2. System BIOS Setup
Express5800/GT110e User’s Guide
112
Chapter 3 Setup
2.4
Cases that Require Configuration
Only if a case applies to any of following cases, use the SETUP utility to change a parameter which was
configured as factory setting. Other than cases described below, do not change the settings. A list of SETUP
parameters and factory settings are described in
Chapter 2 (1. Details of System BIOS)
in "
Maintenance
Guide
".
Category
Description
To be changed
Remark
Basic
Change date and time
Main
→
System Date
Main
→
System Time
Configurable on OS
On/Off NumLock on power ON
Boot
→
Bootup Numlock State
On/Off the function to display
the NEC logo during POST
Boot
→
Quite Boot
→
Disabled
By pressing the <Esc> key,
prevent the display of the logo.
Optional
board
Install RAID Controller board
Advanced
→
PCI Configuration
→
PCI
Slot n Option ROM
→
Enabled
n
is PCI slot number of the
RAID Controller
Boot
Change the boot order of
devices
Boot
→
Boot Option Priorities
→
Change the boot priority
Use remote power on function
(from modem)
Advanced
→
Advanced Chipset
Configuration
→
Wake On Ring
→
Enabled
Use remote power on function
(from RTC alarm)
Advanced
→
Advanced Chipset
Configuration
→
Wake On RTC Alarm
→
Enabled
Control from HW console
terminal
Advanced
→
Serial Port Configuration
→
Change respective setting.
Security
Set a password
Security
→
Administrator Password
→
Enter a password
(Set a password for Administrator first
and then User)
There are two types of
password; Administrator and
User.
Settings for User password is
limited compared to for
Administrator.
UPS
Power link
When the server is supplied
with power from UPS, always
turn on the power.
Server
→
AC-LINK
→
Power On
If it is turned off by using
POWER switch, leave it OFF
even when UPS supplies
power.
Server
→
AC-LINK
→
Last State
Keep the power OFF even
when UPS supplies power.
Server
→
AC-LINK
→
Stay off