background image

2

ENG

manager

PACKAGE CONTENTS

  

 

EXTERIOR UNIT 

Three colour light communication 

 

Thermal sensor  

INTERIOR UNIT  

USER MANUAL 

Technical data: 

capacity: 1000 fingerprints

 

»

256-bit encryption 

 

»

high-speed identification 

 

»

operating temperature range: -30 ºC to +60 ºC 

 

»

(-22 ºF to +140 ºF) 

operating humidity range: to 90 % 

 

»

prints remain in the database even in case of 

 

»

interrupted power supply

latest generation thermal sensor

 

»

resolution 500 dpi 

 

»

Three color LEDs

Thermal sensor

Содержание ARX-manager

Страница 1: ...MANUAL DE USUARIO...

Страница 2: ...nical data capacity 1000 fingerprints 256 bit encryption high speed identification operating temperature range 30 C to 60 C 22 F to 140 F operating humidity range to 90 prints remain in the database e...

Страница 3: ...eir finger over the sensor at this height The exterior unit should be protected from rain and should not be exposed to direct sunlight 1 2 INTERIOR UNIT MOUNTING The interior unit fits on the DIN rail...

Страница 4: ...enrolled 3 DEVICE MANAGEMENT 3 1 PROPER USE ThethermalsensorusedintheARX managerenables excellent fingerprint scanning in any conditions and simultaneously minimizes the chances of misuse Nevertheless...

Страница 5: ...device is secured and for any subsequent connections one of the administrator fingerprints will have to be used You can add new fingerprints to the existing administrator or enrol a new administrator...

Страница 6: ...oose a date after which the user will be automatically deleted from the device or you can also leave this option blank By pressing add the enrolment process is started and the user swipes their finger...

Страница 7: ...rent purposes Connect your mobile device to the ARX manager In the menu select options and then choose history A page with a list of the last 100 events will open with the most recent events on the to...

Страница 8: ...n and the fingerprint database will be copied to the reader but it will remain locked A message will be displayed saying swipe your finger Then one of the administrators has to swipe their finger over...

Страница 9: ...flashes continuous ARX manager is connected to the mobile device and ready to be managed Green Yes flashes 1 x 1 x 1 s Administrator or user has been successfully identified The fingerprint template...

Страница 10: ...f the finger has not been swiped the ARX manager will return to the previous function after fifteen seconds If the enrolment procedure has not been carried out in less than one minute the device will...

Страница 11: ...in freescan mode The database is full A new fingerprint can be enrolled when some of the existing fingerprints in the database are deleted A fingerprint stored in the database is not identified The f...

Страница 12: ...nded for the time the product was at service If the respective product has undergone a major service intervention or if the product was replaced a new warranty is issued to the customer for a 24 month...

Страница 13: ...of the customer Adress of the customer Stamp and signature of the seller ARX manager was manufactured by NAVKOM d o o Prijateljeva 24 1000 Ljubljana Slovenia EU info navkom si www navkom si Product ty...

Страница 14: ...is cable is close to other high power cables Maximum length of cable between exterior and interior unit is 150 m Three connection wires between exterior and interior unit are marked 1 12 positive pole...

Страница 15: ...onnection with exterior unit 3 12 V Connection with exterior unit 4 12 V Can be used for el Lock or pushbutton 5 Connection for pushbutton With this pushbutton we trigger relay number 1 6 Contact of r...

Страница 16: ...supplied with power from interior unit We can supply power to the electric lock from interior unit only if it s consumption is less than 500 mA If electric lock has higher consumption than 500 mA we n...

Страница 17: ...lock from interior unit only if it s consumption is less than 500 mA If electric lock has higher consumption than 500 mA we need to connect additional power supply look diagram 4 As option we can conn...

Страница 18: ...ock In this case we need to connect push button for exit Only relay 1 is triggered with this button Because magnet has higher consumption than 500 mA additional power supply is required Diagram 3 ADDI...

Страница 19: ...higher consumption than 500 mA additional power supply is required If we connect 2 readers and 2 electric locks we can use the same way of connection We use this diagram also if we use 1 reader and 1...

Страница 20: ...Cesta v Log 19 1351 Brezovica Slovenija DISTRIBUIDOR AUTORIZADO AFB DOMOTICS S L C Garcilaso 213 2 1 08027 Barcelona Spain 34 934 081 741 www afbdomotics com...