signal and start monitoring the Starter battery voltage
to check the State of Charge. With a voltage higher
than
13.3V
, or
26.6V
for 24-24 versions, the
POWER
SERVICE
PSB
will start charging the leisure
batteries.
During the charging phase, the starter battery voltage
will be constantly monitored to avoid any supply
problem or overload to the alternator. If necessary, the
POWER
SERVICE
PSB
will reduce the output current or
stop the charge completely. The output current will be
limited if the
POWER
SERVICE
PSB
detects an active
signal D+ (or I) and a starter battery voltage
below 13V.
The
POWER
SERVICE
PSB
switches off completely if the
starter battery voltage drops to 12.8V and the signal D+
or I (ie engine shutdown) is no longer detected
(different thresholds for Smart Alternator Euro6).
The
AUX connection
makes installation simple and
intuitive, even with an existing electrical system: the
Control Unit, or any other appliances system, installed
on the leisure battery, can be switched to the AUX
connection without changing the wiring system. it’s
quick and easy!
POWER
SERVICE
PSB
is fitted with the new
N-BUS
communication and connection protocol
: now you
can connect and control all the allowed devices with a
simple cable, and manage them with one control only,
the
DTB01 touch screen display
. If there is a N-BUS
bluetooth device in the same network you can also use
the NDS mobile App for iOS and Android.