Selecting a Site
The system operates reliably in a typical office environment.
You may also choose to install the system into a standard EIA 19-inch rack cabinet
(See “Rack Installation Kit Assembly” on page 2-5).
In both cases, choose a site that is:
■
Near grounded, three-pronged power outlets.
Note:
For the United States and Canada, this means a
NEMA 6-15R outlet for 200-240 VAC. The system cannot be
used on a NEMA 5-15R outlet for 100-120 VAC. For other
international sites, this means three-pronged power outlets
applicable for the electrical code of the region.
Warning
Be sure the power service connection is through a properly
grounded outlet.
■
Clean, dust-free, and well ventilated. Every side ventilating openings kept free of
obstructions. Away from sources of heat, vibration or physical shock.
■
Isolated from strong electromagnetic fields and electrical noise produced by
electrical devices (such as air conditioners, large fans, large electric motors, radio
and TV transmitters, and high-frequency security devices)
■
Spacious enough around the system to allow proper cooling, airflow, and cable
clearance.
Caution
Leave enough space behind the system. Not doing so may
result in overheating and damaging the system.
■
Easily accessible for system maintenance and installation of system upgrades.
Содержание I-Select TS100
Страница 1: ...User s Guide I Select TS100 I Select TW100 ...
Страница 2: ......
Страница 4: ......
Страница 34: ......
Страница 50: ......
Страница 51: ...3 Configuring Your System Configuring Your System BIOS Setup Utility Configuring MotherBoard Jumpers ...
Страница 64: ......
Страница 114: ......
Страница 118: ......
Страница 126: ......
Страница 139: ......
Страница 140: ......