background image

English-34

Alert error message list

Error number

* ErrorCode

Alert mail Message

Explanation

Measure

70h ~ 7Fh 

The monitor’s power supply is not 
functioning normally.

Standby power Abnormal

Please contact your supplier.

80h ~ Fh 

The cooling fan has stopped.

Cooling fan Abnormal

Please contact your supplier.

90h ~ 9Fh 

The monitor’s back light unit is not 
functioning normally. 

Backlight abnormal

Please contact your supplier.

A0h ~ AFh

The monitor is overheated.

Temperature Abnormal

Please contact your supplier.

A2h

SENSOR reached at the temperature 
that the user had specifi ed.

*condition: DISPLAY PROTECTION-FAN 
CONTROL-COOLING FAN = AUTO

Reconfi rm the setting condition from 
OSD (DISPLAY PROTECTION-FAN 
CONTROL) or please contact your 
supplier.

B0h ~ BFh 

The monitor doesn’t have the input 
signal.

No signal

Please check “No picture” in 
“Troubleshooting”.

C0h ~ CFh 

The monitor caused the problem of the 
abnormal of option board. 

Option board abnormal

Please contact your supplier.

Sample: The following examples are content of Alert Mail that informs the temperature anomaly of monitor.

Sample: The following examples are content of test mail by browser.

Содержание MultiSync P402

Страница 1: ...User s Manual MultiSync P402 MultiSync P462 MultiSync P552...

Страница 2: ...English 16 Power Indicator English 17 Using Power Management English 17 Selecting a video source English 17 Picture Aspect English 17 Information OSD English 18 Picture Mode English 18 OSD On Screen...

Страница 3: ...ot installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installa...

Страница 4: ...equipment please contact your supplier For all other cases please use a power cord that matches the AC voltage of the power outlet and has been approved by and complies with the safety standard of you...

Страница 5: ...ot connect to a peripheral device with wiring that might have excessive voltage Connecting to a TV Cable distribution system should be grounded earthed in accordance with ANSI NFPA 70 the National Ele...

Страница 6: ...x 2 Setup Manual Cable cover P402 P462 Video Signal Cable Mini D SUB 15 pin to Mini D SUB 15 pin Wireless Remote Control and AA Batteries Cable cover P552 Remember to save your original box and packi...

Страница 7: ...mation Make sure there is no gap between the monitor and the bracket Installation Mounting Bracket Screw Washer Unit 11 12 mm Thickness of bracket and washer Screw length should equal depth of hole 11...

Страница 8: ...alling the LCD monitor stand handle the unit with care to avoid pinching your fingers Optional table top stand Table Protective Sheet NOTE Install the stand so the long end of the feet face forward Us...

Страница 9: ...the OSD menu is turned off Acts as EXIT button within the OSD to move to previous menu Remote control sensor and Power Indicator Receives the signal from the remote control when using the wireless rem...

Страница 10: ...ector To output the DVI signal from either DVI IN or HDMI connection To output the DVI signal from the HDMI connection the HDMI input must be selected HDMI connector To input digital HDMI signals VGA...

Страница 11: ...l External speaker switch Kensington Lock For security and theft prevention Option board slot Slot 1 and slot 2 type accessories are available Please contact your supplier for detailed information NOT...

Страница 12: ...hen surround is set to ON KEYPAD Press buttons to set and change passwords change channel and set REMOTE ID ENT button 2 DISPLAY button Turns on off the information OSD See page 18 MENU button Turns o...

Страница 13: ...Yes Yes No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes DVD HD DVD HD Yes Yes Yes Yes Yes Yes No No Yes Yes No No No No Yes Yes No No Yes Yes SCART SCART Yes Yes Yes Yes Yes Yes No No Yes Yes No No No...

Страница 14: ...control batteries The remote control is powered by two 1 5V AA batteries To install or replace batteries A Press and slide to open the cover B Align the batteries according to the and indications ins...

Страница 15: ...st the sound Make volume adjustments when required 9 Adjust the screen See pages 20 and 21 Make adjustments of the screen display position when necessary 10 Adjust the image See page 20 Make adjustmen...

Страница 16: ...deo signal Dotted lines audio signal Connected equipment Connecting terminal Setting in Terminal Mode Input signal name Connecting Audio terminal Input button in remote control AV DVI DVI D DVI MODE D...

Страница 17: ...t requirements and any special identification or configuration your monitor s image and monitor may require Input TMDS signals conforming to DVI standards To maintain display quality use a cable that...

Страница 18: ...rn green while powered on and will turn red or amber while powered off NOTE The Main Power Switch must be in the ON position in order to power up the monitor using the remote control or the Power Butt...

Страница 19: ...en and Amber blink alternately Diagnosis Detecting failure Red Blinking See Troubleshooting page 36 1 If OFF is selected in POWER INDICATOR page 23 the LED will not light when the LCD monitor is in ac...

Страница 20: ...s NOTE When picture mode is set to AMBIENT1 or AMBIENT2 BACKLIGHT AUTO BRIGHTNESS and BACKLIGHT in SCREEN SAVER function are disabled Do not cover Ambient light sensor when you use AMBIENT1 or AMBIENT...

Страница 21: ...VIRONMENT CARBON FOOTPRINT 86 0 Input source Main Menu Icons Main Menu Item Sub Menu Key Guide Adjustment Settings Remote Control Press UP or DOWN button to select sub menu Press SET Press UP or DOWN...

Страница 22: ...NATIVE except sRGB setting NATIVE Gamma correction is handled by the LCD panel 2 2 Typical display gamma for use with a PC 2 4 Good for video DVD etc S GAMMA Special gamma for certain types of movies...

Страница 23: ...ST H POSITION V POSITION CLOCK PHASE H RESOLUTION V RESOLUTION ASPECT AUDIO VOLUME Increases or decreases output volume level 40 BALANCE Adjust the balance of L R volume Press button to move the stere...

Страница 24: ...where the PIP appears on the screen X 95 Y 92 ASPECT Selects sub picture aspect FULL NORMAL and WIDE See page 17 FULL TEXT TICKER OFF MODE Enables Text Ticker and allows you to set Horizontal or Verti...

Страница 25: ...monitor will be controlled normally using the remote controller PRIMARY Choose PRIMARY for the first monitor within an RS 232C daisy chain SECONDARY Choose SECONDARY for all subsequent monitors withi...

Страница 26: ...e signal is lost Note When connecting DVI the video card might not stop sending the digital data even though the image might have disappeared If this occurs the monitor will not switch into power mana...

Страница 27: ...RT VIDEO1 VIDEO2 or S VIDEO input CUSTOM DETECT Set the priority of input signals When CUSTOM DETECT is selected monitor searches listed inputs only INPUT CHANGE Sets input change speed NOTE When QUIC...

Страница 28: ...is available for slot 2 type PC OFF WARNING If OPTION POWER is OFF a warning message appears when monitor power is turned off NOTE Warning message does not appear when monitor power is turned off by...

Страница 29: ...e remains visible on the screen Unlike CRT monitors LCD monitors image persistence is not permanent but constant images being displayed for a long period of time should be avoided To alleviate image p...

Страница 30: ...le using the keypad to input the REMOTE CONTROL ID number 1 100 The REMOTE ID NUMBER should match the MONITOR ID number of the display to be controlled Choose 0 to simultaneously control all displays...

Страница 31: ...onitor while aiming at the PRIMARY monitor The MENU OSD will appear on the selected target monitor NOTE If the ID No mode select OSD is showing press the DISPLAY button on the remote control while poi...

Страница 32: ...nction the RS 232C OUT terminal can only be connected to another monitor of the same model Do not connect to other types of equipment To control monitor or multiple monitors that are daisy chained tog...

Страница 33: ...aScript and Cookies and the browser should be set to accept these functions The setting method will vary depending on the version of browser Please refer to the help files and the other information pr...

Страница 34: ...the entry column of the URL Example 2 When the IP address of the monitor is 192 168 73 1 access is gained to the mail alert settings by specifying http 192 168 73 1 index html for the address or the...

Страница 35: ...e mail transmission POP3 Server This specifies the address of the POP3 server that is used in the authentication of the e mail User Name This sets the user name for logging into the authentication ser...

Страница 36: ...bnormal Please contact your supplier A2h SENSOR reached at the temperature that the user had specified condition DISPLAY PROTECTION FAN CONTROL COOLING FAN AUTO Reconfirm the setting condition from OS...

Страница 37: ...y costs reducing emissions and lowering the air conditioning costs of the workplace FullScan Capability Allows you to use the entire screen area in most resolutions significantly expanding image size...

Страница 38: ...ower Switch it should be in the ON position Make certain the computer is not in a power saving mode touch the keyboard or mouse Check to see that the power indicator option in the OSD is set to ON RED...

Страница 39: ...M 4 43NTSC PAL60 S VIDEO Mini DIN 4 pin S VIDEO Y 1 0 Vp p 75 ohm C 0 286 Vp p 75 ohm NTSC 0 3 Vp p 75 ohm PAL SECAM NTSC PAL SECAM 4 43NTSC PAL60 Output Signal DVI DVI D 24pin Digital RGB DVI HDCP Di...

Страница 40: ...43NTSC PAL60 S VIDEO Mini DIN 4 pin S VIDEO Y 1 0 Vp p 75 ohm C 0 286 Vp p 75 ohm NTSC 0 3 Vp p 75 ohm PAL SECAM NTSC PAL SECAM 4 43NTSC PAL60 Output Signal DVI DVI D 24pin Digital RGB DVI HDCP Displa...

Страница 41: ...CAM 4 43NTSC PAL60 S VIDEO Mini DIN 4 pin S VIDEO Y 1 0 Vp p 75 ohm C 0 286 Vp p 75 ohm NTSC 0 3 Vp p 75 ohm PAL SECAM NTSC PAL SECAM 4 43NTSC PAL60 Output Signal DVI DVI D 24pin Digital RGB DVI HDCP...

Страница 42: ...9 D SUB 9P Pin No Name 1 connected to 7 8 2 RXD 3 TXD 4 connected to 6 5 GND 6 connected to 4 7 connected to 1 8 8 connected to 1 7 9 NC This LCD monitor uses RXD TXD and GND lines for RS 232C control...

Страница 43: ...lay com in USA Energy Saving This monitor features an advanced energy saving capability When a VESA Display Power Management Signalling DPMS Standard signal is sent to the monitor the Energy Saving mo...

Отзывы: