NDW 50 DRX Скачать руководство пользователя страница 3

NDW 

| We’ll keep you rolling | 3

NDW 

| We’ll keep you rolling | 4

Contents

This manual contains important product 
information and -specifications of the NDW 
50/60 DRX motor rollers. It provides the intended 
use, integral safety measures and guides for 
servicing, transport and storing conditions. Also 
technical support for installation, maintenance and 
troubleshooting is provided.

This guide is part of the product. Therefore, the 
product cannot be used without consulting the 
guide prior to installation or use.

General Safety Measures

The NDW 50/60 DRX has been designed and 
configured in order to meet safety standards 
when in operation. However risks may still occur. 
Therefore, it is important to study and follow the 
manual prior to usage.

• For optimal and safe use of the system 

• 

it is required to study and follow the 

• 

manual.

• Keep this manual in a safe and visual 

• 

location near the system.

• The supplier cannot be held responsible 

• 

for faults and defects due to a cause by 

• 

not following this manual.

• The supplier cannot be held responsible 

• 

when changes are made and/ or added 

• 

to the system which has not been described 

• 

and/ or allowed in the manual.

• Do not use the system when one or 

• 

more components are damaged or 

• 

malfunctioning.

• Questions concerning the manual can 

• 

be addressed to NDW located in Waalwijk

Dangers

While working with the NDW 50/60 DRX, certain 
dangers may occur. This list provides the general 
dangers that may happen and instructs on how to 
avoid accidents:

• Maintenance and repair may only be executed  

• 

by authorized and qualified personnel according  

• 

to the appropriate national safety regulations.  

• 

Otherwise serious bodily injury may arise.

• Before initiating or using the NDW 50/60 DRX,  

• 

make sure all unauthorized personnel has cleared  

• 

the working area of the conveyor.

• Make sure the NDW 50/60 DRX is only operated  

• 

with control voltages compliant with a SELV  

• 

environment.

• The power must be switched off at all times when  

• 

maintenance or installation work is performed  

• 

with the NDW 50/60 DRX. Ensure the power  

• 

cannot accidentally be switched on.

• Check for visible damage regularly. Also make  

• 

sure mounts and screws have correct tension.

• If you notice any faulty behavior of the controller  

• 

or the system, immediately cut the power and  

• 

make sure it cannot accidentally be switched on.  

• 

Contact qualified personnel in order to perform  

• 

troubleshooting.

• Make sure no unnecessary tools or equipment is  

• 

near the system when in operation. Tools or  

• 

screws falling on the conveyor may cause serious  

• 

damage to the system.

Intended use

The NDW 50/60 DRX motorrollers must only be 
used for industrial applications in an industrial, dry 
environment. The NDW 50/60 DRX motorrollers 
must be controlled by the NDW Budget-, Basic- or 
BasicPlus controllers. Any other use is prohibited. 
If external tools and machinery are integrated, it 
is required to validate the safety before using the 
system.

Qualified persons

Only qualified personnel is allowed to work with- or 
integrate the NDW 50/60 DRX. Qualified personnel 
are expected to understand this manual and have 
knowledge on national safety regulations regarding 
industrial appliances. While working with the NDW 
50/60 DRX, the following points should be taken 
into account by the qualified personnel:

• Relevant diagrams and user manuals of the NDW  

• 

50/60 DRX

• Regulations and requirements that are specific  

• 

for this product

• Safety and warning instructions as provided by  

• 

this document

• National and/or local safety regulations

INTRODUCTION

• When installing or troubleshooting the conveyor  

• 

system, be aware that sensors or other signals  

• 

may be triggered unintentionally, leading to  

• 

hazardous situations. Be sure to always turn the  

• 

power off when possible in an event of  

• 

installation or maintenance/troubleshooting. 

• Make sure to keep fingers, hair, loose clothing,  

• 

jewelry away from any moving parts.

• Don’t touch the NDW 50/60 DRX during  

• 

operation.

• Make sure the NDW 50/60 DRX can’t start up  

• 

accidentally. This is especially important during  

• 

assembly and maintenance

Содержание 50 DRX

Страница 1: ...Technical Guide NDW 50 60 DRX...

Страница 2: ...cifications and product descriptions at any time without further notice NDW is not committed to change or update the information in this document with any regard to commitment NDW products services an...

Страница 3: ...be switched off at all times when maintenance or installation work is performed with the NDW 50 60 DRX Ensure the power cannot accidentally be switched on Check for visible damage regularly Also make...

Страница 4: ...amic braking Cable length 300 mm with M8 connector 5 pins Operation at 40 C continuous 100 Operation at 40 C intermittent 1440 starts hour max Protection Minimum duty cycle 1s ON 1 5s Off ED ON ON OFF...

Страница 5: ...ox Ribbed belts 10 m min 20 m min 30 m min 40 m min 55 m min 60 m min 180 160 140 120 100 80 60 40 20 0 10 kg 20 kg 30 kg 40 kg 50 kg kg load mm lengte Steel tube MDR tube 50x1 5 mm tube 60x2 0 mm 800...

Страница 6: ...2 5 8 5 8 0 75 K 2 5 0 2 101 260 2 51 6 5 0 2 1 0 2 4 3 4 3 0 43 K 1 5 0 2 106 260 2 66 6 5 0 2 0 9 2 2 9 2 9 0 12 K 0 45 0 45 112 260 2 81 6 5 0 2 0 9 2 V m min 3 no load V m min 3 nominal Speed sel...

Страница 7: ...RX can be equipped with different belt grooves to support round belts and Poly VG belts The dimensions of the available grooves can be found below 28 80 2x Groove 44 74 mm Round beldt head 18 31 5 mm...

Страница 8: ...rly fixed Every package should be checked for damage and completeness While storing the NDW 50 60 DRXs ensure no more than four boxes are stacked on top of each other as this may result to tipping ove...

Страница 9: ...ot connect AC current to the NDW 50 60 DRX at any time as this will cause irreparable damage to the device Don t use earth wires or connections as a protective conductor The motor plug should be handl...

Страница 10: ...o regular inspection for dirt and dust is needed Disposal The disposal of the Basic controller must be compliant to industry specific national or local provisions The responsibility for right disposal...

Страница 11: ...NDW Sluisweg 32 5145 PE Waalwijk 31 0 416 67 44 44 info ndw nl www ndwrollers com...