2010-04-20
P/N: 240-0008-00-02
Copyright 2009-2010 NavWorx ®
Page 28 of 46
All rights reserved. Printed in the U.S.A.
3.7.5.1
RS232 Altitude Encoder Input
An altitude encoder input may be provided through a RS232 serial data input (P1-7 and P1-6) to
the ADS600-B. The maintenance PC commands (see section 3.7) describe how to enable the
serial port for the Altitude Encoder Input. The baud rate for this port is also configurable via a
maintenance command.
3.7.5.2
RS232 TIS Output (Garmin portables GPSMAP® x96)
The ADS600-B may be configured to output TIS data via a RS232 serial data output (P1-6 and
P1-25) to a portable GPSMAP® display device. The maintenance PC commands (see section
3.7) describe how to enable the serial data port for the TIS Output. The baud rate for this port is
also configurable via a maintenance command.
3.7.5.3
RS422 In/Out Display
The ADS600-B may be configured to output to a display device using the RS422 serial interface
(P1-12, P-13, P1-30, and P1-31). The type of display device is configurable. The maintenance
PC commands (see section 3.7) allow the installer to select a display device, as well as, a baud
rate for the RS422 serial interface.
3.7.5.4
RS232 In/Out Display
The ADS600-B may be configured to output to a display device using the RS232 serial interface
(P1-5, P1-23, and P1-24). The type of display device is configurable. The maintenance PC
commands (see section 3.7) allow the installer to select a display device, as well as, a baud rate
for the RS232 serial interface.
3.7.5.5
RS232 Maintenance PC
The ADS600-B communicates with the maintenance PC using a RS232 serial interface (P1-3,
P1-4, and P1-22). This interface is used to view system status and to set the configuration of the
ADS600-B. The maintenance PC serial channel is fixed at 38,400 baud, 8 data, no parity, 1 stop.
3.7.5.6
ARINC429
The ADS600-B provides one ARINC 429 input and output (P1-8, P1-9, P1-27, and P1-28)
interface.
3.8
Post Installation Check
3.8.1
Maintenance PC
3.8.1.1
Using Maintenance Port with a Windows Terminal Emulator
For configuration and testing of the ADS600-B, a PC running a terminal emulator is required to
connect to the maintenance port of the ADS600-B.
With the ADS600-B powered on and the maintenance port connected to the PC terminal
emulator software, a test to determine if the emulator program is connected and working is to