NDT EVOTIS Скачать руководство пользователя страница 9

- 9 -

Warranty 

The product described herein is warrantied against defects in material, 
design and workmanship for a period of one year from the date of shipment 
from Japan. Warranty does not apply to the consumable parts including 
batteries, charger, and hammer head of the Auto Hammer. 

Subject to the conditions and limitations described below, this product, if 
returned to us with proof of purchase within the stated warranty period, and 
if covered under this warranty, will be repaired or replaced (with the same 
model, or one of equal value or specification) at our option. 

This warranty is subject to the following conditions and limitations: 
A) This warranty will not apply to any product or part thereof that is worn

or broken or that has become inoperative due to abuse, misuse, accidental
damage, neglect or lack of proper installation, operation or maintenance
(as outlined in the operating instructions).

B) This warranty will not apply to normal wear and tear or to expendable

parts or accessories that may be supplied with the product and that are
expected to become inoperative or unusable after a reasonable period of
use.

C) This warranty will not apply where damage is caused by repairs made or

attempted by others (i.e. persons not authorized by the manufacturer).

D) This warranty will not apply to any product or part thereof if any part

from another manufacturer is installed therein or any repairs or
alterations have been made or attempted by unauthorized persons.

E) This warranty will not apply to normal deterioration of the exterior finish,

including but not limited to scratches, dents, chipped paint, or to any
corrosion or discolouring caused by heat, abrasive and/or chemical
cleaners;

Содержание EVOTIS

Страница 1: ...EVOTIS DIGITAL ELECTRONIC TAPPING EXFOLIATION DETECTOR OPERATION MANUAL ...

Страница 2: ...presence of flammable gases or fumes Operation of any electrical instrument in such an environment constitutes a definite safety hazard Keep Away from Live Circuits Operation personnel must not remove instrument covers Component replacement and internal adjustments must be made by qualified maintenance personnel Do not replace components with the power cable connected Under certain conditions dang...

Страница 3: ...Fig 1 1 Auto Hammer with connector cable Fig 2 1 AC Adapter Fig 3 1 Dedicated USB Cable Fig 4 1 Communication Software CD ROM Fig 5 1 AA Rechargeable NiMH Batteries Fig 6 4 Battery Charger Fig 6 1 Operation Manual this document 1 Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 ...

Страница 4: ... are shown in four levels by three color LED lights and a buzzer sound at the designated ratio 2 A half wave length of the very first sound wave is collected from the hammer as a measured value and is displayed as a three digit numerical value in units of 1 micro second Patent 3922459 Measured values up to 7 700 strokes can be saved in the EVOTIS By connecting the EVOTIS with a computer using a de...

Страница 5: ...on 4 Standard Value 5 Measured Value 6 Stroke counter 7 Standard value button 8 LED lights 9 Memory button 10 Buzzer On Off button 11 Auto Hammer hub 12 PC Port hub 13 Power Button AC Adopter Hub Battery Housing Console 1 2 3 5 7 8 9 4 6 11 10 12 13 ...

Страница 6: ...e This standard value is shown on the unit s display Once a standard value is obtained the Ready lamp will light up 4 Press the Start Stop button to start measuring the testing subject Press the Start Stop button to stop operation Pressing the Start Stop button with a longer stroke allows continuous measuring of the testing subject 5 EVOTIS compares each measured value with the standard value Diff...

Страница 7: ...be converted to an electronic synthetic sound at below frequencies 020 µs 6 25 kHz Highest 050 µs 2 50 kHz 100 µs 1 25 kHz 200 µs 625 Hz 500 µs 250 Hz 999 µs 125 Hz Lowest Auto Hammer Configuration Square pole with the sides of 20mm and a height of 90mm excluding protrusion Sound collecting method Condenser microphone waterproofed Tapping Stainless steel hammer with a diameter of 10mm powered by s...

Страница 8: ...ndard value must be reset each time a different material and or difference in surface thickness is being tested 3 To avoid misreading test results the surface of the testing subject must be cleaned before operation 4 Remove batteries if the EVOTIS is not in use for an extended period Care and Cleaning Clean the surface of the case with an alcohol based substance Do NOT use any other solvents inclu...

Страница 9: ...operative due to abuse misuse accidental damage neglect or lack of proper installation operation or maintenance as outlined in the operating instructions B This warranty will not apply to normal wear and tear or to expendable parts or accessories that may be supplied with the product and that are expected to become inoperative or unusable after a reasonable period of use C This warranty will not a...

Отзывы: