7
A
minimum clearance from rear edge of cutout to nearest combustible surface: 55
B minimum clearance from glass surface to rangehood: 650
C minimum clearance from side edges of cutout to nearest combustible surface: 80
D minimum clearance from benchtop to overhead cabinet not directly above the cooktop:
450
E
minimum clearance below top of benchtop to top of oven* installed below cooktop (see
Fig.1)thermal protection barrier (see Fig.2): 20
When you have installed the cooktop, make sure that
1.
the power supply cable is not accessible through cupboard doors or drawers
2.
there is adequate flow of fresh air from outside the cabinetry to the base of the
cooktop
3.
if the cooktop is installed above a drawer or cupboard space, a thermal protection
barrier is installed below the base of the cooktop
4.
the isolating switch is easily accessible by the customer
5.
you complete the
‘
Final checklist
’
at the end of these installation instructions.
Fig. 1
Thermal Protection Barrier
The thermal protection barrier must be:
1.
Removable
2. heat-resistant
3.
made from low thermal conductivity material
4.
at least 25 mm below the plastic housing of the cooktop chassis
Connecting the Cooktop to the Mains Power Supply
Important!
This cooktop must be connected to the mains power supply only by a
suitably qualified person.
1.
Before connecting the cooktop to the mains power supply, check that:
9
The domestic wiring system is suitable for the power drawn by the cooktop.
9
The voltage corresponds to the value given in the rating plate
9
The power supply cable sections can withstand the load specified on the rating
plate.
2.
To connect the cooktop to the mains power supply, do not use adapters, reducers, or
branching devices, as they can cause overheating and fire.
3.
The power supply cable must not touch any hot parts and must be positioned so that
its temperature will not exceed 75
℃
at any point.
Power Supply
:
Important!
Check with an electrician whether the domestic wiring system is suitable without