background image

9

2.1  Product Overview

Transceivers - CC-Link Compliant (EPC-200-CC)

・ 

A dedicated transceiver for use with a wireless positioning unit.

・ 

Connectable to a PLC using the CC-Link protocol.

・ 

Able to automatically and collectively control up to 32 wireless
positioning units.

・ 

The transceiver settings can be easily configured using a PC with
the dedicated software (EPU-COM).

・ 

The DIN rail foot allows it to be easily attached to a DIN rail in a
single step.

EPC-200-CC is a remote device station equipment that supports CC-Link Ver. 2.00. 
Please note that CC-Link Ver. 1.10 is not supported.

CC-Link is a registered trademark of Mitsubishi Electric Corporation. This is an open
network for industrial use that enables communication between devices of many different
manufacturers.

Connection Example

Transceiver

EPC-200-CC

PLC

Units

EPU-220

EPU-100

Units

EPU-220

Allows up to 32 connections

PC equipment

EPU-COM

* Used for initial settings and controlling 

the product from a PC.

RS-485 cable (2-wire type)

USB cable connection

Wireless connection 

(2.4 GHz)

Wired connection

Overview

Содержание EPC-200-CC

Страница 1: ...Transceivers CC Link Compliant Instruction Manual...

Страница 2: ...s if you are considering a special use of this product Incorporate and install failsafe functions emergency stop monitoring and similar devices if using this product in equipment that could cause a se...

Страница 3: ...erminating resistor x1 1m 3 3 ft USB 2 0 cable x1 Simple Guide Instruction Manuals for Wireless Positioning Units Prepare the following manuals according to the products you have purchased All of the...

Страница 4: ...ram 13 3 Specifications 14 4 Installation and Connections 15 4 1 Installation Requirements 15 4 2 Transceiver Installation 16 4 2 1 Mounting on DIN Rail 16 4 2 2 Performing Wireless Communication Inst...

Страница 5: ...4 Contents 9 1 Japan Technical Conformity Mark 28 9 2 EU CE 29 9 3 USA FCC 30 9 4 Canada ISED 31 9 5 Korea KCC 32 9 6 Taiwan NCC 33 10 Warranty 34 Revision History 35...

Страница 6: ...party failures that occur during use other defects or damages caused by the use of this product Safety precautions in this manual are classified as indicated below in order to prevent personal damage...

Страница 7: ...ring work is performed after installation and the power supply terminal connections are properly insulated Be sure to install an external emergency stop circuit so that operation is immediately stoppe...

Страница 8: ...ing from 20 to 85 RH no condensation Check and adjust all settings before operation in order to prevent unexpected operation PROHIBITED Prohibited Actions in Order to Prevent Injury Electric Shock Fir...

Страница 9: ...e immediately shut off the power supply and do not turn it back on Do not move inspect or perform wiring work while the product power is on Do not handle flammable gas in the vicinity of the product D...

Страница 10: ...single step EPC 200 CC is a remote device station equipment that supports CC Link Ver 2 00 Please note that CC Link Ver 1 10 is not supported CC Link is a registered trademark of Mitsubishi Electric...

Страница 11: ...r DIN rail foot Used for mounting on a DIN rail Product No Serial No Speci cations CC Link settings switch Connects the 24 VDC power supply or wired unit Conformity standard Con gures the CC Link comm...

Страница 12: ...ta link is running Off Watchdog timer error ERR Red On All stations communication error L ERR Red On Update error local station Flashing Abnormal communication station Flashing Switch settings changed...

Страница 13: ...and x1 is the number in the ones place Setting range 01 to 64 00 cannot be used Default setting 01 x10 0 x1 1 2 5 CC Link Transmission Speed Setting Switch Set the transmission speed of CC Link commun...

Страница 14: ...CC Link CPU Wireless communication module RS 485 Rotary switch Station number x10 Rotary switch Station number x1 Rotary switch Baud rate Reset switch Low voltage detection circuit USB Memory Tra ceiv...

Страница 15: ...umption 30mA Host connection method PLC CC Link Ver 2 00 PC USB2 0 Maximum number of connections 32 units Units connection method Wireless 2 4 GHz wireless communication Wired RS 485 Wireless communic...

Страница 16: ...flammable gas harmful gas or near flammable materials Be sure to fully consider the installation environment as the transceivers themselves may be affected by external noise If operating units in a wi...

Страница 17: ...the DIN rail width 35 mm 1 378 in 2 Press the DIN rail foot against the DIN rail until it clicks Removal from DIN Rail 1 Use a tool such as a flathead screwdriver to pull down the DIN rail foot 2 Lift...

Страница 18: ...from the antenna axis After connecting the antenna adjust the angle of the antenna while considering the directivity of the radio waves Positioning the antenna vertically causes radio waves to readil...

Страница 19: ...ON Terminating resistor OFF Terminating resistor OFF USB cable Shield Terminal block Terminal block Terminal block 0V 0V 24V 24V DA DB DG SLD FG CA CB CS SL EPC 200 CC Terminating resistor 120 Used fo...

Страница 20: ...wire gauge AWG16 24 Connector Pinout Signal name Description CA RS 485 communication signal A CB RS 485 communication signal B CS RS 485 GND Shield 24 24VDC 0 0V SL Frame GND Shield Reserved Installa...

Страница 21: ...ead wire After the lead wire is inserted release the button to secure the wire 4 3 3 Connecting to PLC CC Link connection connector Specifications Connector Manufacturer PHOENIX CONTACT Model TFKC 2 5...

Страница 22: ...nded tightening torque 0 3 N m 2 65 lbf in Connecting the CC Link Connector to Lead Wire 1 Remove 10 mm 0 394 in of insulation coating from the Lead wire 2 While pressing the Orange button with a prec...

Страница 23: ...Mini USB Type B USB Cable Connection 1 When connecting to a PC connect the included USB connector of the USB cable to the USB port of the transceiver 2 Connect the USB connector on the other end of th...

Страница 24: ...following inspections periodically to prevent accidents 5 2 Inspection Checklist Is the power supply voltage within the specified range Is the operating environment within the specification ranges Is...

Страница 25: ...not possible Is the station number correct Set the correct station number P 12 Is the communication speed setting correct Set the correct communication speed Is the CC Link communication cable connect...

Страница 26: ...rawings EPC 200 CC Unit mm in Antenna 360 rotatable Power supply wired units connection connector CC Link connection connector 69 3 2 728 17 7 0 697 117 4 606 110 5 4 35 9 0 82 5 3 248 31 6 1 244 16 5...

Страница 27: ...require a license and specified low power radio stations radio stations that do not require a license which are used in medical electrical equipment industrial and chemical equipment and factory produ...

Страница 28: ...compliance testing by himself herself in the completed state with all parts including our products incorporated into the equipment In addition our products are for general industrial use and cannot b...

Страница 29: ...ch they will be used Only the black BK model of the Wireless Positioning Units can be used in EU List of available countries and regions Country Region Wirelss Positioning Units Transceivers EPU 220 A...

Страница 30: ...ya Bi tech Kaisha Add 1 Toko Taichi Seki City Gifu 501 3939 Japan The full text of the EU declaration of conformity is available at the following internet address https www nbk1560 com products mechat...

Страница 31: ...the equipment Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable...

Страница 32: ...omplies with Canada s ICES 003 CAN ICES 003 A NMB 003 A Detachable antenna This radio transmitter 1846A S2CTH has been approved by Innovation Science and Economic Development Canada to operate with th...

Страница 33: ...32 9 Laws and regulations 9 5 Korea KCC MSIP CRM DIG XBee S2C TH R R NbK EPU 220 EPU 220 R R NbK EPC 200 CC EPC 200 CC R R NbK EPC 210 EIP EPC 210 EIP LAN Bluetooth...

Страница 34: ...33 9 Laws and regulations 9 6 Taiwan NCC CCAB20LP1360T8 NCC LAN...

Страница 35: ...he issue related to the claim was caused by usage outside of the product specifications When the issue related to the claim was caused by fire earthquake lightning wind and flood damage salt damage ab...

Страница 36: ...35 MEMO...

Страница 37: ...36 Revision History Date ID No Revision Details Oct 2019 UM EPC200CC SU 01E First edition Apr 2021 UM EPC200CC SU 02E Second edition...

Страница 38: ...Second edition Apr 2021 UM EPC200CC SU 02E...

Отзывы: