CABLE TERMINATION
6-41
Installation
NWD-107460-02E
Procedure 6-9
N-P Connector used for ODU IF IN/OUT
(Straight: N416(R0))
1
Insertion of parts
The clamp nut, the washer and the gasket are inserted in the cable.
2
Remove of jacket of cable, insertion of parts,
(1) Remove 11 mm of jacket only.
(2)
The clamp1 is inserted as shown.
Note
Do not damage the braided wire.
Tools
•
knife, cutter, nipper, tweezers, file, measure,
clearance gauge, etc.
•
spanner, torque spanner; 16 mm
Tools
•
knife
•
cutter
•
measure, etc.
Outlines of parts
[
Applicable cable: 8D-FB-E]
Cable jacket
Aluminum tape
Braided wire
Insulator
Center conductor
Washer
Clamp nut
Gasket
Clamp1
Connector body
Cable
Washer
Clamp nut
Gasket
11 mm
(Clamp1)