14.EXTERNAL FUSE
External fuses must be installed very close to the
battery poles. The characteristics of the fuse to be
purchased, depend on the Power Service PSB model.
Refer to the table below for optimal installation.
15.POWER CABLE SECTION
These are power cables:
• Connection between the Starter battery positive
terminal and Ref. A of the PSB (fig. 1).
• Connection between Leisure battery positive pole
and Ref. B of the PSB (fig. 1).
• Connection between the negative poles of the two
batteries and Ref. C of the PSB (fig. 1).
The cross-section to be chosen depends on the
POWER
SERVICE
PSB
model and also on the length of
the cables themselves.
22
PSB Model
Input fuse
(Starter battery positive
pole)
Output fuse
(Leisure battery positive
pole)
PSB 12-40
60A -
70A
50A -
60A
PSB 12-80
100A -
125A
90A -
100A
PSB 24-30
60A
40A
PSB 24-60
80A
70A -
80A
PSB 12/24-20
60A -
70A
25A -
30A
PSB 12/24-40
100A -
125A
50A -
60A
PSB 24/12-40
40A -
50A
50A -
60A
PSB 24/12-80
60A
90A -
100A
Содержание POWERSERVICEPSB PSB 12-40