2010-04-20
P/N: 240-0008-00-02
Copyright 2009-2010 NavWorx ®
Page 42 of 46
All rights reserved. Printed in the U.S.A.
ADS600
NOTES:
1. ALL WIRES 24 AWG OR LARGER UNLESS OTHERWISE SPECIFIED.
GROUNDING PIGTAILS MUST NOT EXCEED 4 INCHES IN LENGTH.
GNS 480 ARINC 429 #1 OUT (P5-4/24) MAY BE USED INSTEAD OF
429 #2 (P5-5/25) OUT.
2
3
P1
:
37-PIN D-SUB, MALE CONNECTOR
GNS 480 ARINC 743A Position Source
GNS 480
429 In 1B
429 In 1A
ARINC 429 Out 2B
ARINC 429 Out 2A
28
9
P5-25
P5-5
TWISTED SHIELDED TWO
CONDUCTOR SHIELD
TERMINATED TO GROUND
2
743A Time Mark In +
743A Time Mark In -
21
P1-19
P1-17
Time Mark Out +
Time Mark Out -
3
2