![background image](http://html.mh-extra.com/html/nec/express-5800-120eh/express-5800-120eh_user-manual_251151232.webp)
9-26 Upgrading Your Server
Installation Considerations for RAID Controller
Described below must be considered when installing any of the RAID controller listed below. For
details, refer to the manual that comes with the RAID controller.
–
N8103-101 SATA2 Disk array controller
–
N8103-105 SAS Disk array controller
–
N8103-91 Disk array controller
–
N8103-99 Disk array controller (0ch)
Prepare the hard disk drives and cables appropriate to RAID controller to be installed.
Configure the Logical Settings of hard disk drive.
Prepare the number of hard disk drives required for desired RAID (Redundant Array of
Inexpensive [Independent] Disks) level.
Making hard disk drives in the disk array configuration or changing the RAID level
initializes hard disk drives. If the hard disk drive to be configured in the array has your
valuable data stored, make sure to make a backup copy of the data in another hard disk
drive before installing the disk array controller board and configuring the array.
Use hard disk drives of the same capacity and revolution for each pack to configure them
in the array.
The disk array configuration improves disk reliability but provides a smaller disk capacity
than the total capacity of hard disk drives in the disk array configuration.
When the disk array controller board is replaced, restore the disk array configuration
information in the disk array controller board. Use the configuration utility for the
restoration. Chapter 6 for details.
To indicate the access status of each hard disk drive connected to the RAID controller
with the DISK ACCESS lamp on the front panel of the server, use the LED cable that
comes with your server.
–
With N8103-101/105 disk array controller, connect the LED cable to the LED
connector on mother board and that on the RAID controller.
–
With N8103-91 disk array controller, connect the LED cable to the LED connector on
the mother board and that on the N8154-11 additional HDD cage.
Refer to the manual that comes with your RAID controller for more information.
Содержание Express 5800/120Eh
Страница 16: ...x This page is intentionally left blank ...
Страница 32: ...2 4 General Description SATA Model 1 Additional slot 1 2 3 4 5 6 10 9 7 8 Additional slot 2 11 ...
Страница 36: ...2 8 General Description Internal View SAS Model 1 2 4 5 1 6 7 8 3 2 3 1 5 2 10 9 ...
Страница 52: ...2 24 General Description This page is intentionally left blank ...
Страница 112: ...4 48 Configuring Your Server This page is intentionally left blank ...
Страница 176: ...7 12 Maintenance This page is intentionally left blank ...
Страница 234: ...9 28 Upgrading Your Server N8103 101 N8103 105 Black cable Red cable Red Black Black cable Red cable Red Black ...
Страница 235: ...Upgrading Your Server 9 29 N8154 11 Additional HDD Cage Black cable Red cable Additional HDD cage Red Black ...
Страница 338: ...E 24 Installing Windows Server 2003 This page is intentionally left blank ...
Страница 342: ...F 4 Product Configuration Record Table This page is intentionally left blank ...