Message format of the 

Set parameter

 is as follows,  

 

 

 

Refer to section 5.3 

Set parameter

 for more details. 

 

4

Set Parameter reply 

The monitor replies with this message for a confirmation of the 

Set parameter message

 Message format of the 

Set parameter reply

 is as follows, 

 

Refer to section 5.4 

Set parameter reply

 for more details. 

 

5

Command 

Command message

 format depends on each command. 

Usually, this 

command message

 is used for some non-slider controls and some special operations, 

such as 

Save current settings

Get timing report

power control

Schedule

, etc. Refer to 

section 5.5 

Commands message

 for more details. 

 

6

Command reply 

The monitor replies to a query from the controller.  

Command reply message

 format depends on each command.  

Refer to section 5.5 

Commands message

 for more details.

 

 

4.5 Check code 

 

Check code is the Block Check Code (BCC) between the Header and the End of Message except SOH.

 

 

 

 

 

 

 

 

 

 

 

D

n+1

 = D

1

 XOR D

2

 XOR D

3

 XOR ,,, D

XOR: Exclusive OR 

 

OP code 

page 

OP code 

Set Value 

STX 

Hi 

Lo 

Hi 

Lo 

MSB 

 

 

LSB 

ETX 

Result 

OP code 

page 

OP code 

Type 

Max value 

Requested setting 

Value 

ETX 

STX 

Hi 

Lo 

Hi 

Lo 

Hi 

Lo 

Hi 

Lo 

MSB 

 

 

LSB 

MSB 

 

 

LSB 

 

Header 

Message 

Check code 

Delimiter 

 

 

2

7

 

2

6

 

2

5

 

2

4

 

2

3

 

2

2

 

2

1

 

2

0

 

SOH 

D

0

 

 

 

 

 

 

 

 

 

Reserved 

D

1

 

 

 

 

 

 

 

 

 

Destination 

D

2

 

 

 

 

 

 

 

 

 

Source 

D

3

 

 

 

 

 

 

 

 

 

Type 

D

4

 

 

 

 

 

 

 

 

 

Length(H) 

D

5

 

 

 

 

 

 

 

 

 

Length(L) 

D

6

 

 

 

 

 

 

 

 

 

STX 

D

7

 

 

 

 

 

 

 

 

 

Data 

D

8

 

 

 

 

 

 

 

 

 

  | 

 

 

 

 

 

 

 

 

  | 

 

 

 

 

 

 

 

 

ETX 

D

n

 

 

 

 

 

 

 

 

 

Check code 

D

n+1

 

Содержание MultiSync X461UNV

Страница 1: ...or via LAN control on User s manual 3 Communication Parameter 3 1 RS 232C Remote control 1 Communication system Asynchronous 2 Interface RS 232C 3 Baud rate 9600bps 4 Data length 8bits 5 Parity None 6 Stop bit 1 bit 7 Communication code ASCII 3 2 LAN control 1 Communication system TCP IP Internet protocol suite 2 Interface Ethernet CSMA CD 3 Communication layer Transport layer TCP Using the payloa...

Страница 2: ... Check Code Delimiter Get Parameter Reply Save Current Setting Command Get Parameter Header Message Check Code Delimiter The controller sends command to get a value from the monitor that you want to change The monitor replies a current value of the requested item The controller sends commands to set an adjusted value The monitor replies to the controller for confirmation The controller sends comma...

Страница 3: ... K 36 64h 61 7Dh 86 96h 12 4Ch L 37 65h 62 7Eh 87 97h 13 4Dh M 38 66h 63 7Fh 88 98h 14 4Eh N 39 67h 64 80h 89 99h 15 4Fh O 40 68h 65 81h 90 9Ah 16 50h P 41 69h 66 82h 91 9Bh 17 51h Q 42 6Ah 67 83h 92 9Ch 18 52h R 43 6Bh 68 84h 93 9Dh 19 53h S 44 6Ch 69 85h 94 9Eh 20 54h T 45 6Dh 70 86h 95 9Fh 21 55h U 46 6Eh 71 87h 96 A0h 22 56h V 47 6Fh 72 88h 97 A1h 23 57h W 48 70h 73 89h 98 A2h 24 58h X 49 71h ...

Страница 4: ... to the section 6 Message format for more detail 1 Get current parameter The controller sends this message when you want to get the status of the monitor For the status that you want to get specify the OP code page and OP code refer to Appendix A Operation code table Message format of the Get current parameter is as follows Refer to section 5 1 Get current parameter from a monitor for more details...

Страница 5: ...e etc Refer to section 5 5 Commands message for more details 6 Command reply The monitor replies to a query from the controller Command reply message format depends on each command Refer to section 5 5 Commands message for more details 4 5 Check code Check code is the Block Check Code BCC between the Header and the End of Message except SOH Dn 1 D1 XOR D2 XOR D3 XOR Dn XOR Exclusive OR OP code pag...

Страница 6: ...0h xor 30h xor 30h xor 36h xor 34h xor 03h 77h 4 6 Delimiter Packet delimiter code ASCII CR 0Dh Header Message SOH Reserved Destination Address Source Address Message type Message length STX OP code page OP code Set Value ETX Check code BCC Delimiter 01 30 41 30 45 30 41 02 30 30 31 30 30 30 36 34 03 77 0D D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 D14 D15 D16 D17 D18 Header Message Check code ...

Страница 7: ... OP code page Lo ASCII 2 32h Refer to Operation code table Appendix A 4th 5th bytes OP code Operation code Refer to Appendix A Operation code table for each item OP code data must be encoded to ASCII characters Ex The byte data 3Ah must be encoded to ASCII characters 3 and A 33h and 41h OP code 3Ah OP code Hi ASCII 3 33h OP code Lo ASCII A 41h Refer to Operation code table 6th byte ETX End of Mess...

Страница 8: ...Ah is encoded to ASCII character 1 and A 31h and 41h 8th 9th bytes Type Operation type code 00h Set parameter 01h Momentary Like the Auto Setup function which automatically changes the parameter This returned value from the monitor is encoded to ASCII characters Ex The byte data 01h is encoded to ASCII character 0 and 1 30h and 31h 10th 13th bytes Max value Maximum value which monitor can accept 1...

Страница 9: ...byte STX Start of Message ASCII STX 02h 2nd 3rd bytes Result code ASCII 0 0 30h 30h No Error ASCII 0 1 30h 31h Unsupported operation with this monitor or unsupported operation under current condition 4th 5th bytes OP code page Echoes back the Operation code page for confirmation Reply data from the monitor is encoded to ASCII characters Ex OP code page 02h OP code page ASCII 0 and 2 30h and 32h Re...

Страница 10: ... the monitor to store the adjusted value Send OC 30h 43h as Save current settings command Complete Save Current setting command packet as follows ASCII 01h 30h 41h 30h 41h 30h 34h 02h 30h 43h 03h CHK 0Dh SOH 0 A 0 A 0 4 STX 0 C ETX CHK CR The monitor replies the packet for confirmation as follows SOH 0 0 A B 0 6 STX 0 0 0 C ETX CHK CR 5 5 2 Get Timing Report and Timing reply The controller request...

Страница 11: ...0 0 A A 0 4 STX B E ETX CHK CR 6 Typical procedure example The following is a sample of procedures to control the monitor these are examples of Get parameter Set parameter and Save current settings 6 1 How to change the Brightness setting Step 1 The controller requests the Monitor to reply with the current brightness setting and capability to support this operation Get parameter Header Message Che...

Страница 12: ...ection 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet Step 3 The controller request the monitor to change the Brightness setting Header SOH 01h Start Of Header 0 30h Reserved Monitor ID Specify the Monitor ID of which you want to change a setting Ex If Monitor ID is 1 specify A 0 30h Message sender is the controller E 45h Message Type is Set parameter command 0 A 30h 41h Messa...

Страница 13: ...der Message Check code Delimiter SOH 0 Monitor ID 0 A 0 4 STX 0 C ETX BCC CR Header SOH 01h Start Of Header 0 30h Reserved Monitor ID Specify the Monitor ID which you want to store the setting Ex If Monitor ID is 1 specify A 0 30h Message sender is the controller A 41h Message type is Command 0 4 30h 34h Message length is 4 bytes Message STX 02h Start of Message 0 C 30h 43h Command code is 0Ch as ...

