8-8 Troubleshooting
On-screen error message
Action
Some configured disks have been removed from your system,
or are no longer accessible. Please check your cables and also
ensure all disks are present.
Press any key to continue, or 'C' to load the configuration utility.
Check if hard disk drives are
connected properly. If the same
error persists, contact your
service representative.
The battery hardware is missing or malfunctioning, or the
battery is unplugged.
If you continue to boot the system, the battery-backed cache
will not function. Please contact technical support for
assistance. Press 'D' to disable this warning (if your controller
does not have a battery).
Press D to hide this message.
The cache contains dirty data, but some VDs are missing or will
go offline, so the cached data can not be written to disk. If this is
an unexpected error, then please power off your system and
check your cables to ensure all disks are present. If you
continue, the data in cache will be permanently discarded.
Press 'X' to acknowledge and permanently destroy the cached
data.
Check if hard disk drives are
connected properly. If the same
error persists, contact your
service representative.NOTE: If
you press X, the data in cache
memory will be lost.
The following VDs are missing: xx
If you proceed (or load the configuration utility), these VDs will
be removed from your configuration. If you wish to use them at
a later time, they will have to be imported. If you believe these
VDs should be present, please power off your system and
check your cables to ensure all disks are present.
Press any key to continue, or 'C' to load the configuration utility.
Check if hard disk drives are
connected properly.
If the same error persists,
contact your service
representative.
The following VDs have missing disks: xx
If you proceed (or load the configuration utility), these VDs will
be marked OFFLINE and will be inaccessible.
Please check your cables and ensure all disks are present.
Press any key to continue, or 'C' to load the configuration utility.
Check if hard disk drives are
connected properly.
If the same error persists,
contact your service
representative.
Your VDs that are configured for write-back are temporarily
running in write-through mode. This is caused by the battery
being charged, missing, or bad.
Please allow battery to charge for 24 hours before evaluating
battery for replacement.
The following VDs are affected: XX
Press any key to continue.
It is no problem if the message is
logged without battery.
There is no additional battery for
the controller, so ignore this
message.
IMPORTANT:
The message "Expansion Rom not initialized" may be
displayed due to insufficient expansion ROM area. Select one of the
features of the lowest frequency and set it to "Disabled".
– On board LAN 1/On board LAN 2
– PCI slot 1
Содержание Express5800/B120b
Страница 14: ...viii This page is intentionally left blank ...
Страница 97: ...Configuring Your Server 4 47 Property of Hard disk drive of Universal RAID Utility ...
Страница 169: ...Installing the Operating System with Express Setup 5 33 5 Select Perform the Express setup from the Top Menu click Next ...
Страница 194: ...5 58 Installing the Operating System with Express Setup This page is intentionally left blank ...
Страница 203: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear ...
Страница 224: ...7 6 Maintenance This page is intentionally left blank ...
Страница 300: ...9 38 Upgrading Your Server This page is intentionally left blank ...
Страница 302: ...A 2 Specifications This page is intentionally left blank ...
Страница 377: ...Installing the Operating System B 75 4 Activate Windows The Windows activation is complete ...
Страница 381: ...Installing the Operating System B 79 3 Process Windows activation according to the following message ...
Страница 382: ...B 80 Installing the Operating System This page is intentionally left blank ...