DDPHCL2_man_r1.0 – 03/2021 

Page 4 

 

PACKING LIST 

The DDPHCL2 unit is supplied already wired internally, and complete with: 
1.  pH electrode with glass body, 65 cm cable and BNC connector with protective sheath  
2.  Redox electrode with platinum sensor, glass body, 65 cm cable and BNC with protective sheath 
3.  pH and redox calibration solutions, 90 ml each (pH4, pH7 and 220 mV) 
4.  Two standard kits for peristaltic pump, each one including: 

  foot filter and injection valve with ½” connections 

  PVC Crystal, 4x6 tube for suction line, 2 meters 

 

 

 

 

  semi-rigid PE, 4x6 tube for injection line, 2 meters   

 

 

 

 

5.  Screws and stoppers for wall installation  

 

 

 

 

 

 

6.  Instruction manual 
 
 
 
 

INTRODUCTION  

DDPHCL2 is a compact system easy to install (wall) and maintain, which allows to monitor and control 
the pH and redox potential levels in swimming pools. 
The DDPHCL2 system includes a digital controller which operates accordingly with the set thresholds, 
two peristaltic pumps, pH and redox electrodes with BNC connector, and down-flow probe-holder. 
 
 
 

INSTALLATION  

Warning!

 

Always  follow  the  warnings  and  general  safety  information  referred  at  the 

beginning of this manual! 

 

Install the DDPHCL2 unit away from heat sources, in a dry place protected from direct sunlight, at a 
maximum ambient temperature of 40°C.  
The minimum temperature shall be such as to ensure the solution to be dosed remains in a fluid state 
and in no case less than that declared in the “Technical specifications” section. 
The DDPHCL2 unit must be installed on a vertical wall and securely clamped. Choose a location that 
allows easy calibration operations, use and maintenance.  
Place the tanks of the products to be dosed below the pumps, without exceeding the maximum suction 
height of the pumps (about 1.5 m).  
If the system is installed below the level of the liquid to be dosed, check the condition of the injection 
valves or install appropriate anti-siphon kit. 
If the pump is placed above the tank and the reagent fumes could be especially aggressive, check the 
tank seals. 
 

Connect the connectors may be disconnected for packaging reasons to the respective inputs on the 
bottom of the unit (see the “Functional description” section for further details). 

 

 

Содержание DDPHCL2

Страница 1: ...DDPHCL2 Unit pH Chlorine Control INSTRUCTION MANUAL...

Страница 2: ...Always use original spare parts for maintenance Failure to follow instructions can cause damage to the equipment and in extreme cases to people How to ship the instrument To send back the device for r...

Страница 3: ...ONNECTIONS 9 Level Control 9 Flow Control 9 INTERNAL CONNECTIONS for technical personnel only 10 START UP 10 VISUALIZATIONS 11 OPERATION OF THE ELECTRONIC UNIT 11 Standard Configuration 11 Advanced Co...

Страница 4: ...ow probe holder INSTALLATION Warning Always follow the warnings and general safety information referred at the beginning of this manual Install the DDPHCL2 unit away from heat sources in a dry place p...

Страница 5: ...rs LCD with backlight Electrode holder down flow type transparent methacrylate body with standard connections for 8x12 tube and sampling needle Peristaltic Pumps Flow rate 1 5 l h 1 bar for pH adjustm...

Страница 6: ...acid dosage Peristaltic pump 2 for chlorine dosage Transparent methacrylate down flow type electrode holder Bottom view connections POWER Prewired power cable LEV1 Level sensor connector for acid pum...

Страница 7: ...r modifications Key Scrolls the available menus options in calibration and configuration modes decreases the displayed value Key Scrolls the available menus options in calibration and configuration mo...

Страница 8: ...he pump head 6 Locate the PVC Crystal tube inside the tank and or the suction lance 7 Unscrew the fixing nut of the foot filter 8 Cut the transparent PVC Crystal tube 9 Insert the fixing nut and the t...

Страница 9: ...el sensors one for each pump and flow sensor are available on special connectors that allow an extremely fast and easy connection even for unskilled personnel Note the pH and redox inputs should never...

Страница 10: ...nections line neutral of the power supply does not affect the normal operation If the level and flow inputs are not used leave them open not connected START UP At start up the microcontroller displays...

Страница 11: ...of fault or alarm condition the pump stops dosing until the normal working conditions are restored OPERATION OF THE ELECTRONIC UNIT To access the configuration calibration and manual mode menus press...

Страница 12: ...eresis Pump 1 0 20pH 2 00pH 0 50pH P04 Dosage Pump 1 Acidification Alkalization Acidification P05 Time Base Pump 1 if P01 ON OFF if P01 Proportional 5 30 sec 100 360 sec 60 60 sec P06 Functioning Type...

Страница 13: ...red for proportional operation this parameter indicates the time base of pump PARAMETER 06 FUNCTIONING TYPE OF THE PUMP 2 This parameter allows to set the functioning type of pump 2 typically used for...

Страница 14: ...you need to send back the unit to the factory for a complete reconfiguration out of warranty PARAMETER 17 FUNCTIONING OF THE ALARM OUTPUT This feature is not used for this unit PARAMETER 18 FLOW FUNC...

Страница 15: ...er solution contaminated or expired b electrode faulty or dead c connection cable or connector damaged If you try to calibrate the offset at a pH value too different from 7 00 the calibration is autom...

Страница 16: ...y one pump at a time can be activated CONTROL EXAMPLES Typical application in swimming pool control acidification when pH exceeds the pH value of 7 30 Refer to the List of configuration parameters and...

Страница 17: ...ns are not expired or contaminated repeat the procedure MAINTENANCE The periodic maintenance operations are essential for the proper functioning of the system and its duration in time The below advice...

Страница 18: ...utting down the system for wintering or anyway for a long period dose clean water to rinse the tube then rotate the roller holder clockwise to position it as shown in the figure pH and Redox Electrode...

Страница 19: ...d kit PVC Crystal suction hose 2 m PE delivery hose 2 m injection valve and foot filter 96000100 Spare blue front case for peristaltic pump with O ring 96000141 Transparent front cover for peristaltic...

Отзывы: