2 Technical Data
2.1 Measurement Specification
Temperature range
100 to 650°C (212 to 1202°F)
Spectral response
3.5 to 4 µm
Detector
HgCdTe
Accuracy
± 0.5% of reading or ± 3°C (± 6°F) whichever is greater,
at 0 to 50°C (32 to 122°F) ambient temperature for the scanner
Repeatability
± 1°C (± 2°F)
at 0 to 50°C (32 to 122°F) ambient temperature for the scanner
Temperature resolution
0.1 K (digital interface)
Sampling rate
1024 pixel per scan line
2.2 Optical Specifications
Scan angle (FOV)
90°
Measurement resolution
170:1 (IFOV = 5.9 mrad)
1
, 90% energy
Spot detection
510:1 (IFOV = 2.0 mrad)
2
, 50% energy
Focus
infinity
2.3 Electrical Specifications
System power
100 to 240 VAC (for the system connection box)
Ethernet
TCP/IPv4 protocol 10/100 MBit/s, electrically isolated, auto-negotiation
IP address:
192.168.42.30
– default for the first scanner
192.168.42.31
– default for the second scanner
+1 for each further scanner
Alarm output
potential-free relay contacts: max. 30 V / 1 A, normally open / normally closed
2.4 Environmental Specifications
Ingress protection
IP65 (IEC529)
– for the linescanner
Ambient temperature
-40 to 50°C (-40 to 122°F),
– for scanner with housing, without cooling, no direct
sunlight
Warm-up time
20 min.
Lifetime
40,000 h MTBF (mean-time between failure), for the scanning system
1
measured at slit response at 20 Hz scan rate, pixel at focus distance
2
measured at slit response at 20 Hz scan rate, pixel at focus distance