6-8
CABLE TERMINATION
NWD-107460-02E
Installation
5
Connector assembly
(1) The cable center conductor must be straight and aligned with the connector
inner contact. Insert the cable into the connector body until stopped; the center
conductor must be inserted into the connector inner contact fingers.
(2)
Tighten the connection to the torque value of 9 to 11 N·m.
(Refer to step (a) through (e)).
(a)
Hold of cable and connector body.
Connector body
Clamp nut
Submission Prohibited