![background image](http://html1.mh-extra.com/html/nec/electraelite-ipk/electraelite-ipk_installation-and-maintenance-manual_3848447019.webp)
Hardware, Installation and Maintenance Manual
3 - 1
___________________________________________________________________________________
___________________________________________________________________________________
Chapter 3
IPK IAD(8)-U( ) Programming
S
ECTION
1
S
YSTEM
P
ROGRAMMING
The IAD (8)-U10 ETU is recognized by the Electra Elite IPK system as a COI(4)/
(8)-U10 ETU, a COID(4)/(8)-U10 ETU, a DID(4)-U10 ETU, or a TLI(2)-U10 ETU, DTI
ETU based on the configuration on the ETU. This ETU takes longer to initialize than
the other Electra Elite IPK ETUs and must be programmed using Memory Block 7-1
(Card Interface Slot Assignment).
The following procedure provides the general directions for Electra Elite IPK
programming for the ETU Interface Slot Assignment.
1.
From port 01 or 02, enter the programming mode.
2.
Press
A
,
H
,
L
,
K
and
J
.
3.
Assign the Card Interface Slot Assignment by pressing LK7 and LK1.
4.
Press
A
,
B
or
C
for the cabinet number of KSU where the IAD(8)-U( )
ETU is installed.
5.
Press
L
to move the cursor to the right.
6.
Enter slot number (1~8) of the KSU containing the IAD(8)-U( ) ETU.
7.
Refer to Table 1 IAD Trunk Card Configuration and press the "line key" button
corresponding to the operating mode of the IAD(8)-U( ) ETU, for line key slot
type.
Table 3-1 IAD Trunk Card Assignment
PG/LK No.
Slot Type
PG/LK No.
Slot Type
PG1/LK 2
COI(4)-U10
PG1/LK6
COID(8)-U10
PG1/LK3
COI(8)-U10
PG1/LK7
TLI(2)-U10
PG1/LK5
COID(4)-U10
PG1/LK8
DID(4)-U10
PG6 LK1
DTI 4
PG6 LK2
DTI 8
Содержание ElectraElite IPK