4-60
Disassembly and Reassembly
9.
Power on the server. The AC POWER lamps go on.
10.
Confirm, by the STATUS lamp or on the POST screen, that there are no
errors related to the power supply units.
See Chapter 5 for details on the error messages.
If the AC POWER lamps are off, reinstall the power supply units. If
the same error message still appears, contact your service
representative.
Replacing a Power Supply
Note:
If one power supply unit fails and the server contains two
power supply units in a redundant configuration, the failing power supply
unit can be replaced with the system power on. (If your server is running
in the redundant power configuration, skip Step 1 and 2 in the following
procedure.)
1.
Observe the safety and ESD precautions listed under General Information
and Static Precautions at the beginning of this chapter.
2.
Perform the steps in "Preparing Your System for Upgrade" described earlier
in this chapter
3.
Locate the failing power supply unit by the AC POWER lamp on the rear of
each power supply unit. (The lamp of the failing power supply unit is
amber.)
4.
Hold and pull the handle of the failing power supply unit. The power supply
unit is unlocked.
5.
Remove the power supply unit. See Figure 4-69.
Figure 4-69. Removing a Supply
6.
If operating the server with a single power supply unit without installing a
new one, install the blank cover.
IMPORTANT:
To maintain the cooling effect in the server, install the blank
cover in the slot not containing a power supply unit.
7.
Install the new power supply unit following the power supply installation
procedure previously described in this chapter.
Содержание EXPRESS5800/120Re-2
Страница 1: ... S e r v i c e G u i d e EXPRESS5800 120Re 2 ...
Страница 2: ...xxx ...
Страница 3: ... S e r v i c e G u i d e EXPRESS5800 120Re 2 ...
Страница 10: ...viii Contents INDEX ...
Страница 30: ......
Страница 59: ...Setting Up the System 2 29 Figure 2 34 Making Connections ...
Страница 78: ......
Страница 178: ......
Страница 200: ...5 22 Problem Solving ...
Страница 201: ...6 Illustrated Parts Breakdown Exploded View Field Replaceable Units Cable List Upgrades ...
Страница 210: ...6 10 Illustrated Parts Breakdown This page is intentionally left blank ...
Страница 211: ...A Specifications System Specifications ...
Страница 220: ......
Страница 221: ...C Interrupt Requests ...
Страница 232: ...10 Glossary ...
Страница 237: ...xx ...
Страница 238: ... 456 01599 000 ...