Страница 14: ...ver is the controller Monitor ID Indicates a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 F 46h Message Type is Set parameter reply 1 2 31h 32h Message length is 18 bytes Message STX 02h Start of Message 0 0 30h 30h Result code No error 0 2 30h 32h Operation code page number is 2 7 8 37h 38h Operation code is 78h in the page 2 0 0 30h 30h This operation is Set par...

Страница 15: ...g Monitor ID is 1 D 44h Message Type is Get parameter reply 1 2 31h 32h Message length is 18 bytes Message STX 02h Start of Message 0 0 30h 30h Result code No error 0 2 30h 32h Operation code page number is 2 7 9 37h 39h Operation code is 79h in the page 2 0 0 30h 30h This operation is Set parameter type F F F F 46h 46h 46h 46h Maximum value 0 0 3 2 30h 30h 33h 32h The temperature is 25 degrees Ce...

Страница 16: ...h the current power status Header SOH 01h Start Of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message Type is Command reply 1 2 31h 32h Message length is 18 bytes Message STX 02h Start of Message 0 2 30h 32h Reserved data 0 0 30h 30h Result code 00 No Error 01 Unsupported ...

Страница 17: ...Header SOH 01h Start Of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command reply N N Message length Note The maximum data length that can be written to the monitor at a time is 32bytes Ex The byte data 20h is encoded as ASCII characters 2 and 0 32h and 30h ...

Страница 18: ...out data length is 32bytes Secondly set 20h Read data from the 32bytes offset point in the Asset data area Maximum readout length is 32bytes at a time ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Asset data to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID...

Страница 19: ...rs strings ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies a data for confirmation Header Message Check code Delimiter SOH 0 0 Monitor ID B N N STX 0 0 C 0 0 E 0 0 Data 0 Data 1 Data N ETX BCC CR Header SOH 01h Start Of Header 0 30h Reserved 0 30h Message receiver is the controller...

Страница 20: ...est command ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Date Time to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 1 4 STX C 3 1 1 YY MM DD WW HH MN DS ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Mo...

Страница 21: ...This command is used in order to write the setting of the Date Time 1 The controller requests the monitor to write Date Time Header Message Check code Delimiter SOH 0 Monitor ID 0 A 1 2 STX C 2 1 2 YY MM DD WW HH MN DS ETX BCC CR Header SOH 01h Start Of Header 0 30h Reserved Monitor ID Specify the Monitor ID of which you want to change the setting Ex If Monitor ID is 1 specify A 0 30h Message send...

Страница 22: ...he monitor replies a data for confirmation Header Message Check code Delimiter SOH 0 0 Monitor ID B 1 6 STX C 3 1 2 ST YY MM DD WW HH MN DS ETX BCC CR Header SOH 01h Start Of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command reply 1 6 31h 36h Message lengt...

Страница 23: ...ule Read This command is used in order to read the setting of the Schedule 1 The controller requests the monitor to read Schedule Header Message Check code Delimiter SOH 0 Monitor ID 0 A 0 8 STX C 2 1 3 PG ETX BCC CR Header SOH 01h Start Of Header 0 30h Reserved Monitor ID Specify the Monitor ID of which you want to get status Ex If Monitor ID is 1 specify A 0 30h Message sender is the controller ...

Страница 24: ...G Program No 0 0 30h 30h Program No 1 0 6 30h 36h Program No 7 ON_HOUR Turn on time hour 0 0 30h 30h 00 1 7 31h 37h 23 17h 1 8 31h 38h ON timer isn t set ON_MIN Turn on time minute 0 0 30h 30h 0 3 B 33h 42h 59 3 C 33h 43h On timer isn t set OFF_HOUR Turn off time hour 0 0 30h 30h 00 1 7 31h 37h 23 17h 1 8 31h 38h Off timer isn t set OFF_MIN Turn off time minute 0 0 30h 30h 0 3 B 33h 42h 59 3Bh 3 C...

Страница 25: ...for a BCC calculation Delimiter CR 0Dh End of packet 10 2 Schedule Write This command is used in order to write the setting of the Schedule 1 The controller requests the monitor to write Schedule Header Message Check code Delimiter SOH 0 Monitor ID 0 A 1 8 STX C 2 1 4 PG ON HOUR ON MIN OFF HOUR OFF MIN INPUT WD FL P MODE ETX BCC CR Header SOH 01h Start Of Header 0 30h Reserved Monitor ID Specify t...

Страница 26: ...IDEO2 0 A 30h 41h S VIDEO 0 B 30h 42h OPTION DTV 0 C 30h 43h OPTION COMPONENT 0 D 30h 44h OPTION DIGITAL 0 E 30h 45h OPTION ANALOG Please select active input on your system setting If you select inactive input here the input change execution will be ignored WD Week setting bit 0 Monday bit 1 Tuesday bit 2 Wednesday bit 3 Thursday bit 4 Friday bit 5 Saturday bit 6 Sunday EX 0 1 30h 31h Monday 0 4 3...

Страница 27: ...h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command reply 1 A 31h 41h Message length Message STX 02h Start of Message C 3 1 4 43h 33h 31h 34h Schedule writes reply command ST Schedule Status command 0 0 30h 30h No error 0 1 30h 31h Error PG ON HOURS ON MIN OFF HOURS OFF MIN INPUT WD ...

Страница 28: ...bit 1 0 once 1 Every week bit 2 0 Disable 1 Enable When bit 0 and bit 1 are 1 it behaves as Everyday EX 0 1 30h 31h Disable Everyday 0 4 30h 34h Enable once P MODE Picture mode 0 0 30h 30h HI_BRIGHT 0 1 30h 31h STANDARD 0 2 30h 32h sRGB 0 3 30h 33h CINEMA 0 4 30h 34h ISF_DAY 0 5 30h 35h ISF_NIGHT 0 6 30h 36h AMBIENT_1 0 7 30h 37h AMBIENT_2 If picture mode setting is skipped the reply also won t ha...

Страница 29: ...nfirmation Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 C STX C 3 1 5 ST PG EN ETX BCC CR Header SOH 01h Start Of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command reply 0 C 30h 43h Message length Message STX 02h Start of Message C 3 1 5 43h ...

Страница 30: ...ssage receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command reply N N Message length Note The maximum data length that can be written to the monitor at a time is 32bytes Ex The byte data 20h is encoded as ASCII characters 2 and 0 34h and 30h Message STX 02h Start of Message A 1 41h 31h Applicati...

Страница 31: ...eck Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies the serial No data to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B N N STX C 3 1 6 Data 0 Data 1 Data n ETX BCC CR Header SOH 01h Start Of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When t...

Страница 32: ...imiter SOH 0 0 Monitor ID B N N STX C 3 1 7 Data 0 Data 1 Data n ETX BCC CR Header SOH 01h Start Of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command reply N N Message length Note The maximum data length that can be returned from the monitor at a time is 3...

Страница 33: ...nder is the controller A 41h Message type is Command 1 0 31h 30h Message length Message STX 02h Start of Message C 2 1 D 43h 32h 31h 44h Security Lock Control command EN P1 P2 P3 P4 Lock condition control data EN Enable Disable 0 0 30h 30h Disable 0 1 30h 31h Enable P1 Security Pass code 1st 0 0 30h 30h 0 0 9 30h 39h 9 P2 Security Pass code 2nd 0 0 30h 30h 0 0 9 30h 39h 9 P3 Security Pass code 3rd...

Страница 34: ...e C 3 1 D 43h 33h 31h 44h Security Lock Control reply command ST EN Lock condition result data ST Status 0 0 30h 30h No error 0 1 30h 31h Error EN Enable Disable Current condition 0 0 30h 30h Disable 0 1 30h 31h Enable ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Страница 35: ...0h Red 9Bh Yellow 9Ch Green 9Dh Cyan 9Eh Blue 9Fh Magenta A0h 0 50 32h center 100 64h Saturation 8Ah 0 pale 10 0Ah deep Gamma Selection 02h 68h Gamma Table Selection 1 Native Gamma 4 Gamma 2 2 8 Gamma 2 4 7 S Gamma 5 DICOM SIM 6 Programmable Adaptive Contrast 02h 8Dh 0 None 1 Off 2 Low 3 Middle 4 High Noise Reduction 02h 20h 0 Off 16 10h High Movie Settings Film Mode 02h 23h 1 Off 2 Auto PICTURE P...

