background image

DDPHCL2_man_r1.0 – 03/2021 

Page 12 

 

Advanced Configuration 

The advanced configuration mode also includes the parameters protected by password, that allow a 
complete  configuration  of  the  system.  This  mode  is  normally  accessed  only  by  authorized  technical 
personnel.  
1)  Once selected the “Advanced Configuration” 

option, press the CAL button to edit the list of 
parameters, or press ESC to return to the 
normal visualization mode  

2)  Now use the 

 

 keys to scroll the list of the available parameters 

3)  To modify the displayed parameter, press CAL; to quit the mode press ESC 
 

 
List of Configuration Parameters 

In this section are listed all the configuration parameters. 
It is recommended to fill the last column with the values set for your application. 

PAR. 

Description 

Min Value 

Max Value 

Default 

Value 

Set Value 

P01 

Functioning Type Pump 1 

ON-OFF  /  Proportional 

ON-OFF 

 

P02 

Setpoint Pump 1 

0.00pH 

14.00pH 

7.00pH 

 

P03 

Hysteresis Pump 1 

0.20pH 

2.00pH 

0.50pH 

 

P04 

Dosage Pump 1 

Acidification / Alkalization 

Acidification 

 

P05 

Time Base Pump 1 

if P01= ON-OFF 
if P01= Proportional

 

 

5% 

30 sec 

 

100% 

360 sec 

 

60% 

60 sec 

 

P06 

Functioning Type Pump 2 

ON-OFF  /  Proportional 

ON-OFF 

 

P07 

Setpoint Pump 2 

0mV 

1000mV 

750mV 

 

P08 

Hysteresis Pump 2 

20mV 

200mV 

50mV 

 

P09 

Dosage Pump 2 

Chlorination / De-chlorination 

Chlorination 

 

P10 

Time Base Pump 2 

if P06= ON-OFF 
if P06= Proportional

 

 

5% 

30 sec 

 

100% 

360 sec 

 

60% 

60 sec 

 

P11 

Alarm Pump 1 

0min 

240min 

0min 

 

P12 

Alarm Pump 2 

0min 

240min 

0min 

 

P13 

Start Delay 

0min 

60min 

0min 

 

P14 

Language 

Italiano - English 

Français - Español 

English 

 

P15 

Restore default values 

255 

 

P16 

Password 

255 

 

P17 

Alarm Functioning 

Relay NO / Relay NC 

Relay NO 

 

P18 

Flow Functioning 

Input NO / Input NC 

Input NO 

 

P19 

pH Equilibrium 

0min 

240min 

0min 

 

 

Warning

! The complete list of parameters can be accessed only from the “Advanced Configuration” 

menu,  while  the  “Standard  Configuration”  mode  allows  to  modify  only  the  parameters  that  are  not 
protected by password (highlighted in bold in the table above). 

 

 

 

A  D  V  A  N  C  E  D   

C  O  N  F  I  G  . 

C  A  L  >  Y  E  S   

 

 

E  S  C  >  N  O 

Содержание DDPHCL2

Страница 1: ...DDPHCL2 Unit pH Chlorine Control INSTRUCTION MANUAL...

Страница 2: ...Always use original spare parts for maintenance Failure to follow instructions can cause damage to the equipment and in extreme cases to people How to ship the instrument To send back the device for r...

Страница 3: ...ONNECTIONS 9 Level Control 9 Flow Control 9 INTERNAL CONNECTIONS for technical personnel only 10 START UP 10 VISUALIZATIONS 11 OPERATION OF THE ELECTRONIC UNIT 11 Standard Configuration 11 Advanced Co...

Страница 4: ...ow probe holder INSTALLATION Warning Always follow the warnings and general safety information referred at the beginning of this manual Install the DDPHCL2 unit away from heat sources in a dry place p...

Страница 5: ...rs LCD with backlight Electrode holder down flow type transparent methacrylate body with standard connections for 8x12 tube and sampling needle Peristaltic Pumps Flow rate 1 5 l h 1 bar for pH adjustm...

Страница 6: ...acid dosage Peristaltic pump 2 for chlorine dosage Transparent methacrylate down flow type electrode holder Bottom view connections POWER Prewired power cable LEV1 Level sensor connector for acid pum...

Страница 7: ...r modifications Key Scrolls the available menus options in calibration and configuration modes decreases the displayed value Key Scrolls the available menus options in calibration and configuration mo...

Страница 8: ...he pump head 6 Locate the PVC Crystal tube inside the tank and or the suction lance 7 Unscrew the fixing nut of the foot filter 8 Cut the transparent PVC Crystal tube 9 Insert the fixing nut and the t...

Страница 9: ...el sensors one for each pump and flow sensor are available on special connectors that allow an extremely fast and easy connection even for unskilled personnel Note the pH and redox inputs should never...

Страница 10: ...nections line neutral of the power supply does not affect the normal operation If the level and flow inputs are not used leave them open not connected START UP At start up the microcontroller displays...

Страница 11: ...of fault or alarm condition the pump stops dosing until the normal working conditions are restored OPERATION OF THE ELECTRONIC UNIT To access the configuration calibration and manual mode menus press...

Страница 12: ...eresis Pump 1 0 20pH 2 00pH 0 50pH P04 Dosage Pump 1 Acidification Alkalization Acidification P05 Time Base Pump 1 if P01 ON OFF if P01 Proportional 5 30 sec 100 360 sec 60 60 sec P06 Functioning Type...

Страница 13: ...red for proportional operation this parameter indicates the time base of pump PARAMETER 06 FUNCTIONING TYPE OF THE PUMP 2 This parameter allows to set the functioning type of pump 2 typically used for...

Страница 14: ...you need to send back the unit to the factory for a complete reconfiguration out of warranty PARAMETER 17 FUNCTIONING OF THE ALARM OUTPUT This feature is not used for this unit PARAMETER 18 FLOW FUNC...

Страница 15: ...er solution contaminated or expired b electrode faulty or dead c connection cable or connector damaged If you try to calibrate the offset at a pH value too different from 7 00 the calibration is autom...

Страница 16: ...y one pump at a time can be activated CONTROL EXAMPLES Typical application in swimming pool control acidification when pH exceeds the pH value of 7 30 Refer to the List of configuration parameters and...

Страница 17: ...ns are not expired or contaminated repeat the procedure MAINTENANCE The periodic maintenance operations are essential for the proper functioning of the system and its duration in time The below advice...

Страница 18: ...utting down the system for wintering or anyway for a long period dose clean water to rinse the tube then rotate the roller holder clockwise to position it as shown in the figure pH and Redox Electrode...

Страница 19: ...d kit PVC Crystal suction hose 2 m PE delivery hose 2 m injection valve and foot filter 96000100 Spare blue front case for peristaltic pump with O ring 96000141 Transparent front cover for peristaltic...

Отзывы: