4-24
Dissasembly and Reassembly
Installing or Swapping a Hard Disk Drive in a Hot-Swap Bay
This procedure describes installing a new hard disk drive or swapping out a
faulty drive from one of the six hot-swap SCSI disk drive bays. The SCSI drives
must use the industry standard 80-pin Single Connector Attachment (SCA)
connector. Each drive must be installed in a drive carrier.
Note:
To order a disk with a carrier, contact the sales
representative or dealer.
!
If installing new drives, follow an installation scheme starting with the
left-most drive. Fill the bays left-to-right (1 through 6). See Figure 4-19.
0
1
2
3
4
5
1 2
3
4
5
6
A
B
Figure 4-19. SCSI Disk Drive Installation Scheme
!
The hard disk SCSI address assignment is:
Bay
Device
SCSI ID Address
1
First Hard Disk (Left)
0
2
Second Hard Disk
1
3
Third Hard Disk
2
4
Fourth Hard Disk
3
5
Fifth Hard Disk
4
6
Sixth Hard Disk (Right)
5
!
If an individual SCSI drive fault LED (yellow light) is on steadily, this
indicates that the drive has been flagged as faulty by the RAID host
controller (See Figure 4-19,A). Follow the procedure described in this
section to remove the faulty drive and swap in a good one.
Содержание EXPRESS5800/120Ld
Страница 1: ... S e r v i c e G u i d e EXPRESS5800 120Ld ...
Страница 2: ...xxx ...
Страница 3: ... S e r v i c e G u i d e EXPRESS5800 120Ld ...
Страница 10: ...viii Contents ...
Страница 50: ...2 18 Setting Up the System ...
Страница 122: ......
Страница 144: ...5 22 Problem Solving ...
Страница 155: ...A System Cabling System Cabling Before You Begin Static Precautions Standard Configuration RAID Configuration ...
Страница 162: ......
Страница 163: ...B System Status Hardware Support Information ...
Страница 178: ...C 14 Connectors ...
Страница 188: ...10 Glossary ...
Страница 193: ...xx ...
Страница 194: ... 456 01529 000 ...