background image

 

 

1-Wire interface 

no 

Number  of  outputs  of  the  “open  collector”  type  for  the  external  devices 

control 

Maximum switching current by the control outputs, mA 

 

500 

Maximum switching voltage by the control outputs, V 

48 

Built-in 3-axis accelerometer 

yes 

Maximum impact loading measured by the device, g 

Performance specifications 

Enclosure protection level 

IP54 

Maximum allowable overload during impacts, g 

24 

Storage temperature with the battery

5

 ,

o

Storage temperature without the battery, 

o

-40 … +85 

Operating temperature with the battery, 

o

Operating temperature without the battery, 

o

-40 … +85 

Temperature at which the battery is possible to charge, 

o

Maximum allowable humidity level at 35 

o

C, % 

95 

Device dimensions with connectors, mm 

102х57х22 

Device weight, kg 

0,067 

 

1.

 

If maximum operating voltage is exceeded the power protection is activated. The device continues to work, but is 

powered by the battery.  

2.

 

If GPRS operates in poor communications, peak consumption (10 ms), consumption of the device can accede 500 mA. 

3.

 

Attention!  Lithium  polymer  battery  (Li-Po)  is  used  in  the  device.  The  following  rules  must  be  observed  during  its 

operation: not to heat, keep away from sources of heat, not to throw the battery into the fire, not to expose to direct 

sunlight. The device, for power of which Li-Po battery is used, cannot be used in high humidity, high and low ambient 

temperatures. Operation is permitted under the conditions specified by the manufacturer. Not to hit, not to deform, 

not to disassemble, not to close contacts.  

4.

 

Protection against battery charge while it is overcooled or overheated.  

5.

 

When the device is stored and used outside the specified temperatures, it is recommended to turn it off and remove 

the battery from the device to avoid damage to the battery and to the device. 

 

 

 

Содержание SMART S-2420

Страница 1: ...GPS GLONASS TRACKING EQUIPMENT SMART S 2420 Operations manual Installation and connection of the device v1 0 MOSCOW 2020...

Страница 2: ...terested in constantly improvement of the manufactured products quality Please contact our technical support by email address support navtelecom ru should you have any questions or problems with the d...

Страница 3: ...et 7 1 7 Device components 9 1 8 Device interface connector 11 2 CONNECTION OF THE DEVICE 12 2 1 Installation 12 2 2 SIM card installation and operation 13 2 3 Power connection 13 2 4 Universal inputs...

Страница 4: ...passenger s safety 1 3 Operational principles The device during its operation continuously monitors the status of the connected sensors vehicle battery voltage GSM modem signal level operational capa...

Страница 5: ...7 Current consumption at 12 V voltage in operation mode on Average2 mA 80 Current consumption at 12 V voltage with turned off GLONASS and GSM modules is no more than mA 20 Maximum current consumption...

Страница 6: ...voltage is exceeded the power protection is activated The device continues to work but is powered by the battery 2 If GPRS operates in poor communications peak consumption 10 ms consumption of the de...

Страница 7: ...iniUSB connector for connection with a computer SIM card holder slot with ejector yellow button In the upper part of the device unit figure 3 there are three indicators system indicator SYS modem oper...

Страница 8: ...res 1 4 Interface cable with MiniUSB connector 1 5 Passport 1 6 Package 1 Figure 4 14 pin connector of Microfit 14 Figure 5 Interface cable with MiniUSB connector Some cases may require connection of...

Страница 9: ...gure 7 Fuel level sensor Figure 8 External LED The manufacturer reserves the right to complete the devices with equipment whose set appearance and characteristics differ from those shown in the figure...

Страница 10: ...res 9 12 1 front cover 2 fixing hole 3 system LED indicator 4 GSM LED indicator 5 GLONASS GPS LED indicator 6 14 pin connector 7 MiniUSB connector 8 SIM card 1 ejector holder 9 SIM card holder 1 exter...

Страница 11: ...Figure 11 Figure 12...

Страница 12: ...ency It allows to connect to them a wide range of different sensors for example frequency frequency from 1 Hz to 2000 Hz and analog voltage from 0 V to 31 V FLS impulse fuel consumption sensors DRL bu...

Страница 13: ...places with an ambient temperature more than 60 C for example near heating systems etc It is also prohibited to place the device in a sealed container without heat dissipation It is prohibited to inst...

Страница 14: ...chnical characteristics When voltage surges which is more than the specified ratings occur the built in overvoltage protection system will operate in the device It is strongly recommended to connect t...

Страница 15: ...measurement event become available CPU_adc R1 R2 UIN C1 U Figure 14 Connection of analog sensors 2 4 2 Discrete sensors connection The device allows to connect any type of sensors that have two stead...

Страница 16: ...algorithms for example when they are averaged at parking lots energy saving when calculating engine hours and in some other device algorithms Any input which configured for operation with a discrete...

Страница 17: ...lay of the track depends on its settings In addition to virtual sensors accelerometer is used for such functions as EcoDriving For proper operation of these functions the accelerometer must be calibra...

Страница 18: ...e If the power source is vehicle s on board network the LED must be connected through current limiting resistor Such resistor is already installed inside the lamp in the automotive LED lamps It is onl...

Страница 19: ...contacts are always marked as 30 87 and 87a The 30th pin is always in the relay Without applying voltage to the winding contacts it is permanently closed to contact 87a If a signal is applied to the...

Страница 20: ...30 85 86 87a 87 14 7 13 6 12 5 11 4 10 3 9 8 2 1 Fuse 1A GND Car battery Diode 1N4007 Fuse External device GND Figure 30 Connection diagram of the relay to the outputs of the device OUT1 and OUT2...

Страница 21: ...cond off There is a registration in the cellular network of the operator Weak signal 2 short flashes 1 second off There is a registration in the cellular network of the operator Medium quality signal...

Отзывы: