...Additional HDD cage PCI card RAID Controller Battery for RAID Controller 1 Refer to steps 1 to 5 in Chapter 2 1 3 Overview of Installation and Removal for preparations 2 Slide Top Cover front toward...

Страница 51: ...following component or changing internal cable connection LAN riser card DIMM Processor CPU TPM module Internal Flash Memory Additional HDD cage PCI card RAID Controller Battery for RAID Controller 1...

Страница 52: ...when installing or removing the following component or changing internal cable connection DIMM Processor CPU Additional HDD cage PCI card Battery for RAID Controller 1 Refer to steps 1 to 7 in Chapter...

Страница 53: ...e following component or changing internal cable connection DIMM Processor CPU 2 5 inch additional HDD cage 1 Refer to steps 1 to 7 in Chapter 2 1 3 Overview of Installation and Removal for preparatio...

Страница 54: ...ash Memory optional 1 10 1 Installation Install Internal Flash Memory in the following procedure 1 Refer to steps 1 to 7 in Chapter 2 1 3 Overview of Installation and Removal for preparations 2 Attach...

Страница 55: ...re for installing optional TPM Kit 1 11 1 Installation Install TPM Kit in the following procedure Refer to steps 1 to 7 in Chapter 2 1 3 Overview of Installation and Removal for preparations Install T...

Страница 56: ...of the server due to failures or damage resulted from installing such a processor will be charged Tips After adding the processor Windows may record the event log to System category of Event Viewer b...

Страница 57: ...s 6 Push down the socket lever marked with once to unlatch it from the hook then slowly open the lever until it stops 7 Lift the plate Important Do not touch the socket contacts 8 Put the additional p...

Страница 58: ...ion Note Insert the processor while aligning the notch on the processor with the key on the CPU socket Bring down the processor straight without tilting or sliding it in the socket 9 Lightly push the...

Страница 59: ...probably causes the heat sink not to be level The CPU is not positioned correctly All screws are not completely tightened Do not move the secured heat sink 14 When additional processor is installed yo...

Страница 60: ...remove the heat sink from the processor first turn the heat sink to the left and right lightly to make sure that the heat sink can be apart from the processor Removing the heat sink with it adhering...

Страница 61: ...tion 1 13 1 Maximum supported memory size The maximum available memory size on the server depends on the architecture and OS specs List of maximum memory sizes OS The maximum memory size supported on...

Страница 62: ...Memory Kit N8102 476 6GB DDR3 1600 REG Memory Kit N8102 477 12GB DDR3 1600 REG Memory Kit N8102 499 24GB DDR3 1600 REG Memory Kit N8102 500 48GB DDR3 1600 REG Memory Kit DIMMs installed on N8101 546F...

Страница 63: ...B DDR3 1600 REG Memory Kit 1333 MHz 1066 MHz 1600 MHz 1066 MHz N8102 469F 8GB DDR3 1600 REG Memory Kit N8102 470F 16GB DDR3 1600 REG Memory Kit N8102 471F 32GB DDR3 1600 REG Memory Kit N8102 440F 64GB...

Страница 64: ...al memory board See the table below for RAS features supported by additiional memory board List of features supported by additiional memory board N code Product name Standard feature x4 SDDC Memory Mi...

Страница 65: ...See the table below to find allowable combination of DIMMs and install DIMMs starting from the largest capacity and from the smallest slot number N code N8102 435F 468F 469F 470F 471F 440F 472 473 47...

Страница 66: ...erminal part 4 Continue to install or remove internal optional devices mount and connect the server and turn it on 5 Confirm that no error messages are displayed in POST screen If any error messages a...

Страница 67: ...he DIMM socket where the defective DIMM is installed Take the steps below after replacing or removing DIMMs 1 Confirm that no error messages are displayed on POST If any error message is displayed ref...

Страница 68: ...tic correction of memory error multi bit error Note Refer to List of features supported by additiional memory board in 1 13 3 Memory RAS Feature before using memory RAS feature Only the features that...

Страница 69: ...nnels 0 and 1 or channels 2 and 3 To use Memory Mirroring feature install N8102 472 473 474 475 additional memory board two DIMMs of same model DIMMs to be installed in mirror set must have same capac...

Страница 70: ...ing parameter Advanced Memory Configuration Memory Information CPUx_DIMMx Status Installation order depends on CPU configuration See the figure below Memory Mirroring cannot be configured in the follo...

Страница 71: ...tion With this feature a single device can detect and correct one to eight bit error Note Memory LockStep feature uses channels 0 and 1 or channels 2 and 3 To use Memory LockStep feature install N8102...

Страница 72: ...re below Memory Lock Step cannot be configured in the following cases Memory Lock Step between memory channels of different memory controllers CPU Memory Lock Step within the same memory channel Notes...

Страница 73: ...ng feature install N8102 476 477 499 500 additional memory board three DIMMs of same model Tips The operating system recognizes the DIMMs as those with capacities less than the actual physical capacit...

Страница 74: ...splayed in Sparing Refer to Chapter 2 1 System BIOS in Maintenance Guide run SETUP change parameters as shown below save the settings and exit from SETUP Advanced Memory Configuration Memory RAS Mode...

Страница 75: ...u additionally install DIMMs that unable to configure Memory Sparing When you remove DIMMs that takes down Memory Sparing 1CPU 2CPU 3 3 3 4 4 4 2 2 2 1 1 1 5 5 5 7 7 7 3 3 3 1 1 1 6 6 6 8 8 8 4 4 4 2...

Страница 76: ...tery dedicated to the RAID Controller you are using The battery is a very delicate electronic device Before installation touch the metal frame part of the server to discharge the static electricity fr...

Страница 77: ...racket 6 Remove the two screws from RAID Controller and remove PCI bracket 7 Install the RAID Controller bracket to RAID Controller using two screws you have removed in Step 6 8 Install RAID Controlle...

Страница 78: ...install the LAN Riser Card Important You must avoid static electricity to work with the procedure below For details refer to Chapter 2 1 2 Anti static Measures 1 15 1 Installation Follow steps below...

Страница 79: ...ard slot and insert the card securely 6 Secure the bracket of LAN Riser Card with two screws you have removed in step 4 7 Install the port cover provided with LAN Riser Card 1 15 2 Removal Remove LAN...

Страница 80: ...e slot numbers assigned to the slots of standard cooling fans and optional cooling fans 1 Slots to install additional fan unit when additional CPU board is installed 2 Slots to install redundant fan u...

Страница 81: ...fan unit straight into slot When the fan unit is inserted to the end it is locked with clicking sound Note Keep the removed fan cover for future use 2 Additional for redundant configuration 1 Refer t...

Страница 82: ...while the system is powered on and running You can identify the failing fan by using the management tool such as EXPRESSSCOPE Engine 3 While the system is powered on or running the LED of failed fan u...

Страница 83: ...he PCI devices of the same type including onboard PCI device may be recognized in different order from that described above depending on OS or RAID Configuration Utility Check the slot location of PCI...

Страница 84: ...ist supported boards and slots available for them For details of the features of each board refer to the manual supplied with it Tips Different boards mounted on the same bus operate at the lower freq...

Страница 85: ...battery N8103 162 can be mounted Up to one internal and two external additional batteries can be mounted N8103 104A SAS Controller Card performance PCI EXPRESS x8 Dedicated to connecting external dev...

Страница 86: ...128 10GBASE Adapter SFP 2ch Card performance PCI EXPRESS 2 0 x8 For additional LAN port Prepare SFP module N8104 129 if needed Teaming AFT SFT ALB and bonding with additional 10GBASE SFP board is supp...

Страница 87: ...onal battery N8103 162 can be mounted Up to one internal and two external additional batteries can be mounted N8103 104A SAS Controller Card performance PCI EXPRESS x8 Dedicated to connecting external...

Страница 88: ...10GBASE Adapter SFP 2ch Card performance PCI EXPRESS 2 0 x8 For additional LAN port Prepare SFP module N8104 129 if needed Teaming AFT SFT ALB and bonding with additional 10GBASE SFP board is support...

Страница 89: ...ries can be mounted MegaRAID CacheCade N8103 156 can be mounted N8103 160 RAID Controller 1 GB RAID 0 1 5 6 Card performance PCI EXPRESS 2 0 x8 Dedicated to connecting external devices Up to two cards...

Страница 90: ...annot be mounted in 2C on WS2003 N8104 133 1000BASE T Adapter 4ch Card performance PCI EXPRESS 2 0 x2 For additional LAN port Teaming AFT SFT ALB and bonding with onboard LAN and N8104 135 138 132 133...

Страница 91: ...Confirm the installation position with the reference to the table on 1 17 2 Supported boards and available slots 4 Remove a screw from the PCI rise card and remove the blank cover Note Keep the remove...

Страница 92: ...sages refer to Chapter 3 1 POST Error Message in Maintenance Guide 10 Start the configuration utility installed on the mounted board to set up the board Availability or startup and operation procedure...

Страница 93: ...S Setup utility select PCI Configuration from the Advanced menu and then make sure that the parameter of PCI Slot xx ROM xx is PCI slot number is set to Enabled When connecting a RAID Controller set t...

Страница 94: ...RAID Controller 8 2 When five or more hard disk drives are installed Connect SAS SATA cable removed in Step 9 to connector Ports 0 3 on RAID Controller Connect SAS SATA cable provided with the server...

Страница 95: ...additional hard disk drives 1 18 1 Installation Follow steps below to install an additional HDD cage 1 Refer to steps 1 to 6 in Chapter 2 1 3 Overview of Installation and Removal for preparations 2 R...

Страница 96: ...d in Step 2 6 Disconnect SAS cable from the factory installed HDD cage 7 Install expander board to Expansion Bay and secure it with four screws provided with 2 5 inch HDD cage 8 Connect the SAS cable...

Страница 97: ...Connect the provided SGPIO cable to factory installed HDD cage and additional HDD cage 12 Install support bar PCI riser card and then install the top cover 13 Attach the ID label to the front face of...

Страница 98: ...rive 1 19 1 Installation Install an optical disk drive in the following procedure 1 Refer to Steps 1 to 6 in Chapter 2 1 3 Overview of Installation and Removal for preparations 2 Lift the lock of opti...

Страница 99: ...de 99 Chapter 2 Preparations 6 Secure the bracket to optical disk drive with a screw 7 Insert the optical disk drive and secure the drive tray 8 Connect the optical disk drive cable 1 19 2 Removal To...

Страница 100: ...If the hard disk drive contains valuable data be sure to backup the hard disk drive before installing the RAID Controller and configuring the RAID System Note In the RAID System use hard disk drives t...

Страница 101: ...necting cables Refer to the figures below for how to connect cables If using optional RAID Controller 1 to 8 hard disk drives Optional RAID Controller Backplane Hard Disk Drive Ports 0 3 MINISAS1 Slot...

Страница 102: ...ne Hard Disk Drive Ports 0 3 MINISAS1 MINISAS3 Standard HDD Cage MINISAS1 Slot 0 Slot 1 Slot 2 Slot 3 MINISAS4 Standard HDD Cage MINISAS2 Slot 4 Slot 5 Slot 6 Slot 7 Ports 4 7 MINISAS2 MINISAS5 Additi...

Страница 103: ...drives in a group pack must have the same capacity interface type and rotational speed If you intend to install the OS to the RAID System the process from RAID configuration to OS installation can be...

Страница 104: ...nstalling Support Bar Install support bar in reverse order of removal Refer to Chapter 2 1 8 Removing Support Bar 1 23 Installing PCI Riser Card Install PCI riser card in reverse order of removal Refe...

Страница 105: ...the RAID System all the hard disk drives in a group pack must have the same capacity interface type and rotational speed Bays can contain up to 8 hard disk drives when HDD cage is added 16 HDDs can b...

Страница 106: ...e frame Hold the drive carrier firmly with both hands 6 Slowly close the handle The drive carrier is locked making a clicking sound Note When you push the drive into the slot confirm the handle got ho...

Страница 107: ...ard disk drive in the RAID System In the RAID System you can use the auto rebuild feature to restore data back to the state before a failure occurred by writing the data saved before the replacement t...

Страница 108: ...alled 800 1000W N8100 551F E5 2670 Installed Up to 16 800 1000W N8100 552F E5 2690 17 or more 1000W 1 26 1 Cold Redundant Feature The server supports the feature to optimize power efficiency as descri...

Страница 109: ...ink green when the power cords are connected If the power unit is not connected with the power cord its AC POWER LED goes on amber When the power cords are connected AC POWER LEDs on both power supply...

Страница 110: ...and press the POWER switch on the server to turn off the power Tips In the redundant power configuration with two power supply units and if either one of power supply units fails the failing power sup...

Страница 111: ...User s Guide 111 Chapter 2 Preparations 1 27 Installing the Front Bezel When installing Front Bezel engage catches of front bezel with those on mounting ear After installing Front Bezel lock it with B...

Страница 112: ...nly in the specified environment Do not connect the ground wire to a gas pipe CAUTION Be sure to observe the following precautions to use the server safely Failure to observe the precautions may cause...

Страница 113: ...air or dust includes components accelerating corrosion ex sulfur sodium chloride or conductive metals Place where chemicals may be accidentally sprayed over Place where a carpet not subject to anti st...

Страница 114: ...cautions to use the server safely Failure to observe the precautions may cause burns injury and property damage For details refer to Safety precautions in Precautions for Use Do not drop Do not leave...

Страница 115: ...ing inner rails Make sure the orientation of inner rails Inner rail L Inner rail R Installing inner rails 1 Mount an inner rail marked as R to the right side of the server and L to the left side when...

Страница 116: ...sure that the rail is installed at the same height as the other slide rail assemblies already installed Important Confirm that the rail assemblies are securely locked so that they will not fall off Ti...

Страница 117: ...rail from left and right outer rails until the it is locked Note Make sure that locking mechanism work normally 2 With two or more persons firmly hold the server and mount it to the rack 3 When the s...

Страница 118: ...er out while pressing the buttons located on both side of the front of the server 4 Because there are stoppers the server will come to a stop halfway Press and hold Rail Stopper on the rails and pull...

Страница 119: ...er to Chapter 2 2 1 2 Installing the server to the rack or removing it from the rack 2 Removal procedure to remove the server from the rack 2 Push the unlock lever on outer rail to the direction shown...

Страница 120: ...death or serious injury For details refer to Safety precautions in Precautions for Use Do not hold the power plug with wet hands Do not connect the ground wire to a gas pipe CAUTION Be sure to observ...

Страница 121: ...Finally connect the provided power cord to an outlet 1 For connecting with UPS refer to the next section Ports for data transmission Management LAN port Device with serial interface 1 Connect the powe...

Страница 122: ...r supply UPS To connect the power cord of the server to the uninterruptible power supply UPS use the connector output on the rear of the UPS For details refer to the manual supplied with the UPS When...

Страница 123: ...tings by following the instructions in this section 3 EXPRESSSCOPE Engine 3 EXPRESSSCOPE Engine 3 provides useful features through the Baseboard Management Controller BMC 4 EXPRESSBUILDER EXPRESSBUILD...

Страница 124: ...ces that connect to the display monitor and the server Note If the power cord is connected to power control system such as an Uninterruptible Power Supply UPS make sure that the power control system i...

Страница 125: ...ears 2 If Enabled is specified for Password On Boot in Security menu of SETUP you will be prompted to enter password after the logo is displayed If you enter the incorrect password three times consecu...

Страница 126: ...troller board is installed a message that prompts you to start the dedicated utility to set each board is displayed Example If an optional RAID Controller is installed Press Ctrl H for Web BIOS The ut...

Страница 127: ...ing SETUP Run POST following Chapter 3 1 1 1 POST sequence After a while the following message will be displayed on the lower left of the screen Press F2 SETUP F3 Internal Flash Memory F4 ROM Utility...

Страница 128: ...the selected item You cannot use this key when a menu which has on the left is selected Enter key Press this key to confirm the selected parameter Esc key Pressing this key takes you to the previous...

Страница 129: ...F3 key If you press this key the following window appears If you select Yes restore the parameters of the currently selected item to the default setting This might be different from the parameters con...

Страница 130: ...ration PCI Device Controller and Option ROM Settings PCIXX Slot Option ROM Enabled XX is PCI slot number of the option board Boot Change the boot order of devices Boot Boot Option Priorities Change th...

Страница 131: ...password 3 times operation stops You cannot operate further Turn off the power Saving changes If you finish configuration select Save Exit and then Save Changes and Exit to save changes and exit If y...

Страница 132: ...irtual Flash is always connected as USB mass storage 3 2 EXPRESSSCOPE ENGINE 3 Network configuration To enable EXPRESSSCOPE Engine 3 to be used via network network configuration is required Below is a...

Страница 133: ...ress Subnet Mask Tips If Shared BMC LAN is enabled Web feature remote media KVM feature or command line interface feature may be interrupted In this case wait for a while and connect with network agai...

Страница 134: ...eature select Tool menu in the menu after boot Storage of documents Stores various documents including User s Guide Installation Guide and Maintenance Guide Documents and some software components are...

Страница 135: ...ftware Components Express5800 R120d 2M User s Guide 135 Chapter 3 Setup 5 Installing Software Components Continue to install software components such as OS Refer to the instructions below Installation...

Страница 136: ...he server is connected to a UPS refer to the documentation supplied with the UPS or the documentation for the application controlling the UPS 1 Shut down the OS 2 The server automatically turns off af...

Страница 137: ...Express5800 R120d 2M User s Guide 137 NEC Express5800 Series Express5800 R120d 2M Appendix 1 Specifications 2 Interrupt Lines 4 4...

Страница 138: ...et Dedicated to RAID Controller 1 x PCI EXPRESS 3 0 x8 lane x8 socket Dedicated to LAN riser card Graphics Chip VideoRAM Management controller chip 32 MB Graphic display resolution 16 770 000 colors 6...

Страница 139: ...Server 2003 R2 Enterprise Edition Microsoft Windows Server 2003 R2 Standard x64 Edition Microsoft Windows Server 2003 R2 Enterprise x64 Edition Microsoft Windows Server 2008 Standard Microsoft Window...

Страница 140: ...devices Interrupt lines As factory settings interrupt lines are assigned as follows IRQ Peripheral Device Controller IRQ Peripheral Device Controller 0 System timer 12 SM Bus 1 13 Numeric data proces...

Отзывы: