5-19
1.7.4. Leakage current test
A leakage current shall be measured under the conditions specified below, in order to confirm that the
requirements of the judgment standard are met.
1) Measuring conditions
•
Measuring instrument : Leakage current meter (A 1500
Ω
resistor shall be incorporated, together
with a bypass capacitor of 0.15
µ
F.)
•
Testing point : Between the exposed metallic block (D-SUB connector) and Phases A and
B of the power source.
•
Condition of the set : A power cable shall be connected without connecting a signal generator. The
see-saw switch on the set side shall be turned ON and OFF.
2) Judgment standard
The leakage current measured shall be 1.5mA or less with an input of 240V AC
×
1.06 +5/-0V (60Hz).
1.7.5. Insulation resistance test
An insulation resistance shall be measured under the conditions specified below, in order to confirm that
the requirements of the judgment standard are met.
(1) Measuring conditions
•
Measuring instrument
: 500V DC megger
•
Testing point
: Between the power circuit block and the exposed metallic block
(D-SUBI connector)
•
Measured value readout
: A test voltage shall be applied for one minute and the resistance value
shall be read out thereafter.
(2) Judgment standard : 10M
Ω
or more