4.4
Installing the Power Supply
The NCR Orderman Columbus800 terminal receives power from an external 19V or 24V power
supply.
The NCR Orderman Columbus800 terminal requires the NCR 19V or 24V power
supply that is shipped with the terminal. Use of other power supply may cause
damage to the unit. Do not connect or disconnect the 19V or 24V Power Cable from
the terminal with the AC Power Cord still connected to an AC outlet.
1. Unpack the terminal in the desired location.
2. Pivot the display toward the back.
Fig. 11: Display Pivot
3. Remove the Upper Stand Cover by pivoting it away from the stand. The cover has a simple
snap fit connection at the top.
Fig. 12: Remove Upper Stand Cover
Upper Stand Cover