22
1 DIAGNOSTIC TROUBLESHOOTING PROCEDURES
SPN
FMI
Sub-section
Condition Description
5743
11
SCR (page 1907)
SCR Thermocouple Controller signal erratic, intermittent, or
incorrect
5743
16
SCR (page 1907)
SCR Thermocouple Controller above Maximum Temperature
5743
19
SCR (page 1907)
SCR Temperature module not detect J1939
5745
3
DEFSMH (page 508)
DEF Supply Module Heater Out of Range HIGH
5745
4
DEFSMH (page 508)
DEF Supply Module Heater Out of Range LOW
5745
18
DEFSMH (page 508)
DEF Dosing Unit Heater below Warning Temperature
5746
3
DEF: SMH Relay (page 782)
DEF Supply Module Heater Relay short to PWR
5746
4
DEF: SMH Relay (page 782)
DEF Supply Module Heater Relay short to GND
5798
2
DEFSMH (page 508)
DEF Supply Module Heater Temperature erratic, intermittent
or incorrect
5798
10
DEFSMH (page 508)
DEF Supply Module Heater Temperature abnormal rate of
change
520668
31
DEF (page 497)
Controller Adaptation Outer Limits Reached (Low Reductant
Delivery)
520669
31
DEF (page 497)
Controller Adaptation Inner Limits Reached (Low Reductant
Delivery)
Figure 1
Warning Lamps
Содержание N9
Страница 2: ......
Страница 4: ...II DIAGNOSTIC MANUAL...
Страница 10: ...6 DIAGNOSTIC MANUAL...
Страница 14: ...10 1 DIAGNOSTIC TROUBLESHOOTING PROCEDURES...
Страница 42: ...38 1 DIAGNOSTIC TROUBLESHOOTING PROCEDURES 6 0 Cooling System Operational Checkout Procedure...
Страница 43: ...1 DIAGNOSTIC TROUBLESHOOTING PROCEDURES 39 7 0 Lube Oil System Operational Checkout Procedure...
Страница 51: ......