Configuring Your System 3-25
RAID Configurations
Number of
Hard Drives
RAID Level
Configured
Hard Drives
in Array
Description
1
JBOD
1
JBOD (RAID 0) JBOD is an acronym for Just
a Bunch Of Disks. Each drive can operate
independently as with a common host bus
adapter; or multiple drives may be spanned
and seen as a single very large drive. No
redundancy is provided.
2
1
2
Mirroring (RAID 1) Drives are paired and
mirrored. All data is 100% duplicated on an
equivalent drive (fully redundant).
3
5
3
Striping with Parity (RAID 5) Data is striped
across several physical drives. Parity
protection is used for data redundancy.
4
5
3 plus 1 hot
spare drive
Striping with Parity (RAID 5) Data is striped
across three physical drives. Parity protection
is used for data redundancy. This drive is used
as the “Hot Spare.”