1. IML Error Message
Express5800/R120h-1M, R120h-2M Maintenance Guide
186
Chapter 3 Appendix
Class
Error code
Error message
Action
UEFI
342
NVDIMM Error - Uncorrectable Memory
Error - Processor %1, DIMM %2
(SN:%3-%4-%5-%6). This NVDIMM
will not be available to the operating
system and data may have been lost.
Contact your sales representative.
UEFI
343
IMPORTANT: NVDIMM backup power
has been lost and a future backup is not
possible. Data from the last successful
backup is intact, but data modified after
the last successful backup will be lost if
power cannot be restored.
Check the backup power supply of the NVDIMM.
Back up the contents recorded in the NVDIMM to
other media to protect the data. If the problem
persists, contact your sales representative.
UEFI
344
NVDIMM Error - NVDIMM Controller
Error - Processor %1, DIMM %2
(SN:%3-%4-%5-%6). An error was
found with the NVDIMM controller. The
OS will not use the NVDIMM. Data from
last successful backup is still available,
but will be lost if controller error
persists.
Please take actions in the following order.
1. Back up the contents recorded in the NVDIMM to
other media to protect the data.
2. Contact your sales representative.
UEFI
345
NVDIMM Error - Erase Error -
Processor %1, DIMM %2
(SN:%3-%4-%5-%6). NVDIMM could
not be erased by the NVDIMM
controller FW and future backups are
not possible.
Please take actions in the following order.
1. Back up the contents recorded in the NVDIMM to
other media to protect the data.
2. Contact your sales representative.
UEFI
346
NVDIMM Error - Arming Error -
Processor %1, DIMM %2
(SN:%3-%4-%5-%6). NVDIMM could
not be armed and future backups are
not possible.
Please take actions in the following order.
1. Back up the contents recorded in the NVDIMM to
other media to protect the data.
2. Contact your sales representative.
UEFI
351
IMPORTANT: %1 is not charged
sufficiently to support the
energy-backed persistent memory
installed in the system. The system will
wait for the battery to charge
sufficiently before continuing boot.
Perform one of the following actions.
1. Wait until the battery is fully charged so that the
unit can continue to be operated.
2. Press the <ESC> key to continue operating
without waiting for the battery fully charged.
UEFI
352
IMPORTANT: %1 is not charged
sufficiently to support the
energy-backed persistent memory
installed in the system. System
configured to not wait for battery to
charge. Persistent memory regions
may not be available in the OS.
Perform one of the following actions.
1. Wait until the battery is fully charged so that the
unit can continue to be operated.
2. Change to the setting where the unit operation is
suspended until the battery is fully charged.
UEFI
353
IMPORTANT: Possible Password
Corruption. The PW authentication
algorithm detected an issue which has
been corrected.
Reset your password. To clear the currently set
password, follow the procedure in
Chapter 1 (7.
Resetting and Clearing the Server)
in this manual.
If the problem persists, contact your sales
representative.