NDUSTRIA™ Infrared Electric Manual
2
SECTION 2: INSTALLER RESPONSIBILITY
The installer is responsible for the following:
• To install the heater, as well as the electrical sup-
plies, in accordance with applicable specifi cations and
codes. NDUSTRIA recommends the installer contact a
local Building Inspector or Fire Marshal for guidance.
• To use the information given in a layout drawing and
in the manual together with the cited codes and regu-
lations to perform the installation.
• To install the heater in accordance with the clear-
ances to combustibles.
• To furnish all needed materials not furnished as
standard equipment.
• To plan location of supports.
• To provide access to heater for servicing on all
sides.
• To provide the owner with a copy of this installation,
operation and service manual.
• To never use heater as support for a ladder or other
access equipment and never hang or suspend any-
thing from heater.
• To ensure there is adequate air circulation around
the heater.
• To ensure the heater is placed in an approved ap-
plication. This heater is designed for indoor/outdoor
commercial/industrial use or outdoor residential use.
Heater is NOT approved for indoor residential use,
including, but not limited to, attached garages, living or
sleeping areas, etc. Do not use in bathrooms, laundry
areas or other locations where it could fall into water.
Consult local fi re marshal and/or insurance provider if
unsure of your application.
• To mount heaters according to mounting instructions.
It is recommended to wall mount heaters. However,
ceiling mounting is acceptable provided the following
conditions are met: DO NOT position or mount heater
other than angle specifi ed in Figure 1 and Table 1 and
18” (0.45m) from combustible ceiling.
NOTE: Appropriate rigid mounting brackets (provided
by others) are necessary.