Страница 36: ... 0 Left side Max Right side Depends on a display timing V Position 00h 30h 0 Bottom side Max Top side Depends on a display timing Clock 00h 0Eh 0 Max Clock Phase 00h 3Eh 0 Max H Resolution 02h 50h 0 Low Max High V Resolution 02h 51h 0 Low Max High Input Resolution 02h DAh 1 Auto 2 1024x768 3 1280x768 4 1360x768 5 1366x768 6 1400x1050 7 1680x1050 Base Zoom 02h CEh 3 16 9 ZOOM 4 14 9 ZOOM 5 Dynamic ...

Страница 37: ... Line out N A SURROUND 02h 34h 1 Off 2 Low 3 High Not available on X461UN Audio Input 02h 2Eh 1 Audio 1 PC 2 Audio 2 3 Audio 3 4 HDMI 5 TV Option AUDIO Menu tree reset Audio 02h CBh 0 None 4 Reset Audio category Momentary Off Timer 02h 2Bh 0 Off 1 1 hour 24 24 hours 1 hour step Enable Schedule 02h E5h 0 No Mean 1 No 1 Enable 7 No 7 Enable Disenable Schedule 02h E6h 0 No Mean 1 No 1 Disable 7 No 7 ...

Страница 38: ...e 1 On 2 Off PIP Input Sub input 02h 73h 0 No mean 1 VGA 2 RGB HV 3 DVI 4 HDMI Set only 5 Video1 6 Video2 7 S Video 10 TV 12 DVD HD1 13 Option 14 DVD HD2 15 Display Port 17 HDMI This operation has limitation of selection Please refer to the monitor instruction manual Menu tree reset PIP 02h CBh 0 None 6 Reset PIP category Momentary Language 00h 68h 1 English 2 German 3 French 4 Spanish 5 Japanese ...

Страница 39: ...f 2 Enable On Tile Matrix Mode 02h D3h 1 Disable Off and display frame 2 Enable On 3 Disable Off and erase frame Set only Power On Delay 02h D8h 0 Off 0sec 50 50sec Power Indicator 02h BEh 0 None 1 Off 2 On External control 10h 3Eh 0 No mean 1 RS 232C 2 LAN Setting copy N A MULTI DISPLAY Menu tree reset Multi Display 02h CBh 0 None 8 Reset Multi Display category Momentary Power Save 00h E1h 0 Off ...

Страница 40: ...2Fh Priority3 10h 30h Priority4 10h 31h Custom Detect Priority5 10h 32h 0 No mean 1 VGA 2 RGB HV 3 DVI 4 HDMI Set only 5 Video1 6 Video2 7 S Video 10 TV 12 DVD HD1 13 Option 14 DVD HD2 15 Display Port 17 HDMI Input change N A Equalize 10h 3Dh 0 No mean 1 Off 2 On Pole 10h 36h 0 255 FFh Peak 10h 37h 0 255 FFh Gain 10h 38h 0 255 FFh Offset 10h 39h 0 255 FFh Long Cable Manual SYNC Terminate 02h E1h 1...

Страница 41: ...VD HD2 15 Display Port 17 HDMI Audio Input 02h 2Eh 1 Audio 1 PC 2 Audio 2 3 Audio 3 4 HDMI 5 TV Option Volume UP Down 00h 62h 0 whisper 100 loud Mute 00h 8Dh 0 2 UNMUTE 1 MUTE MTS 02h 2Ch 0 None 1 Main 2 Sub 3 Main Sub This operation requires option TV tuner Sound 02h 34h 1 Off 2 Low 3 High Not available on X461UN Picture Mode 02h 1Ah 1 sRGB 3 Hi Bright 4 Standard 5 Cinema sRGB PC mode only Cinema...

Страница 42: ...ture 02h 76h 0 Off 1 Capture Momentary Signal Information 02h EAh 0 No Action 1 Off No indication 2 On Indication TV Channel UP DOWN 00h 8Bh 0 No Action 1 Up 2 Down This operation requires option TV tuner Select Temperature sensor 02h 78h 1 Sensor 1 2 Sensor 2 3 Sensor 3 Temperature sensor Readout a temperature 02h 79h Returned value is 2 s complement Refer to section 6 2 Read only Readout carbon ...

Страница 43: ...cument provides the technical information for users NEC Display Solutions Ltd reserves the right to change or modify the information contained herein without notice NEC Display Solutions Ltd makes no warranty for the use of its products and bears no responsibility for any errors or omissions which may appear in this document ...

Отзывы: